Literature DB >> 34473002

Early institutional experience using the TracStar Large Distal Platform in endovascular flow diversion.

Devin V Bageac1, Blake S Gershon1, Tomoyoshi Shigematsu1, Shahram Majidi1, Reade A De Leacy1.   

Abstract

INTRODUCTION: The delivery of flow-diverting stents (FDS) necessitates a degree of catheter support beyond that required for endovascular coiling. The TracStar Large Distal Platform (LDP) is a novel 0.088″ platform intended for navigation into the intracranial internal carotid artery (ICA). We present an early institutional experience using the TracStar LDP in 44 cases of endovascular aneurysm embolization using FDS.
METHODS: Inclusion criteria for this single-center retrospective review encompassed all patients >18 years of age who were treated for intracranial aneurysms. Procedural success was defined as successful stent deployment using the TracStar LDP. Other outcomes included periprocedural complications, use of an intermediate catheter, length of stay, and discharge disposition.
RESULTS: The TracStar LDP was utilized in 44 consecutive FDS cases in 42 patients. Cavernous segment aneurysms constituted the majority of cases (12/42; 28.6%), followed by posterior communicating artery (8/42; 19.0%) and supraclinoid aneurysms (8/42; 19.0%). Successful FDS deployment was achieved in 43/44 cases. The LDP achieved stable positioning within the ascending cavernous ICA in 63.6% of cases. A biaxial system was utilized in 54.5% of cases. There was one complication potentially related to use of the TracStar LDP, which was an asymptomatic ICA vessel dissection managed conservatively.
CONCLUSIONS: The TracStar LDP is safe and effective during use in the endovascular treatment of intracranial aneurysms with a FDS. Access to the ascending portion of the cavernous ICA was regularly achieved, and the platform allowed for both biaxial and triaxial configurations.

Entities:  

Keywords:  Aneurysm; biaxial; device; flow diversion; guide catheter

Mesh:

Year:  2021        PMID: 34473002      PMCID: PMC9244741          DOI: 10.1177/19714009211041520

Source DB:  PubMed          Journal:  Neuroradiol J        ISSN: 1971-4009


  15 in total

1.  A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents.

Authors:  C J O'kelly; T Krings; D Fiorella; T R Marotta
Journal:  Interv Neuroradiol       Date:  2010-07-19       Impact factor: 1.610

Review 2.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

3.  Utilization of a Novel, Multi-Durometer Intracranial Distal Access Catheter: Nuances and Experience in 110 Consecutive Cases of Aneurysm Flow Diversion.

Authors:  Geoffrey P Colby; Li-Mei Lin; Risheng Xu; Narlin Beaty; Matthew T Bender; Bowen Jiang; Judy Huang; Rafael J Tamargo; Alexander L Coon
Journal:  Interv Neurol       Date:  2017-02-03

4.  Biaxial system using the Benchmark intracranial guide catheter for placement of a Pipeline Embolization Device for intracranial aneurysms.

Authors:  Apar S Patel; Christoph J Griessenauer; Christopher S Ogilvy; Ajith J Thomas
Journal:  Interv Neuroradiol       Date:  2016-02-22       Impact factor: 1.610

5.  Flow-diversion for ophthalmic segment aneurysms.

Authors:  Mario Zanaty; Nohra Chalouhi; Guilherme Barros; Eric Winthrop Schwartz; Mark Philip Saigh; Robert M Starke; Alex Whiting; Stavropoula I Tjoumakaris; David Hasan; Robert H Rosenwasser; Pascal Jabbour
Journal:  Neurosurgery       Date:  2015-03       Impact factor: 4.654

6.  Immediate procedural outcomes in 44 consecutive Pipeline Flex cases: the first North American single-center series.

Authors:  Geoffrey P Colby; Li-Mei Lin; Justin M Caplan; Bowen Jiang; Judy Huang; Rafael J Tamargo; Alexander L Coon
Journal:  J Neurointerv Surg       Date:  2015-07-01       Impact factor: 5.836

7.  Endovascular treatment of intracranial 'blister' and dissecting aneurysms.

Authors:  Marius G Kaschner; Bastian Kraus; Athanasios Petridis; Bernd Turowski
Journal:  Neuroradiol J       Date:  2019-07-04

8.  Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization device.

Authors:  Geoffrey P Colby; Li-Mei Lin; Judy Huang; Rafael J Tamargo; Alexander L Coon
Journal:  J Neurointerv Surg       Date:  2013-03-20       Impact factor: 5.836

9.  First clinical report of aspiration through a novel 0.088-inch catheter positioned in the M1 middle cerebral artery for ELVO thrombectomy.

Authors:  Blake S Gershon; Devin V Bageac; Tomoyoshi Shigematsu; Shahram Majidi; Reade De Leacy
Journal:  BMJ Case Rep       Date:  2020-10-08

10.  47 Consecutive Cases of Pipeline Flex Flow Diversion Utilizing a Novel Large-Bore Intracranial Intermediate Catheter: Nuances and Institutional Experience with the Syphontrak.

Authors:  Li-Mei Lin; Bowen Jiang; Matthew T Bender; Erick M Westbroek; Jessica K Campos; Rafael J Tamargo; Judy Huang; Alexander L Coon; Geoffrey P Colby
Journal:  Interv Neurol       Date:  2018-02-06