Literature DB >> 18514118

Medial rotator cuff failure after arthroscopic double-row rotator cuff repair.

John N Trantalis1, Richard S Boorman, Kristie Pletsch, Ian K Y Lo.   

Abstract

Persistent tendon defects after rotator cuff repair are not uncommon. Recently, the senior author has identified a subset of 5 patients (mean age, 52 years; range, 42 to 59 years) after arthroscopic double-row rotator cuff repair who showed an unusual mechanism of tendon failure. In these patients the tendon footprint appears well fixed to the greater tuberosity with normal thickness. However, medial to the intact footprint, the tendon is torn with full-thickness defects through the rotator cuff. All patients were involved in Workers' Compensation claims. Magnetic resonance arthrography showed an intact cuff footprint but dye leakage in all patients. Revision surgery was performed at a mean of 8.6 months after the index procedure and showed an intact rotator cuff footprint but cuff failure medial to the footprint. Four patients had repair of the defects by tendon-to-tendon side-to-side sutures, whereas one did not undergo repair. Medial-row failure of the rotator cuff is a previously unreported mechanism of failure after double-row rotator cuff repair. Given the small number of patients in this study, it is unclear whether these defects are symptomatic. However, repair of these defects resulted in improvement in pain in 4 of 5 patients.

Entities:  

Mesh:

Year:  2008        PMID: 18514118     DOI: 10.1016/j.arthro.2008.03.009

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  44 in total

Review 1.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

2.  Arthroscopic transtendon suture-bridge technique for concurrent articular- and bursal-side partial-thickness rotator cuff tears.

Authors:  Kyung Cheon Kim; Kwang Jin Rhee; Hyun Dae Shin; Dong Kyu Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-06-16       Impact factor: 4.342

3.  Changes in tendon length with increasing rotator cuff tear size.

Authors:  Kyung Cheon Kim; Hyun Dae Shin; Bo Kun Kim; Soo Min Cha; Jun Yeong Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-17       Impact factor: 4.342

Review 4.  Advances in biology and mechanics of rotator cuff repair.

Authors:  Olaf Lorbach; Mike H Baums; Tanja Kostuj; Stephan Pauly; Markus Scheibel; Andrew Carr; Nasim Zargar; Maristella F Saccomanno; Giuseppe Milano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-09       Impact factor: 4.342

5.  Clinical outcomes and structural integrity of arthroscopic double-row versus suture-bridge repair for rotator cuff tears.

Authors:  Hiroshi Hashiguchi; Satoshi Iwashita; Kentaro Sonoki; Kazumasa Abe; Minoru Yoneda; Shinro Takai
Journal:  J Orthop       Date:  2018-03-17

Review 6.  Graft use in the treatment of large and massive rotator cuff tears: an overview of techniques and modes of failure with MRI correlation.

Authors:  Kyle R Duchman; Dayne T Mickelson; Barrett A Little; Thomas W Hash; Devin B Lemmex; Alison P Toth; Grant E Garrigues
Journal:  Skeletal Radiol       Date:  2018-07-05       Impact factor: 2.199

Review 7.  [Recurrent defects of the rotary cuff : Causes and therapeutic strategies].

Authors:  M Scheibel
Journal:  Oper Orthop Traumatol       Date:  2012-11       Impact factor: 1.154

8.  In vivo blood flow after rotator cuff reconstruction in a sheep model: comparison of single versus double row.

Authors:  Dennis Liem; Nicolas J Dedy; Gregor Hauschild; Georg Gosheger; Shirin Meier; Maurice Balke; Hans-Ulrich Spiegel; Bjoern Marquardt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-07       Impact factor: 4.342

9.  Arthroscopic double-row repair of the rotator cuff: a comparison of bio-absorbable and non-resorbable anchors regarding osseous reaction.

Authors:  Hendrik Haneveld; Konstantin Hug; Gerd Diederichs; Markus Scheibel; Christian Gerhardt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-21       Impact factor: 4.342

10.  Initial load-to-failure and failure analysis in single- and double-row repair techniques for rotator cuff repair.

Authors:  M H Baums; G H Buchhorn; F Gilbert; G Spahn; W Schultz; H-M Klinger
Journal:  Arch Orthop Trauma Surg       Date:  2010-01-05       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.