Long-term follow-up of perianchor cyst formation after rotator cuff repair.

Douglas Matijakovich1, David Solomon1, Carlos L Benitez2, Hsin-Hui Huang3, Jashvant Poeran3, Natalie Berger4, Amir Lebaschi5, Aruna Seneviratne1.   

Abstract

BACKGROUND: Perianchor cyst formation (PCF) can occur after arthroscopic rotator cuff repair with poly-L-lactic acid (PLLA) anchors; however, little is known about PCF after all-suture anchor (ASA) use.
METHODS: We reviewed patients who underwent double-row arthroscopic rotator cuff repair from 2012 to 2017 with ASAs implanted in the medial row and PLLA anchors in the lateral row. We evaluated PCF (graded on magnetic resonance imaging) and compared physical examination and functional surveys between patients with PCF (WC) and without PCF (WoC) at long-term follow-up.
RESULTS: Among twenty-two patients (23 shoulders), 93% of PLLA anchors (vs. 79% ASA) displayed a grade 0 PCF, P = .100. No PLLA anchors had a grade 3 or 4 PCF, compared to 11% of ASAs, P = .158. At a mean postoperative follow-up time of 113 weeks, there was no significant difference between WC and WoC cohorts with regard to range of motion, rotator cuff strength, American Shoulder and Elbow Surgeons survey scores, or retear rates. However, the WoC cohort had a significantly higher University of California at Los Angeles shoulder survey score at final follow-up (34.3 WoC vs. 30.9 WC, P = .024).
CONCLUSION: No difference was found in PCF between ASAs and PLLA anchors. At long-term follow-up, WoC patients had significantly improved functional outcome scores, based on the University of California at Los Angeles survey, but equivalent range of motion and rotator cuff strength examinations compared with WC patients.
© 2021 The Authors.

Entities:  

Keywords:  ASA; Anchor; PLLA; Perianchor cyst; Rotator cuff; Shoulder

Year:  2021        PMID: 34505097      PMCID: PMC8411048          DOI: 10.1016/j.jseint.2021.05.010

Source DB:  PubMed          Journal:  JSES Int        ISSN: 2666-6383


Rotator cuff tears are common in the American population with a prevalence of 22.1%, and this percentage increases with age. For those who undergo arthroscopic rotator cuff repair, the trend has been to use bone anchors in a double-row technique to reattach the tendon to the humeral head to decrease gap formation and improve healing.,,,,, There are several types of anchors available for the surgeon to use, each with different biologic and mechanical properties. Metallic and nonbioabsorbable anchors were historically used and were found to cause microscopic metallic fragments, interference with postoperative imaging, migration and cartilage damage. Newer biocomposite anchors, such as poly-L-lactic acid (PLLA) anchors coated in hydroxyappetite, became available for rotator cuff repairs; however, perianchor cyst formation (PCF) has been reported in up to 37% of PLLA anchors. The use of biologically inert anchors, such as screw-type anchors made of polyetheretherketone (PEEK) and all suture anchors (ASAs), have been developed with the goal of reducing the bone reaction, thereby improving the milieu for tendon to bone healing. ASAs are gaining favor for their biologically inert properties, small drill hole needed for implanting the anchors, and equivalent pullout strengths compared with traditional solid-body anchors. To our knowledge, there are limited data for investigating the incidence of PCF in a double row repair model comparing ASAs and bioabsorbable anchors within the same patient. Additionally, only few studies have explored the impact of PCF on clinical outcomes in the past two years.,, This study aimed to investigate PCF in patients who underwent arthroscopic double row, rotator cuff repair using Iconix ASAs for the medial row (Stryker, San Jose, CA) and biocomposite SwiveLock lateral row anchors (Arthrex, Naples, FL). Furthermore, the goal was to evaluate the impact of PCF on clinical outcomes. We hypothesized that ASAs would have fewer PCF and of lower grade than PLLA anchors, due to them being biologically inert. Additionally, we hypothesized there would be no difference in clinical outcomes between patients who had at least one PCF and patients without any PCF.

Methods

This is an institutional review board–approved cohort study performed at a single institution. Patients included in this study had a rotator cuff tear diagnosed by magnetic resonance imaging (MRI) and underwent arthroscopic rotator cuff repair by a single surgeon with a suture-bridge double-row repair using ASAs in the medial row and PLLA biocomposite anchors in the lateral row from September 2013 to November 2017 (Fig. 1). The ASAs were composed of three strands of #2 ForceFiber (Stryker, ultra-high-molecular-weight polyethylene, polypropylene, and nylon). The PLLA biocomposite anchor was composed of PLLA and tri-calcium phosphate. Beginning in June 2017, all patients were prospectively enrolled and completed a postoperative MRI. Exclusion criteria included patients with anchors other than ASA or PLLA anchors, prior surgery on the ipsilateral shoulder, single-row repair, patients without postoperative MRIs, and follow-up of less than 6 months. All patients received physical examinations at their follow-up visits and received a noncontrast MRI of the postoperative shoulder to determine the presence and size of the cyst. The final physical examination before the postoperative MRI was documented. A single, fellowship-trained musculoskeletal radiologist with 20 years of experience graded the MRI anchor cysts. Cyst formation was graded according to a previously established grading system: 0, no fluid; 1, minimal linear fluid collection; 2, local collection of fluid at the anchor insertion site; 3, fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter; and 4, fluid diameter ≥ twice the anchor diameter. The initial analysis compared PCF between ASAs and PLLA anchors. In each patient, the individual anchors and the corresponding occurrence of a cyst at the medial and lateral sides were recorded. A second analysis compared shoulders without cyst formation (WoC) to patients with at least one anchor with a ≥grade 1 PCF (WC). The primary outcomes were postoperative cyst formation and grade of cyst. Secondary outcomes included final range of motion (forward flexion [FF], external rotation (ER), internal rotation [IR]), strength 0-5 (supraspinatus, infraspinatus), re-tear rates, and functional scores as determined by the University of California at Los Angeles (UCLA) shoulder survey (Fig. 2) and the American Shoulder and Elbow Surgeons (ASES) survey., Patients’ age, gender, body mass index, smoking status, and presence of diabetes mellitus at the time of surgery were recorded. Mean duration of time between surgery and postoperative MRI, as well as between surgery and the last follow-up visit, was evaluated.
Figure 1

Flow diagram of study participants.

Figure 2

University of California at Los Angeles (UCLA) shoulder survey.

Flow diagram of study participants. University of California at Los Angeles (UCLA) shoulder survey.

Surgical technique

All patients received a preoperative interscalene block. Surgery was performed with patients in the beach chair position using standard posterior and anterior portals. Diagnostic arthroscopy was performed. The rotator cuff tear was visualized, and a subacromial decompression was performed by resecting the coracoacromial ligament, performing an acromioplasty, and removing the subacromial bursa. A subacromial decompression was not performed in patients who demonstrated a massive rotator cuff tear to preserve the coracoacromial ligament. After establishing rotator cuff tear anatomy and mobility, the cuff edge was debrided, and the greater and lesser tuberosities were prepared with a 5.5-mm motorized shaver. All medial row anchors were Iconix 2.3-mm double loaded suture anchors and placed at the articular margin of the rotator cuff footprint using the Iconix 2.3-mm drill. Sutures were passed through the rotator cuff in a mattress fashion and tied medially using a modified Weston knot. The medial row sutures were then linked to lateral row anchors (biocomposite SwiveLock 4.75 mm). One limb of suture from the posterior anchor and one limb from the anterior anchor were loaded into the SwiveLock anchor. A punch was used to create a hole in the tuberosity, and the anchor was inserted. The sutures were tensioned to compress the tendon onto the tuberosity, and the anchor was screwed into the bone. An articular margin repair was documented from the glenohumeral side. Postoperatively, a sling was maintained for six weeks. Passive motion with pendulums and supine FF was permitted during the first six weeks. Formal physical therapy was started at six weeks and continued for 18 weeks.

MRI technique

MR images were obtained using a GE Medical Systems 1.5 Tesla magnet (Optima 450w) and a receiving phased array shoulder coil. Multiplanar pulse sequences included high-resolution proton density and fat-suppressed T2-weighed fast spin echo images as well as short TI inversion recovery images to suppress any susceptibility artifact produced by the anchors. Proton density images offered the best spatial resolution with a frequency/phase acquisition matrix of 416/256. T2-weighted fast spin echo and short TI inversion recovery sequences allowed for fluid-tissue contrast to evaluate for cyst formation and had matrices of 320/256 and 288/224, respectively. All images had a slice thickness of 3 mm with a 1-mm gap.

Statistical analysis

Baseline patient characteristics were summarized using standard descriptive statistics: mean, minimum, maximum, and standard deviation (SD) for the continuous variables; and frequency and percent for the categorical variables. Differences in the characteristics between WoC and WC cohorts were tested using the Wilcoxon Mann-Whitney test for the continuous variables and Fisher’s exact test for the categorical variables. The proportions of PCF between the medial and lateral sides were calculated and compared using mixed Poisson regression models. This approach accounts for the fact that incidence of PCF is assessed in a double row repair model comparing both ASAs and PLLA anchors within the same patient; this is in contrast to a more simplistic approach that does not account for placement of ASAs and PLLA anchors within the same patient, for example, a McNemar’s paired test. The point estimates and their corresponding 95% confidence intervals were calculated. The statistical tests were two-sided at a significance level of 0.05. The analyses were performed using the SAS/STAT software, version 9.4, of the SAS System for Windows (copyright 2016 SAS Institute Inc.).

Results

A total of 22 patients (23 shoulders) met inclusion criteria in the study. Patient demographics are listed in Table I. No difference was found between WoC and WC cohorts with regard to age, gender, body mass index, smoking status, and presence of diabetes mellitus. There were 58 ASAs in the medial row and 44 PLLA anchors in the lateral row. Forty-one of 44 (93.2%) PLLA anchors had no PCF compared with 46 of 58 (79.3%) ASAs (confidence interval 0.82-11.25, P = .100). In patients who had a PCF, there was no significant difference in the grade of cyst between ASA and PLLA anchors. The total number of PCF for each grade is reported in Table II.
Table I

Characteristics of study patients.

CharacteristicWoC (n = 12)WC (n = 11)P value
Age, yr62.6 (43-79)57.1 (47-67).515
Gender, male/female3 (25)/9 (75)6 (55)/5 (45).214
BMI26.8 (23-31)29 (23.6-36.7).280
Smoker, no/yes11 (92)/1 (8)11 (100)/0 (0)1.000
Diabetes, no/yes11 (92)/1 (8)7 (64)/4 (36).155
Time between surgery and postop MRI (wks)111.5 (53.4-193.7)121.3 (42.4-208.7).786
Time between surgery and last follow-up (wks)110.7 (48-180)116.4 (40-192).705

WoC, without cyst; WC, with cyst; BMI, body mass index; MRI, magnetic resonance imaging.

Table II

Grade of perianchor cyst.

GradeASA (n = 58)PLLA (n = 44)P value
.158
046 (79)41 (93)
12 (3)2 (5)
24 (7)1 (2)
35 (9)0
41 (2)0

ASA, all-suture anchor; PLLA, poly-L-lactic acid.

Characteristics of study patients. WoC, without cyst; WC, with cyst; BMI, body mass index; MRI, magnetic resonance imaging. Grade of perianchor cyst. ASA, all-suture anchor; PLLA, poly-L-lactic acid. The WoC cohort had twelve shoulders, and the WC cohort had eleven shoulders. There was no significant difference between either mean time of surgery to postoperative MRI (WoC 111.5 weeks, SD 50.1; WC 121.3 weeks, SD 63.2; P = .786) or mean time of surgery to last follow-up (WoC 110.7 weeks, SD 40.8; WC 116.4 weeks, SD 53.2; P = .705). MRI was completed after the last follow-up for 19 of 23 patients and before the last follow-up in 4 of 23 patients (3 WoC, 1 WC). Regarding range of motion, no difference was found in mean FF (WoC 165.0, WC 153.6, P = .051), ER (WoC 41.7, WC 39.5, P = .336), and IR (P = .081). There was no statistically significant difference in supraspinatus strength (P = .317) and infraspinatus strength (P = .478) between WoC and WC cohorts. Range of motion and strength scores are described in Table III. ASES and UCLA scores were obtained for eleven shoulders in the WoC group and ten shoulders in the WC group. The WoC cohort had a significantly higher UCLA score (mean 34.3, 31-35) than the WC cohort (mean 30.9, 19-35), P = .024. The ASES score showed no statistically significant difference between the two cohorts (WoC 93.6, 86.6-100 vs. WC 78.8, 30-100; P = .073). The rotator cuff retear rate was 21.7% (5/23), with two occurring in WoC and three in WC (P = .640).
Table III

Clinical outcomes.

OutcomeWoC (n = 12)WC (n = 11)P value
FF (degrees)165 (160-180)153.6 (120-170).051
ER (degrees)41.7 (30-45)39.5 (30-45).336
IR (degrees).081
 Buttock03 (27)
 L12 (17)1 (9)
 L23 (25)0
 L31 (8)3 (27)
 L41 (8)3 (27)
 L51 (8)0
 T124 (33)1 (9)
Supraspinatus.317
 4/51 (8)3 (27)
 5/511 (92)8 (73)
Infraspinatus.478
 4/501 (9)
 5/512 (100)10 (91)
ASES93.6 (86.6-100)78.8 (30-100).073
UCLA34.3 (31-35)30.9 (19-35).024
Re-tear2 (17)3 (27).640

WoC, without cyst; WC, with cyst; FF, forward flexion; ER, external rotation; IR, internal rotation; ASES, American Shoulder and Elbow Surgeons; UCLA, University of California at Los Angeles.

P < .05, statistically significant P value.

Clinical outcomes. WoC, without cyst; WC, with cyst; FF, forward flexion; ER, external rotation; IR, internal rotation; ASES, American Shoulder and Elbow Surgeons; UCLA, University of California at Los Angeles. P < .05, statistically significant P value.

Discussion

This study investigated the bone reaction of ASA and PLLA anchors and the impact of PCF on functional outcomes. Several hypotheses have been proposed as to the etiology of PCF, including micromotion, foreign-body reaction, and synovitis. Initially used for labral repairs, ASAs have recently been gaining popularity in rotator cuff repairs because of the satisfactory results of both biomechanical and clinical trials., ASAs use a smaller implant with reports of equivalent strength and little bone reaction compared with traditional suture anchors. Van der Bracht et al showed 90% (43/48) of ASAs had no fluid collection at an average of 1.58 years after rotator cuff repair. This is slightly higher than the results obtained in the present study; however, they evaluated fewer anchors and had a shorter interval between surgery and MRI. It has been shown that osteolysis appears twelve weeks postoperatively for PLLA anchors and increases in size as time progresses. A recent study by Kim et al compared four different suture anchors (ASA, PEEK, and two different biodegradable anchors) between two groups (ASA + biodegradable 1 vs. PEEK + biodegradable 2) using a double-row rotator cuff repair. Their study showed a statistically significant higher rate of PCF around PEEK anchors (41.7%, 15/36) than ASAs (10.8%, 4/37), P < .05. When the ASA was compared to the biodegradable anchor used in the same patient, there was no statistical difference as seen in our study. It has been theorized the medial row undergoes higher forces than the lateral row during a double-row rotator cuff repair., This could result in different pressures on the bone-anchor interface, allowing for micromotion in the implant and ultimately changes in rate of PCF. An increased size of the anchor may lead to increased stability and less micromotion. Regarding the lateral row, it was initially thought there could be increased bone reaction secondary to softer bone and less coverage by tendinous tissue. However, Haneveld et al investigated this phenomenon and found the location of the anchor in the humeral head did not impact the amount of peri-implant fluid. Several studies have reported no statistically significant difference in clinical outcomes when comparing patients with and without PCF.,, Ro et al found no difference in visual analog scale scores, muscle strength, and range of motion between ASA, bioabsorbable, and PEEK anchors at a mean follow-up of 9.6 months. However, they did find an association between larger retear size and higher grade PCF. Most rotator cuff repair studies investigating PCF had shorter clinical follow-up times of around 1 to 1.5 years.,,, A study by Haneveld et al compared PLLA to PEEK anchors with a mean follow-up of 28.4 ± 8.9 months and found no clinical difference between the two groups. Pilge et al had a mean follow-up time of 36 months after mini-open rotator cuff repairs with only a single type of bioabsorbable anchor (Bio-Corkscrew suture anchor; Arthrex, Naples, FL) and found no clinical difference in range of motion or Constant-Murley shoulder outcome score. Our article reports similar follow-up times to the study by Haneveld et al with the benefit of having patients as their own internal control. With extended postoperative follow-up, there was still no difference in range of motion or rotator cuff strength between WoC and WC cohorts. In this study, our data demonstrated a significantly higher UCLA score in patients without PCF (34.3 vs. 30.9, P < .05). Additionally, range of motion and rotator cuff strength were measured by visual examination by the senior author. Prior studies report fair to good reliability with standard error measurements of 14-25 degrees for inter-rater and 11-23 degrees for intrarater., The standard error measurements in addition to the small population size could account for the trend seen toward greater FF scores in the WoC cohort (165° vs. 154°, P = .05). As FF score is a component of the UCLA survey (but not the ASES survey), this could be a contributing factor to the higher UCLA scores in the WoC cohort. It is important to note that the maximum score for FF on the UCLA survey is for >150°, and therefore, any range of motion greater than this may not have clinical significance. Hence, the difference in FF scores seen in our study may not be clinically relevant. Similar to other authors, none of the other range of motion outcomes (ER and IR) in this study were close to approaching a statistically significant difference. There has been increasing interest in PCF and its clinical implications, especially as increasingly more types of anchors are becoming available to surgeons. This article is in agreement with previous studies finding no difference in clinical outcomes if a cyst develops, even at a more extended follow-up period. Future studies investigating anchor biomechanics, pull-out strength, and ease of use would be valuable to assess whether these factors are important in differentiating between types of anchor and anchor selection for patients. There were several limitations to this study. First, the small sample size may have made the study underpowered. However, a post-hoc power analysis from a previous study on PCF prevalence revealed that a sample size of 41 anchors in each group achieves >80% power to detect a relative difference of 50% between the studied groups. Our study included n = 58 ASA and n = 44 PLLA anchors. All ASAs were placed on the medial row and PLLA anchors on the lateral row, so any force vectors were not standardized between the two anchor types. However, all patients underwent the same surgical treatment, and each patient served as their own control with medial and lateral anchor rows, thus reducing confounding factors. The number of anchors used in each row was not standardized. In some patients, the postoperative range of motion and strength scores were assessed after the MRI was performed, which could have influenced the assessment. There was also no protocol as to the timing of postoperative MRIs.

Conclusion

There was no significant difference in PCF incidence between ASAs and PLLA biocomposite anchors. At extended mean follow-up times of over two years, patients without PCF had significantly higher functional outcome scores. Range of motion and rotator cuff strength were equivalent between the two cohorts.

Disclaimers

Funding: This study was sponsored by , who provided funding for postoperative magnetic resonance imaging and research overhead. Conflicts of interest: Aruna Seneviratne received financial support by for research overhead. The other authors, their immediate families, and any research foundation with which they are affiliated did not receive any financial payments or other benefits from any commercial entity related to the subject of this article.
  27 in total

1.  Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study.

Authors:  Ignacio Carbonel; Angel Antonio Martinez; Angel Calvo; Jorge Ripalda; Antonio Herrera
Journal:  Int Orthop       Date:  2012-05-16       Impact factor: 3.075

2.  Prevalence of symptomatic and asymptomatic rotator cuff tears in the general population: From mass-screening in one village.

Authors:  Hiroshi Minagawa; Nobuyuki Yamamoto; Hidekazu Abe; Masashi Fukuda; Nobutoshi Seki; Kazuma Kikuchi; Hiroaki Kijima; Eiji Itoi
Journal:  J Orthop       Date:  2013-02-26

Review 3.  Single Vs Double row repair in rotator cuff tears - A review and analysis of current evidence.

Authors:  Al-Achraf Khoriati; Tony Antonios; Abhinav Gulihar; Bijayendra Singh
Journal:  J Clin Orthop Trauma       Date:  2019-01-30

4.  Pullout strength of all suture anchors in the repair of rotator cuff tears: a biomechanical study.

Authors:  Alexandre Galland; Stéphane Airaudi; Renaud Gravier; Sophie Le Cann; Patrick Chabrand; Jean-Noël Argenson
Journal:  Int Orthop       Date:  2013-07-09       Impact factor: 3.075

5.  Poly-L-lactic acid tack synovitis after arthroscopic stabilization of the shoulder.

Authors:  Michael Q Freehill; Dana J Harms; Shane M Huber; Dogan Atlihan; Daniel D Buss
Journal:  Am J Sports Med       Date:  2003 Sep-Oct       Impact factor: 6.202

6.  Changes in Perianchor Cyst Formation Over Time After Rotator Cuff Repair: Influential Factors and Outcomes.

Authors:  Seok Won Chung; Yong-Soo Lee; Ja-Yeon Kim; Jung-Ho Lee; Se-Young Ki; Kyung-Soo Oh; Jong Pil Yoon; Joon Yub Kim
Journal:  Am J Sports Med       Date:  2018-11-28       Impact factor: 6.202

7.  Medial rotator cuff failure after arthroscopic double-row rotator cuff repair.

Authors:  John N Trantalis; Richard S Boorman; Kristie Pletsch; Ian K Y Lo
Journal:  Arthroscopy       Date:  2008-06       Impact factor: 4.772

8.  Current biomechanical concepts for rotator cuff repair.

Authors:  Thay Q Lee
Journal:  Clin Orthop Surg       Date:  2013-05-15

Review 9.  Complications of rotator cuff surgery-the role of post-operative imaging in patient care.

Authors:  R S Thakkar; S C Thakkar; U Srikumaran; E G McFarland; L M Fayad
Journal:  Br J Radiol       Date:  2014-04-15       Impact factor: 3.039

10.  Serial MRI evaluation following arthroscopic rotator cuff repair in double-row technique.

Authors:  Katharina Stahnke; Constanze Nikulka; Gerd Diederichs; Hendrik Haneveld; Markus Scheibel; Christian Gerhardt
Journal:  Arch Orthop Trauma Surg       Date:  2016-02-02       Impact factor: 3.067

View more
  1 in total

1.  Rotator cuff repair with biodegradable high-purity magnesium suture anchor in sheep model.

Authors:  Yudie Chen; Yu Sun; Xinhui Wu; Jie Lou; Xiaonong Zhang; Zhaoxiang Peng
Journal:  J Orthop Translat       Date:  2022-09-10       Impact factor: 4.889

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.