Literature DB >> 24218599

Motionless phase stepping in X-ray phase contrast imaging with a compact source.

Houxun Miao1, Lei Chen, Eric E Bennett, Nick M Adamo, Andrew A Gomella, Alexa M DeLuca, Ajay Patel, Nicole Y Morgan, Han Wen.   

Abstract

X-ray phase contrast imaging offers a way to visualize the internal structures of an object without the need to deposit significant radiation, and thereby alleviate the main concern in X-ray diagnostic imaging procedures today. Grating-based differential phase contrast imaging techniques are compatible with compact X-ray sources, which is a key requirement for the majority of clinical X-ray modalities. However, these methods are substantially limited by the need for mechanical phase stepping. We describe an electromagnetic phase-stepping method that eliminates mechanical motion, thus removing the constraints in speed, accuracy, and flexibility. The method is broadly applicable to both projection and tomography imaging modes. The transition from mechanical to electromagnetic scanning should greatly facilitate the translation of X-ray phase contrast techniques into mainstream applications.

Keywords:  CT; X-ray diffraction; radiography; retrospective phase stepping; tomosynthesis

Mesh:

Year:  2013        PMID: 24218599      PMCID: PMC3845166          DOI: 10.1073/pnas.1311053110

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  22 in total

1.  Trimodal low-dose X-ray tomography.

Authors:  I Zanette; M Bech; A Rack; G Le Duc; P Tafforeau; C David; J Mohr; F Pfeiffer; T Weitkamp
Journal:  Proc Natl Acad Sci U S A       Date:  2012-06-13       Impact factor: 11.205

2.  Fractional Talbot imaging of phase gratings with hard x rays.

Authors:  P Cloetens; J P Guigay; C De Martino; J Baruchel; M Schlenker
Journal:  Opt Lett       Date:  1997-07-15       Impact factor: 3.776

3.  Phase-sensitive imaging and phase tomography using X-ray interferometers.

Authors:  Atsushi Momose
Journal:  Opt Express       Date:  2003-09-22       Impact factor: 3.894

4.  Experimental results from a preclinical X-ray phase-contrast CT scanner.

Authors:  Arne Tapfer; Martin Bech; Astrid Velroyen; Jan Meiser; Jürgen Mohr; Marco Walter; Joachim Schulz; Bart Pauwels; Peter Bruyndonckx; Xuan Liu; Alexander Sasov; Franz Pfeiffer
Journal:  Proc Natl Acad Sci U S A       Date:  2012-09-10       Impact factor: 11.205

5.  High-speed X-ray phase imaging and X-ray phase tomography with Talbot interferometer and white synchrotron radiation.

Authors:  Atsushi Momose; Wataru Yashiro; Hirohide Maikusa; Yoshihiro Takeda
Journal:  Opt Express       Date:  2009-07-20       Impact factor: 3.894

6.  Digital wavefront measuring interferometer for testing optical surfaces and lenses.

Authors:  J H Bruning; D R Herriott; J E Gallagher; D P Rosenfeld; A D White; D J Brangaccio
Journal:  Appl Opt       Date:  1974-11-01       Impact factor: 1.980

7.  Two-dimensional gratings-based phase-contrast imaging using a conventional x-ray tube.

Authors:  Genta Sato; Takeshi Kondoh; Hidenosuke Itoh; Soichiro Handa; Kimiaki Yamaguchi; Takashi Nakamura; Kentaro Nagai; Chidane Ouchi; Takayuki Teshima; Yutaka Setomoto; Toru Den
Journal:  Opt Lett       Date:  2011-09-15       Impact factor: 3.776

8.  Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010.

Authors:  Rebecca Smith-Bindman; Diana L Miglioretti; Eric Johnson; Choonsik Lee; Heather Spencer Feigelson; Michael Flynn; Robert T Greenlee; Randell L Kruger; Mark C Hornbrook; Douglas Roblin; Leif I Solberg; Nicholas Vanneman; Sheila Weinmann; Andrew E Williams
Journal:  JAMA       Date:  2012-06-13       Impact factor: 56.272

9.  Fabrication of 200 nanometer period centimeter area hard x-ray absorption gratings by multilayer deposition.

Authors:  S K Lynch; C Liu; N Y Morgan; X Xiao; A A Gomella; D Mazilu; E E Bennett; L Assoufid; F de Carlo; H Wen
Journal:  J Micromech Microeng       Date:  2012-08-23       Impact factor: 1.881

10.  Flexible retrospective phase stepping in x-ray scatter correction and phase contrast imaging using structured illumination.

Authors:  Han Wen; Houxun Miao; Eric E Bennett; Nick M Adamo; Lei Chen
Journal:  PLoS One       Date:  2013-10-31       Impact factor: 3.240

View more
  13 in total

1.  X-ray microtomography using correlation of near-field speckles for material characterization.

Authors:  Irene Zanette; Marie-Christine Zdora; Tunhe Zhou; Anna Burvall; Daniel H Larsson; Pierre Thibault; Hans M Hertz; Franz Pfeiffer
Journal:  Proc Natl Acad Sci U S A       Date:  2015-09-30       Impact factor: 11.205

2.  Fast acquisition with seamless stage translation (FASST) for a trimodal x-ray breast imaging system.

Authors:  Ran Zhang; Amy M Fowler; Lee G Wilke; Frederick Kelcz; John W Garrett; Guang-Hong Chen; Ke Li
Journal:  Med Phys       Date:  2020-06-23       Impact factor: 4.071

3.  Motionless electromagnetic phase stepping versus mechanical phase stepping in x-ray phase-contrast imaging with a compact source.

Authors:  Katherine J Harmon; Houxun Miao; Andrew A Gomella; Eric E Bennett; Barbara A Foster; Priya Bhandarkar; Han Wen
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

4.  X-ray bi-prism interferometry-A design study of proposed novel hardware.

Authors:  Grant T Gullberg; Uttam Shrestha; Sally Ji Who Kim; Youngho Seo; Michael Fuller
Journal:  Med Phys       Date:  2021-10-11       Impact factor: 4.506

5.  Diagnosis of breast cancer based on microcalcifications using grating-based phase contrast CT.

Authors:  Xinbin Li; Hewei Gao; Zhiqiang Chen; Li Zhang; Xiaohua Zhu; Shengping Wang; Weijun Peng
Journal:  Eur Radiol       Date:  2018-01-26       Impact factor: 5.315

6.  AHA classification of coronary and carotid atherosclerotic plaques by grating-based phase-contrast computed tomography.

Authors:  Holger Hetterich; Nicole Webber; Marian Willner; Julia Herzen; Lorenz Birnbacher; Alexander Hipp; Mathias Marschner; Sigrid D Auweter; Christopher Habbel; Ulrich Schüller; Fabian Bamberg; Birgit Ertl-Wagner; Franz Pfeiffer; Tobias Saam
Journal:  Eur Radiol       Date:  2015-12-17       Impact factor: 5.315

7.  Enhancing Tabletop X-Ray Phase Contrast Imaging with Nano-Fabrication.

Authors:  Houxun Miao; Andrew A Gomella; Katherine J Harmon; Eric E Bennett; Nicholas Chedid; Sami Znati; Alireza Panna; Barbara A Foster; Priya Bhandarkar; Han Wen
Journal:  Sci Rep       Date:  2015-08-28       Impact factor: 4.379

8.  Efficient decoding of 2D structured illumination with linear phase stepping in X-ray phase contrast and dark-field imaging.

Authors:  Katherine J Harmon; Eric E Bennett; Andrew A Gomella; Han Wen
Journal:  PLoS One       Date:  2014-01-28       Impact factor: 3.240

9.  Fabrication of 200 nm period hard X-ray phase gratings.

Authors:  Houxun Miao; Andrew A Gomella; Nicholas Chedid; Lei Chen; Han Wen
Journal:  Nano Lett       Date:  2014-05-27       Impact factor: 11.189

10.  High-resolution multicontrast tomography with an X-ray microarray anode-structured target source.

Authors:  Guibin Zan; Sheraz Gul; Jin Zhang; Wei Zhao; Sylvia Lewis; David J Vine; Yijin Liu; Piero Pianetta; Wenbing Yun
Journal:  Proc Natl Acad Sci U S A       Date:  2021-06-22       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.