ABSTRACT: To investigate the usefulness of 123I-BMIPP/201TlCl scintigraphy for evaluating the presence of myocarditis in patients with polymyositis (PM) or dermatomyositis (DM).We performed a retrospective study of 26 patients diagnosed with new-onset active PM/DM who underwent 123I-BMIPP/201TlCl scintigraphy between 01 April 2010 and 20 March 2015. We determined the 123I-BMIPP/201TlCl ratio and grouped the patients according to presence or absence of a mismatch. We evaluated the relationship between mismatch and the laboratory and echocardiographic findings.Mismatch was found in 13 (50%) patients. There was no statistically significant difference in age, cardiac troponin T, myoglobin, myosin light chain, aldolase levels, E wave/A wave ratio, right ventricular systolic pressure between the mismatch and non-mismatch groups. Left ventricular end-diastolic and end-systolic dimensions were significantly greater in the mismatch group (45.0 vs 42.5 mm, P = < .01 and 29.5 mm vs 25.0 mm, P < .01). Left ventricular ejection fraction was significantly lower in the mismatch group (63.5% vs 71.5%, P = .04). Significant inverse correlation (r = -0.44, P = .03) was observed between left ventricular ejection fraction and mismatch ratio.The use of 123I-BMIPP/ 201TlCl scintigraphy may be considered for evaluating myocarditis in patients with PM/DM.Entities:
Mesh:
Substances:
Year: 2021 PMID: 34516513 PMCID: PMC8428709 DOI: 10.1097/MD.0000000000027173
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.817
Figure 1123I-BMIPP/201TlCl scintigraphy images reveal no mismatch in 123I-BMIPP and 201TlCl uptake.
Figure 2123I-BMIPP/201TlCl scintigraphy images reveal mismatch in 123I-BMIPP and 201TlCl uptake.
Patient characteristics.
| n | ||
| Age (yrs) | 53.3 ± 15.3 | |
| Sex (m/f) | 3/23 | |
| Scintigraphy mismatch (%) | 26 | 2.6 ± 5.9 |
| End-diastolic dimension (mm) | 24 | 43.9 ± 3.5 |
| End-systolic dimension (mm) | 24 | 27.3 ± 3.2 |
| Ejection fraction (%) | 24 | 67.8 ± 5.7 |
| E/A | 23 | 0.9 ± 0.4 |
| DCT | 22 | 210 ± 56.4 |
| Right ventricular systolic pressure (mm Hg) | 23 | 26.2 ± 7.4 |
| Troponin T (ng/mL) | 19 | 0.09 ± 0.11 |
| Myoglobin (ng/mL) | 17 | 469.7 ± 595.4 |
| Myosin light chain (ng/mL) | 23 | 46 ± 66.6 |
| Aldolase (IU/L) | 21 | 23.1 ± 21.5 |
Figure 3Cardiac end-diastolic dimensions in the non-mismatch and mismatch groups.
Figure 4Cardiac end-systolic dimensions in the non-mismatch and mismatch groups.
Figure 5Cardiac ejection fraction in the non-mismatch and mismatch groups.
Figure 6Scatterplot and regression line showing the correlation between left ventricular ejection fraction and mismatch ratio.
Results of 123I-BMIPP/201TlCl mismatch analysis.
| n | Non-mismatch group (n = 13) | Mismatch group (n = 13) | ||
| Age (yrs) | 26 | 58 | 51 | n.s. |
| Scintigraphic mismatch ratio (%) | 26 | 0 | 2.00 | <.01 |
| End-diastolic dimension (mm) | 24 | 42.5 | 45.0 | .01 |
| End-systolic dimension (mm) | 24 | 25.0 | 29.5 | <.01 |
| Ejection fraction (%) | 24 | 71.5 | 63.5 | .04 |
| E/A | 23 | 0.75 | 0.77 | n.s. |
| DCT | 22 | 198 | 204 | n.s |
| Right ventricular systolic pressure (mm Hg) | 23 | 24.3 | 25.1 | n.s. |
| Troponin T (ng/mL) | 19 | 0.09 | 0.11 | n.s. |
| Myoglobin (ng/mL) | 17 | 159.0 | 437.5 | n.s. |
| Myosin light chain (ng/mL) | 23 | 27.8 | 9.10 | n.s. |
| Aldolase (IU/L) | 21 | 16.0 | 10.1 | n.s. |