Literature DB >> 34483347

Anodic Stripping Voltammetry on a Carbon-based Ion-Selective Electrode.

Suji Park1, Claudia S Maier1, Dipankar Koley1.   

Abstract

In this study, we demonstrated the unique capability of carbon-based ion-selective electrode (ISE) to perform highly sensitive square wave anodic stripping voltammetry, while maintaining all the properties of an ISE, in terms of sensitivity, detection limit, response time and selectivity. Square wave anodic stripping voltammetry involves deposition and dissolution steps of metal ions, which means adsorption and desorption of metal ions on the conductive ion-selective membrane without losing its ion-sensing property. To demonstrate this capability, we chose a Ca2+ ion-selective microelectrode (μISE) as a potentiometric method and Cu2+-stripping voltammetry as an amperometric method. The carbon-based ISE surface is capable of quantifying nanomolar to micromolar Cu2+ in both a standard acetate buffer and a complex water sample. The Ca2+-μISE also showed a Nernstian slope of 29 mV / log [Ca2+] and a detection limit of 1 μM within the linear range of 1 μM to 10 mM. It thus opens an opportunity to use the low detection limit of anodic stripping voltammetry and the high selectivity of ISE-based potentiometry.

Entities:  

Year:  2021        PMID: 34483347      PMCID: PMC8415442          DOI: 10.1016/j.electacta.2021.138855

Source DB:  PubMed          Journal:  Electrochim Acta        ISSN: 0013-4686            Impact factor:   7.336


  17 in total

1.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics.

Authors:  Eric Bakker; Philippe Bühlmann; Ernö Pretsch
Journal:  Chem Rev       Date:  1997-12-18       Impact factor: 60.622

2.  Picomolar detection limits with current-polarized Pb2+ ion-selective membranes.

Authors:  E Pergel; R E Gyurcsányi; K Tóth; E Lindner
Journal:  Anal Chem       Date:  2001-09-01       Impact factor: 6.986

3.  Direct evidence of ionic fluxes across ion-selective membranes: a scanning electrochemical microscopic and potentiometric study.

Authors:  R E Gyurcsányi; E Pergel; R Nagy; I Kapui; B T Lan; K Tóth; I Bitter; E Lindner
Journal:  Anal Chem       Date:  2001-05-01       Impact factor: 6.986

4.  Pulstrodes: triple pulse control of potentiometric sensors.

Authors:  Sergey Makarychev-Mikhailov; Alexey Shvarev; Eric Bakker
Journal:  J Am Chem Soc       Date:  2004-09-01       Impact factor: 15.419

5.  Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact.

Authors:  Chun-Ze Lai; Melissa A Fierke; Andreas Stein; Philippe Bühlmann
Journal:  Anal Chem       Date:  2007-05-18       Impact factor: 6.986

6.  Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers.

Authors:  Gastón A Crespo; Santiago Macho; F Xavier Rius
Journal:  Anal Chem       Date:  2008-02-15       Impact factor: 6.986

7.  Construction of a carbon ionic liquid paste electrode based on multi-walled carbon nanotubes-synthesized Schiff base composite for trace electrochemical detection of cadmium.

Authors:  Abbas Afkhami; Hosein Khoshsafar; Hasan Bagheri; Tayyebeh Madrakian
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2013-10-31       Impact factor: 7.328

8.  Real-time monitoring of calcification process by Sporosarcina pasteurii biofilm.

Authors:  Dustin Harris; Jyothir Ganesh Ummadi; Andrew R Thurber; Yvan Allau; Circe Verba; Frederick Colwell; Marta E Torres; Dipankar Koley
Journal:  Analyst       Date:  2016-05-10       Impact factor: 4.616

9.  Anodic stripping voltammetry with carbon paste electrodes for rapid Ag(I) and Cu(II) determinations.

Authors:  C Labar; L Lamberts
Journal:  Talanta       Date:  1997-05       Impact factor: 6.057

10.  Obtaining Nernstian response of a Ca(2+)-selective electrode in a broad concentration range by tuned galvanostatic polarization.

Authors:  Maria A Peshkova; Tomasz Sokalski; Konstantin N Mikhelson; Andrzej Lewenstam
Journal:  Anal Chem       Date:  2008-12-01       Impact factor: 6.986

View more
  4 in total

1.  Calibration-free Solid-State Ion-Selective Electrode Based on a Polarized PEDOT/PEDOT-S-Doped Copolymer as Back Contact.

Authors:  Christopher Bahro; Subir Goswami; Sarah Gernhart; Dipankar Koley
Journal:  Anal Chem       Date:  2022-06-03       Impact factor: 8.008

2.  Real-time monitoring of the pH microenvironment at the interface of multispecies biofilm and dental composites.

Authors:  Anh Tuan Nguyen; Subir Goswami; Jack Ferracane; Dipankar Koley
Journal:  Anal Chim Acta       Date:  2022-02-14       Impact factor: 6.911

3.  Detection Efficiency of Ag Nanoparticle Labels for a Heart Failure Marker Using Linear and Square-Wave Anodic Stripping Voltammetry.

Authors:  Nikhil Raj; Richard M Crooks
Journal:  Biosensors (Basel)       Date:  2022-03-29

Review 4.  Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection.

Authors:  Jiawei Zhai; Bin Luo; Aixue Li; Hongtu Dong; Xiaotong Jin; Xiaodong Wang
Journal:  Sensors (Basel)       Date:  2022-07-25       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.