Literature DB >> 34515695

Continuous and automated slug flow nanoextraction for rapid partition coefficient measurement.

Emory M Payne1, Shane S Wells1, Robert T Kennedy1.   

Abstract

Octanol-water partition coefficients (log Kow) are widely used in pharmaceutical and environmental chemistry to assess the lipophilicity of compounds. Traditionally log Kow is determined using a shake-flask method that uses milliliters of sample and solvent and requires hours for preparation, extraction, and analysis. Here, we report an automated system for rapid log Kow determination for an array of compounds using slug flow nanoextraction (SFNE) enabled by a microfluidic chip. In the method, an autosampler is used to introduce 1 μL of sample into a microfluidic device that segments the injected volume into a series of 4 nL slugs that are each paired to an adjacent octanol slug. Each octanol-water phase pair is compartmentalized by an immiscible fluorous carrier fluid. During flow, rapid extraction occurs at each octanol-water interface. The resulting linear array of slugs flows into an online UV absorbance detector that is used to determine concentrations in the phases, allowing the log Kow to be measured. The microfluidic device allows toggling between two-phase "aqueous plug" generation (aqueous sample separated by fluorous carrier fluid) and three-phase "phase pair" generation. In this way, online calibration for detection in the aqueous phase can be achieved. The method is applied to determining log Kow for a panel of seven pharmaceutical compounds, including complete calibration curves, at three different pHs in under 2 h using 5 μL of extraction standard and 2.9 μL of octanol per extraction standard analyzed.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 34515695      PMCID: PMC8442929          DOI: 10.1039/d1an01156a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   5.227


  37 in total

1.  Interfacial stabilization of organic-aqueous two-phase microflows for a miniaturized DNA extraction module.

Authors:  Varun Reddy; Jeffrey D Zahn
Journal:  J Colloid Interface Sci       Date:  2005-06-01       Impact factor: 8.128

2.  Partition coefficient measurements in picoliter drops using a segmented flow microfluidic device.

Authors:  Nathan A Marine; Steven A Klein; Jonathan D Posner
Journal:  Anal Chem       Date:  2009-02-15       Impact factor: 6.986

3.  Advancing liquid/liquid extraction through a novel microfluidic device: theory, instrumentation and applications in gas chromatography.

Authors:  Daniela Peroni; Wil van Egmond; Wim Th Kok; Hans-Gerd Janssen
Journal:  J Chromatogr A       Date:  2011-08-07       Impact factor: 4.759

Review 4.  Setup and validation of shake-flask procedures for the determination of partition coefficients (logD) from low drug amounts.

Authors:  Axel Andrés; Martí Rosés; Clara Ràfols; Elisabeth Bosch; Sonia Espinosa; Víctor Segarra; Josep M Huerta
Journal:  Eur J Pharm Sci       Date:  2015-05-09       Impact factor: 4.384

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Rapid determination of logarithmic partition coefficients between n-octanol and water using micellar electrokinetic capillary chromatography.

Authors:  J T Smith; D V Vinjamoori
Journal:  J Chromatogr B Biomed Appl       Date:  1995-07-07

7.  Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique.

Authors:  Hong Chen; Qun Fang; Xue-Feng Yin; Zhao-Lun Fang
Journal:  Lab Chip       Date:  2005-04-26       Impact factor: 6.799

8.  Controlling nonspecific protein adsorption in a plug-based microfluidic system by controlling interfacial chemistry using fluorous-phase surfactants.

Authors:  L Spencer Roach; Helen Song; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2005-02-01       Impact factor: 6.986

Review 9.  In silico prediction of drug-binding strengths to human serum albumin.

Authors:  Gonzalo Colmenarejo
Journal:  Med Res Rev       Date:  2003-05       Impact factor: 12.944

10.  Controlled synthesis of nonspherical microparticles using microfluidics.

Authors:  Dhananjay Dendukuri; Kim Tsoi; T Alan Hatton; Patrick S Doyle
Journal:  Langmuir       Date:  2005-03-15       Impact factor: 3.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.