Literature DB >> 34471478

Preparation and In Vitro Analysis of Craniofacial Titanium Implants Surfaces Produced by Additive 3D Printing and Conventional Manufacturing.

Muhanad M Hatamleh1,2.   

Abstract

STUDY
DESIGN: Surface finish of titanium patient-specific craniofacial implants is known to affect their acceptability and durability and relevant literature still inconclusive on the best surface finishing protocol.
OBJECTIVES: This study investigated surface topography of three-dimensionally (3D) printed and conventionally manufactured craniofacial titanium implants following non-contact 3D laser profile-meter analysis.
METHODS: Seven groups of titanium specimens (n = 10) were prepared and their surfaces were treated differently and included sole or combined treatment of mechanical polishing, gritting with 50 micron AL2O3, cold acid treatment using nitric acid for 20 hours (70% w/w), etching using acidic solution (69% nitric and 48% hydrofluoric acids) for 10 minutes and then electro-chemically anodized in another acidic solution (85% orthophosphoric and 98%sulphuric acid). Eighth group included specimens that were 3D printed. 3D micro-roughness parameters Sa, Sp, Sv, and Sz were determined (μm) for each specimen. Data was analyzed using one way ANOVA and Dunett T3 post-hoc tests (p < 0.05).
RESULTS: There were statistically significant effects of surface finishing protocols (p < 0.05). Sa values were 2.72-13.75 and specimens which were electroplated or mechanically polished and acid treated were the smoothest (p < 0.05). Sp was in the range 9.07-43.56 as sandblasting significantly roughened surfaces (p < 0.05). The same inferior effect was evident for the Sv (p < 0.05). The Sz values were 19.46-107.05 and was the highest for sandblasted surfaces (p < 0.05) and the lowest for surfaces of electro-chemical treatment (p < 0.05).
CONCLUSION: Titanium surfaces are affected by the finishing procedure and electro-chemical treatment or mechanical polishing combined with acid treatment produced clinically-favorable smooth surfaces.
© The Author(s) 2020.

Entities:  

Keywords:  cranioplasty; skull reconstruction; surface topography; titanium implant

Year:  2020        PMID: 34471478      PMCID: PMC8385633          DOI: 10.1177/1943387520970792

Source DB:  PubMed          Journal:  Craniomaxillofac Trauma Reconstr        ISSN: 1943-3875


  27 in total

1.  Effect of different Ti-6Al-4V surface treatments on osteoblasts behaviour.

Authors:  Ching-Hsin Ku; Dominique P Pioletti; Martin Browne; Peter J Gregson
Journal:  Biomaterials       Date:  2002-03       Impact factor: 12.479

Review 2.  Surface treatments of titanium dental implants for rapid osseointegration.

Authors:  L Le Guéhennec; A Soueidan; P Layrolle; Y Amouriq
Journal:  Dent Mater       Date:  2006-08-14       Impact factor: 5.304

Review 3.  Metallic biomaterials.

Authors:  Mitsuo Niinomi
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

4.  Mandibular reconstruction using computer-aided design and computer-aided manufacturing: an analysis of surgical results.

Authors:  Benjamin D Foley; Wesly P Thayer; Adam Honeybrook; Samuel McKenna; Steven Press
Journal:  J Oral Maxillofac Surg       Date:  2012-11-17       Impact factor: 1.895

5.  Effect of titanium surface roughness on human osteoblast proliferation and gene expression in vitro.

Authors:  Lorella Marinucci; Stefania Balloni; Ennio Becchetti; Salvatore Belcastro; Mario Guerra; Mario Calvitti; Cinzia Lilli; Edoardo Maria Calvi; Paola Locci
Journal:  Int J Oral Maxillofac Implants       Date:  2006 Sep-Oct       Impact factor: 2.804

6.  Surface characteristics and biocompatibility of cranioplasty titanium implants following different surface treatments.

Authors:  Muhanad M Hatamleh; Xiaohong Wu; Ahmad Alnazzawi; Jason Watson; David Watts
Journal:  Dent Mater       Date:  2018-04       Impact factor: 5.304

7.  Correction of facial and mandibular asymmetry using a computer aided design/computer aided manufacturing prefabricated titanium implant.

Authors:  Jason Watson; Muhanad Hatamleh; Ahed Alwahadni; Dilip Srinivasan
Journal:  J Craniofac Surg       Date:  2014-05       Impact factor: 1.046

8.  Primary and secondary reconstruction of complex craniofacial defects using polyetheretherketone custom-made implants.

Authors:  Giovanni Gerbino; Emanuele Zavattero; Francesco Zenga; Francesca Antonella Bianchi; Paolo Garzino-Demo; Sid Berrone
Journal:  J Craniomaxillofac Surg       Date:  2015-07-08       Impact factor: 2.078

9.  Effect of cpTi surface roughness on human bone marrow cell attachment, proliferation, and differentiation.

Authors:  Adalberto Luiz Rosa; Márcio Mateus Beloti
Journal:  Braz Dent J       Date:  2003-07-31

Review 10.  3D modeling, custom implants and its future perspectives in craniofacial surgery.

Authors:  Jayanthi Parthasarathy
Journal:  Ann Maxillofac Surg       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.