Investigation of the parallel conductor model of impedance cardiography by means of exchange transfusion with stroma free haemoglobin solution in the dog.

K R Visser1, R Lamberts, W G Zijlstra.   

Abstract

To test one of the assumptions underlying the calculation of stroke volume--namely, that the transthoracic impedance consists of a parallel connection of a tissue impedance and a blood resistance--experiments were carried out on four dogs in which blood was gradually replaced by a stroma free haemoglobin solution, with the purpose of changing the blood resistance while leaving the tissue impedance unchanged. This was accomplished by exchange transfusion in such a way that the volume of the circulating fluid remained constant and the distribution of fluid volume between the fluid compartments was not altered. During the exchange transfusions the mean decrease in resistivity of the circulating fluid was 54%. The packed cell volume and resistivity of every volume of removed circulating fluid were measured. Just before each exchange the real and imaginary parts of the transthoracic impedance were measured. The packed cell volume decreased exponentially with the number of exchanges. This indicates that the circulating fluid volume remained constant during the exchange transfusion. From the packed cell volumes an estimate of the circulating fluid volume was made. Because of the parallel connection all calculations were based on the use of admittance, which is the reciprocal value of impedance. The real and imaginary parts of the transthoracic admittance were calculated from the measured values of the real and imaginary parts of the transthoracic impedance.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3446367     DOI: 10.1093/cvr/21.9.637

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  6 in total

1.  The electrical impedance of plasma: a laboratory simulation of the effect of changes in chemistry.

Authors:  H D Fuller
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

2.  The effect of haematocrit on transthoracic electrical impedance and on the calculation of cardiac output by an impedance cardiograph.

Authors:  A Thomas; A Vohra; B Pollard
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

3.  Stroke volume equation for impedance cardiography.

Authors:  D P Bernstein; H J M Lemmens
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

4.  The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients.

Authors:  H H Woltjer; H J Bogaard; H I van der Spoel; P M de Vries
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

5.  Voltage clamp method for the use of electrical admittance plethysmography in human body segments.

Authors:  K Yamakoshi; M Nakagawara
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

6.  Feasibility, reproducibility and accuracy of electrical velocimetry for cardiac output assessment in congenital heart disease.

Authors:  Alexander C Egbe; Muhammad Wajih Ullah; Arslan Afzal; Keerthana Banala; Rahul Vojjini; Maria Najam; Karim Osman; Sahith Thotamgari; Donald J Hagler
Journal:  Int J Cardiol Heart Vasc       Date:  2020-01-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.