Priority of PET-CT vs CT Thorax for EBUS-TBNA 22G vs 19G: Mesothorax Lymphadenopathy.

Paul Zarogoulidis1,2, Haidong Huang3, Zhenli Hu3, Ning Wu3, Jiannan Wang3, Dimitris Petridis4, Kosmas Tsakiridis5, Dimitris Matthaios6, Christoforos Kosmidis2, Wolfgang Hohenforst-Schmidt7, Christos Tolis8, Ioannis Boukovinas9, Nikolaos Courcoutsakis10, George Nikolaidis11, Chrysanthi Sardeli12, Chong Bai3, Chrysanthi Karapantzou13.   

Abstract

Introduction: Lung lesions and undiagnosed mesothorax lymphadenopathy is an issue that several doctors face in the everyday clinical practice. PET-CT and CT of the thorax are usually the first examinations to identify characteristics of the lesions before biopsy. Patients and
Methods: We performed a retrospective study with 450 patients that had EBUS-TBNA with 22G, Upgraded 22G and 19G needles with and without PET-CT in order to identify the cost effeteness of performing EBUS-TBNA before or after PET-CT. All centers used the same PET-CT equipment and EBUS-TBNA system. Three types of needle were used for the endoscopy in order to identify similarities and differences for the cost-effectiveness. The costs in every center for every examination and materials were the same.
Results: There were more block slices for 19G>22Gupgraded>21G>22G and there was cost-effectiveness when in general PET-CT was performed prior to biopsy of any lesion. 19G needle was more effective for lymphomas, while 22Gupgraded and 21G needles were more cost-effective when used for smaller lesions for primary lung cancer of metastatic disease. Conclusions: We have been using PET-CT and EBUS-TBNA in the everyday clinical practice according to the current guidelines for initial disease staging and re-staging. However; we can also use both in a cost effective method based on the initial radiologic findings. © The author(s).

Entities:  

Keywords:  19G needle; 22G needle; CT; EBUS-TBNA; Mesothorax; PET-CT; lung cancer; lymphoma

Year:  2021        PMID: 34476000      PMCID: PMC8408124          DOI: 10.7150/jca.59892

Source DB:  PubMed          Journal:  J Cancer        ISSN: 1837-9664            Impact factor:   4.207


Introduction

Several patients are admitted to hospitals with different symptoms and radiology exams often reveal lesions in the thorax. Computed tomography (CT) of the thorax with or without intravenous contrast can be easily used in every tertiary hospital. Positron emission tomography (PET-CT) has been added in our diagnostic algorithm the last 12 years. It has been evaluated for several diseases both for benign and malignant diseases. It can be used either for initial diagnosis or initial staging, but also for the restaging of non-small cell lung cancer (NSCLC) disease 1-5. PET-CT has a substantial diagnostic value for single nodules of ≥0.8 mm. Several centers take a delayed second examination 20-30 minutes after the initial examination in order to identify malignancies with low metabolic rate. However; there are still issues where malignancies cannot be identified to the low metabolic rate 6. There is also still an issue with benign disease such as; sarcoidosis where PET-CT is under evaluation as a diagnostic tool 7. Endobronchial ultrasound (convex) is an endoscopic tool again with more than 10 years in service with 22G, 21G and 19G needles for biopsy. It is an excellent tool for initial diagnosis and staging in different diseases 8-10. The sample size is enough to perform gene investigation for several cancer types 11, 12. The role of PET-CT and EBUS-TBNA has been for several malignancies and an algorithm has been set. However; we do not have an algorithm to follow for undiagnosed mesothorax lymphadenopathy. Should we first perform PET-CT or we can proceed directly to biopsy. There is the issue of cost-effect regarding the needle that we have to use and the unnecessary PET-CT examinations which have a high cost. We performed a retrospective study to identify an algorithm through several institutions following the same diagnostic protocol and examination costs.

Patients and Methods

We enrolled 450 patients from our oncology and pulmonary outpatient cabinets. These patients came to our cabinets either with a CT of the thorax performed with intravenous contrast or PET-CT. The investigational review board (IRB) of the 3rd University General Hospital, “AHEPA” University Hospital, Thessaloniki, Greece provided us with the authorization of our study. A CT of the thorax with contrast costs 160 euros and a PET-CT 1150 euros. All patients had mesothorax lymphadenopathy. Endobronchial ultrasound (convex probe) was performed with a PENTAX EB-1970UK, EPK-1000 video processor and a Hitachi EUB-7500HV ultrasound source. The following needles were used; a) 22G Mediglobe®, b) 22G upgraded Mediglobe®, c) 21G Olympus® and d) 19G Olympus®. The costs for the needles were as follows: a) 170 euros, b) 330 euros, c) 440 euros and d) 520 euros. The EBUS procedure without the needles had a cost of 1300euros in every department including anesthesiology drugs, medical staff (nurse, anesthesiologist and doctor), pathology result and all other materials necessary for the examination. There was an extra cost of 350 euros for next generation sequencing (NGS) when this was necessary, but this was not information included in our study. Patients that had before the EBUS a PET-CT their examination had a total cost as follows for each needle: a) 259.475 euros, b) 280.780 euros, c) 289.000 euros and d) 112860 euros. All 344 patients that had an initial PET-CT before EBUS had a diagnosis and no false negative result. The rest of the 106 patients had only a CT of the thorax with intravenous contrast and the cost of the examination was as follows for each needle: a) 63.570 euros, b) 41.170 euros, c) 64.600 euros and d) 15.840 euros. All 106 patients did not have a diagnosis, and PET-CT was performed and then re-biopsy with EBUS-TBNA with the same needles in different puncture point where the PET-CT was highly positive with an SUV ≥3. The cost for the new examination of these patients after the PET-CT was as follows: a) 108.420 euros, b) 67.620 euros, c) 103.700 euros and d) 25.040 euros. The time between the new re-biopsy was 15 days for each patient. The money loss in total for the 106 patients was 304.780 euros. The total cost of the 344 patients was 942.115 euros (Table ).

Statistics

Methods

The efficiency of the positron emission tomography (PET) was investigated on patients with different cancer types using different needle sizes and dissecting various slices. The number of slices as affected by the needle size was detected using the 95% confidence interval plot of means based on ANOVA's error mean square. Also, the association among needle size, lesion size and cancer type was investigated employing a multiple correspondence analysis. The efficiency of the Modified electric convulsive treatment (MECT meaning patients that had PET-CT before the EBUS biopsy), was detected by plotting the slices mean against the lesion size and cancer type as similarly described above.

Results

For the PET apparatus Figure shows that the mean number of slices is twice much higher when needle 19 is used than those affiliated with the needles (22U) 22G upgraded Mediglobe® and 21G (equally performing) and the latter are again twice much higher than the mean slices associated with needle 22G (170 euros needle Mediglobe®). The multiple correspondence analysis pointed out an 85.25% explanation of inertia variation (Figure ) concerning the first two dimensions. Dimension 1 is best described by needle type 4 (19G Olympus® and cancer type 4 (Hodgkin) (see the partial contributions of coordinates in Figure ), both arranged at the right part of corresponding plot and far apart from the rest categories. Similarly, dimension 2 was best formed by lesion size 1 (≥1 cm) and cancer type 3 (higher contribution of the coordinates-Non-Hodgkin), both positioned at the lower part of the plot and also far apart from the other categories. Cancer type 2 (metastatic from other organs than the thorax) and lesion size 2 (≥2 cm) are also affiliated each other due to their close distance and moderate contributions for the axes formation. For the MECT (MECT meaning patients that had PET-CT before the EBUS biopsy) apparatus, the 95% confidence interval plot of slice means (Figure ) indicate that needles size 4 (19G Olympus®) produce the highest number of slices, those of size 2 (22G upgraded Mediglobe®) and 3 (21G Olympus®) intermediate ones and those of size 1 (≥1 cm) the lowest values (absent for lesion 4 ≥4 cm). Lesions show a similar pattern of slices in the needles across all lesion categories. The value of slices, needle type and cancer type in fact present a proportional cost-effectiveness due to the following reasons: The higher the number of slices, the larger the needle, the higher the cost; The cancer type Hodgkin, non-Hodgkin vs the other cancer types, increases the operation cost; Concerning the lesion size no cost-effective is reasonably expected thus, no real statistical information is possible to support an apparent effect as explained by the pre-explained reasons.

Discussion

Several studies have compared the cost-effectiveness and safety of EBUS-TBNA for diagnosis versus mediastinoscopy 13, 14. Certainly according to current guidelines for lung cancer PET-CT and EBUS-TBNA have an algorithm before mediastiscopy is performed 15. However; several patients refer to internal medicine doctors and general practitioners and not always to oncologists and pulmonary physicians. Currently there are no guidelines for undiagnosed lymphadenopathy of mesothorax. All our patients had malignancy because an initial work-up with medical history and because of the expertise of our departments patients referred to us were most likely to have malignancy. In other centers a part of these patients would include benign disease such post infection lymphadenopathy or sarcoidosis. We observed in our study again as it has been previously identified that 19G needle has larger biopsy sample almost double the size of a 22G needle 8, 16. The biopsy sample size was as follows in our study; d>c=b>a based on the needles. This observation was made with the number of cell block slices that were produced from each biopsy. The sample size did not differ among the different lesion size, this is due to the ebus technique where we have real time visualization of the lesion and several punctures can be made with safety indifferent of the needle. Needle size 19G we know from previous studies that is efficient for lymphomas 17. Cost-effectiveness is an issue for every health system and this is decided for each patient upon admission. A PET-CT is necessary to identify necrosis and the intensity of the lesions. Also, we can identify the part of the lesion which has the highest intensity in order to puncture this specific site (Figure ). We can observe in Figure that although someone could puncture lymphnode number 11L in this patient, no result would be available because there is no SUV uptake. This information would not available with a CT of the thorax even with i.v contrast. Several studies have been performed where elastography was used to identify the strain ratio of the lesions, however; without efficient results 18-20. Moreover; the use of the needle is another important cost, if we have the same number of block slices with less expenses then it would be preferred. However; health systems work different between Europe, China and the United States, and certainly PET-CT or EBUS-TBNA is not available in every hospital. The most important cost-effective decision is finally made by the initial physician and it would be preferred that these patients should be directed to centers of expertise with malignancies. A cost-effectiveness algorithm should be proposed by the scientific societies for the diagnostic work, not only for oncologists and pulmonary physicians, but also for other specialties (Figure ).
Table 1

Cost-Effectiveness of biopsies

NEEDLE22G MEDIGLOBE®22G UPGRADED MEDIGLOBE®21G OLYMPUS®19G OLYMPUS®
COST IN EUROS PER UNIT170330440520
344 PATIENTS WITH PET-CT259.475280.780289.000112.860
106 PATIENTS WITH CT THORAX63.57041.17064.60015.840
106 WITH RE-BIOPSY AFTER PET-CT108.42067.620103.70025.040
  20 in total

1.  Evaluating the use of elastography in endobronchial ultrasound technique as a diagnostic approach for mesothorax lymphadenopathy.

Authors:  Paul Zarogoulidis; Konstantinos Sapalidis; Varvara Fyntanidou; Christoforos Kosmidis; Aikaterini Amaniti; Charilaos Koulouris; Dimitrios Giannakidis; Kosmas Tsakiridis; Zoi Aidoni; Konstantinos Romanidis; Panagoula Oikonomou; Haidong Huang; Lutz Freitag; Wolfgang Hohenforst-Schmidt
Journal:  Expert Rev Respir Med       Date:  2019-10-17       Impact factor: 3.772

2.  Safety and Costs of Endobronchial Ultrasound-Guided Nodal Aspiration and Mediastinoscopy.

Authors:  Francys C Verdial; Kathleen S Berfield; Douglas E Wood; Michael S Mulligan; Joshua A Roth; David O Francis; Farhood Farjah
Journal:  Chest       Date:  2019-10-09       Impact factor: 9.410

3.  Incremental Value of FDG PET/CT in Aggressive High Grade B Cell lymphoma with TdT Expression.

Authors:  Nikita Sampathirao; Indirani Muthukrishnan; Ann Kurian; Jaykanth Amalchandran; Asra Patel; Shema Mathew; Shelley Simon
Journal:  Asia Ocean J Nucl Med Biol       Date:  2021

4.  Diagnostic performance of 19-gauge endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in suspected lymphoma: a prospective cohort study.

Authors:  Christopher E Lim; Daniel P Steinfort; Louis B Irving
Journal:  Clin Respir J       Date:  2020-04-19       Impact factor: 2.570

5.  Lung cancer research and its citation on clinical practice guidelines.

Authors:  Elena Pallari; Magnus Eriksson; Annika Billhult; Tommy Billhult; Ajay Aggarwal; Grant Lewison; Richard Sullivan
Journal:  Lung Cancer       Date:  2021-02-05       Impact factor: 5.705

6.  A Randomized Clinical Trial of Flex 19G Needles versus 22G Needles for Endobronchial Ultrasonography in Suspected Lung Cancer.

Authors:  Christophe Dooms; Sara Vander Borght; Jonas Yserbyt; Dries Testelmans; Els Wauters; Kristiaan Nackaerts; Johan Vansteenkiste; Eric Verbeken; Birgit Weynand
Journal:  Respiration       Date:  2018-06-29       Impact factor: 3.580

Review 7.  Spectrum of [18F]FDG-PET/CT Findings in Benign Lymph Node Pathology.

Authors:  Merissa N Zeman; Clare Green; Esma A Akin
Journal:  Mol Imaging Biol       Date:  2021-01-29       Impact factor: 3.488

8.  Efficient utilization of EBUS-TBNA samples for both diagnosis and molecular analyses.

Authors:  F Oezkan; Am Khan; P Zarogoulidis; W Hohenforst-Schmidt; D Theegarten; K Yasufuku; T Nakajima; L Freitag; K Darwiche
Journal:  Onco Targets Ther       Date:  2014-11-10       Impact factor: 4.147

9.  Genetic alterations associated with 18F-fluorodeoxyglucose positron emission tomography/computed tomography in head and neck squamous cell carcinoma.

Authors:  Sangwon Han; Jungsu S Oh; Hyo Sang Lee; Jae Seung Kim
Journal:  Transl Oncol       Date:  2020-12-20       Impact factor: 4.243

View more
  2 in total

1.  Cryo-Biopsy versus 19G needle versus 22G needle with EBUS-TBNA endoscopy.

Authors:  Rena Oikonomidou; Dimitris Petridis; Christoforos Kosmidis; Konstantinos Sapalidis; Wolfgang Hohenforst-Schmidt; Vagelis Christakidis; Savas Petanidis; Dimitris Mathaios; Eleni Isidora Perdikouri; Sofia Baka; Christos Tolis; Anastasios Vagionas; Bojan Zaric; Aris Ioannidis; Marios Anemoulis; Konstantinos Porpodis; Vasileios Papadopoulos; Paul Zarogoulidis
Journal:  J Cancer       Date:  2022-08-08       Impact factor: 4.478

2.  Cryobiopsy for pneumonitis diagnosis in NSCLC immunotherapy.

Authors:  Paul Zarogoulidis; Christoforos Kosmidis; Eleni-Isidora Perdikouri; Wolfgang Hohemforst-Schmidt; Chrisanthi Sardeli
Journal:  Respir Med Case Rep       Date:  2022-09-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.