Literature DB >> 34447603

A Synoptic Reporting System to Monitor Bone Marrow Aspirate and Biopsy Quality.

Roger S Riley1, Paras Gandhi2, Susan E Harley3, Paulo Garcia4, Justin B Dalton1, Alden Chesney1.   

Abstract

OBJECTIVES: Bone marrow evaluation plays a critical role in the diagnosis, staging, and monitoring of many diseases. Although there are standardized guidelines for assessing bone marrow specimen quality, there is a lack of evidence-based tools to perform such assessments. The objective was to monitor bone marrow sample quality in real time by standardizing the basic components of a synoptic report and incorporating it into a bone marrow report template.
MATERIALS AND METHODS: A relational database of bone marrow quality parameters was developed and incorporated into our laboratory information system bone marrow report template, with data entry completed during specimen sign out. Data from multiple reports created within a date range were extracted by Structured Query Language query, and summarized in tabular form. Reports generated from these data were utilized in quality improvement efforts.
RESULTS: The synoptic reporting system was routinely used to record the quality of bone marrow specimens from adult patients. Data from 3189 bone marrow aspirates, 3302 biopsies, and 3183 biopsy touch imprints identified hemodilution as the principal issue affecting bone marrow aspirate quality, whereas aspiration artifact and fragmentation affected bone marrow biopsy quality.
CONCLUSIONS: The bone marrow synoptic reporting process was easy to use, readily adaptable, and has proved a useful component of the overall quality assurance process to optimize bone marrow quality. Copyright:
© 2021 Journal of Pathology Informatics.

Entities:  

Keywords:  Bone marrow specimen quality; laboratory information management system; pathology informatics; synoptic reporting

Year:  2021        PMID: 34447603      PMCID: PMC8356705          DOI: 10.4103/jpi.jpi_53_20

Source DB:  PubMed          Journal:  J Pathol Inform


INTRODUCTION

Bone marrow evaluation plays a critical role in the diagnosis, staging, and monitoring of many diseases involving the hematolymphoid system. The bone marrow procedure involves the aspiration of liquid marrow and acquisition of a core of bone marrow tissue using special needles. The specimens are usually obtained from the posterior iliac crest, with the anterior iliac crest and sternum providing alternate collection sites. Aspirates are used for the preparation of Wright-Giemsa-stained smears and special studies, such as flow cytometry, while the core biopsy is fixed in formalin, embedded in paraffin, sectioned, and stained with H and E and other stains. However, accurate morphologic interpretation and reliable information from special studies are possible only if enough bone marrow cells and an adequate biopsy core specimen are collected during the procedure. Inadequate bone marrow specimens may delay or compromise patient care or require expensive and painful repeat procedures. For these reasons, bone marrow specimen quality is a major concern to hematopathologists. Detailed guidelines for standardization of the procurement, processing, interpretation, and reporting of bone marrow specimens have been published by the International Society for Laboratory Hematology (ISLH), the College of American Pathologists (CAP), and other expert groups.[1234] These guidelines define adequate bone marrow smears as containing multiple particles with “trails” of well-stained, morphologically well-defined bone marrow cells. Inadequate aspirate specimens are often the result of hemodilution, excessive thickness, poor staining, or crushed, unrecognizable cells from excessive pressure during smear preparation. The bone marrow core biopsy should be of adequate length, intact, well-fixed, uniformly sectioned, and well-stained. Common problems affecting bone marrow core biopsies include: Inadequate length (subcortical specimens), aspiration artifact, fragmentation, and poor fixation, sectioning, or staining.[5] Operator technique and experience, needle type, and the use of a specimen preparation checklist have been identified as factors that affect bone marrow specimen quality.[367] A summary of the causes of suboptimal bone marrow specimen quality is presented in Table 1.
Table 1

Factors that compromise bone marrow specimen quality

SpecimenArtifactCause
Bone marrow aspirationSuboptimal stainingOld or contaminated staining solution, inadequate staining time
Inadequate particlesPoor aspiration technique, “dry tap”
Cell crushing and distortionInadequate training, improper procedure
Thick smearsClotted specimen, inadequate training, improper procedure
Uneven cell distributionClotted specimen, inadequate training, improper procedure
Clotted specimenPoor technique, multiple aspiration attempts with local activation of coagulation system, hyperactive coagulation system
Bone marrow biopsyAspiration artifactBiopsy of aspiration site, failure to obtain aspirate and biopsy specimens from different areas
Suboptimal stainingInadequate fixation of processing, expired or contaminated staining solution
Biopsy of previous aspiration or biopsy siteFailure to reorient biopsy needle at a proper angle or to a proper site
Crushed or fragmented specimenHarsh handling during touch imprint preparation or processing, inadequate microtomy
Inadequate fixationInadequate volume of fixative solution, inadequate fixation time
Excessive decalcificationPoor tissue fixation, excessive time in decalcification solution
Inadequate decalcificationPoor tissue fixation, insufficient time in decalcification solution, inadequate volume of decalcification solution
Uneven section thickness, “thick and thin” sections, “chatter,” “Venetian blind effect”Inadequate decalcification, inadequate microtomy (dull knife blade, improper handwheel tension, improper clearance angle, improper pressure plate or spring balance tension, loose cassette clamp, inadequate decalcification, worn equipment)
Compressed or wrinkled sectionsInadequate microtomy (dull knife blade, warm specimen block, improper clear angle, loose cassette clamp, worn equipment)
“Scratched” or “split” sectionsDefective cutting blade, inadequate decalcification, worn or improperly adjusted microtome
Factors that compromise bone marrow specimen quality There are relatively few published studies evaluating the quality of bone marrow specimens. Bearden et al. considered 1% of bone marrow biopsies and 14% of bone marrow aspirates to be inadequate.[8] Based on the criterion of a minimal biopsy length of 1.5 cm or 5 intertrabecular marrow spaces advocated by Frisch and Bishop et al. considered 59% of their 232 biopsy specimens to be of inadequate length, while Reid and Roald found up to 50% of bone marrow biopsy specimens from children were inadequate.[91011] In contrast, a recent study of 6374 marrow specimens from 32 academic centers showed only 4% of the bone marrow biopsies and 2% of the bone marrow biopsy/bone marrow aspirate samples inadequate for diagnosis.[12 Synoptic reporting, using standardized checklists and data elements, is widely accepted to improve the accuracy and completeness of pathology reports[13] and this format has been facilitated by the cancer checklists and guidelines developed by the CAP.[1213] Based on the CAP checklist, Murari and Pandey proposed synoptic reporting system for bone marrow specimens, in 2006, and a similar synoptic system for hematological and lymphoid neoplasms was devised by Mohanty et al.[1415] Detailed guidelines for the application of the checklist in synoptic bone marrow reporting were subsequently published by the CAP Pathology and Laboratory Quality Center.[4] However, these guidelines do not specifically address the reporting of bone marrow quality parameters.

MATERIALS AND METHODS

A reliable, appropriate, and measurable care initiative identified bone marrow specimen quality as one of the several opportunities for improving the quality of care for patients with leukemia and other hematologic malignancies at our institution. A bone marrow quality improvement committee was formed, and a number of changes were implemented, including the use of a specimen preparation checklist, similar to that developed by Odejide et al., and the establishment of a process for continuous monitoring of bone marrow quality.[3] This process involved the development of specific evidence-based criteria for bone marrow specimen quality, based on the recommendations of the ISLH and CAP, and the incorporation of these criteria into a synoptic reporting system. The synoptic reporting system required bone marrow quality data to be entered into the record of each bone marrow specimen, and data reports to be generated from multiple reports to show location-specific data for a chosen period. The data reports were used by the bone marrow quality improvement committee to identify and implement further changes in the system. The majority of the bone marrow procedures in adult and pediatric outpatients at our institution are performed by specially trained nurse practitioners, while inpatient bone marrow specimens are routinely obtained by the hematology/oncology fellows. A minority of patients with significant obesity or pain sensitivity are referred to interventional radiology for ultrasound-guided procedures under moderate sedation. A few specimens are referred from extramural sources affiliated with our institution. Two or more aspirate smears, two biopsy imprints, and three sections of the trephine biopsy and/or clot were reviewed in all patients, including a few patients who had bilateral biopsies. A major part of the quality improvement initiative was the development of the synoptic method for reporting bone marrow quality during bone marrow specimen sign out. This was done by storing the specimen quality parameters [Table 2] in a relational database integrated into our laboratory information system (Cerner Millennium, Kansas City, MO). In this database, each data item was stored as a predetermined text value referred to as a term, and the collection of such terms constituted the synoptic report. The synoptic report, with convenient drop-down entry boxes to select and record data, was added to our bone marrow report template. Specimen quality data entry was completed during specimen sign out by selecting the appropriate choice from the drop-down box or typing into a text field [Table 3].
Table 2

Bone marrow quality assurance grading parameters

ParameterInadequateSuboptimalAdequate

Bone marrow aspirate
#spiculesNo spicules1-3 spicules>3 spicules or adequate cells without spicules
HemodilutionModerately to severely diluted with blood, compromising interpretationMinimal to mild hemodilution, not compromising interpretationClear background
Cell preservationPoorly preserved, most cells rupturedFocal areas of preserved cellsWell preserved cells
Staining qualityExtensively blurred cellular detailsFocal areas of adequate stainingCrisp nuclear and cytoplasmic detail

Bone marrow biopsy touch imprints

#spiculesNo spicules1-3 spicules>3 spicules or adequate cells without spicules
HemodilutionModerately to severely diluted with blood, compromising interpretationMinimal to mild hemodilution, not compromising interpretationClear background
Cell preservationPoorly preserved, most cells rupturedFocal areas of preserved cellsWell preserved cells
Staining qualityExtensively blurred cellular detailsFocal areas of adequate stainingCrisp nuclear and cytoplasmic detail

Bone marrow biopsy

Total biopsy lengthNo intact marrow tissue<1.6 cm>1.6 cm
Length of interpretable marrowNo intact marrow tissue<1.2 cm>1.2 cm
Aspiration artifactExtensive, moderate to severe, compromising interpretationFocal, minimal to mild, not compromising interpretationNone
Other artifacts (fragmentation, poor sectioning)Extensive, compromising interpretationFocal artifacts, not compromising interpretationNo other artifacts
DecalcificationExtensive undecalcificationFocal underdecalcificationWell decalcified
Staining qualityExtensively blurred cellular detailsFocal areas of adequate stainingCrisp nuclear and cytoplasmic detail
Table 3

Bone marrow quality report components, with terms and available selection choices for each specimen type

Specimen typeTermsSelection choices
Bone marrow aspirate#spiculesInadequate, suboptimal, adequate
HemodilutionModerate/severe, minimal/mild, none
Cell preservationInadequate, suboptimal, adequate
Staining qualityInadequate, suboptimal, adequate
Biopsy touch imprint#spiculesInadequate, suboptimal, adequate
HemodilutionModerate/severe, minimal/mild, none
Cell preservationInadequate, suboptimal, adequate
Staining qualityInadequate, suboptimal, adequate
Bone marrow biopsyArtifactsModerate/severe, minimal/mild, none
FragmentationModerate/severe, minimal/mild, none
DecalcificationInadequate, suboptimal, adequate
Staining qualityInadequate, suboptimal, adequate
Mean lengthNumeric value entry
Interpretable lengthNumeric value entry
Clot section#spiculesInadequate, suboptimal, adequate
Staining qualityInadequate, suboptimal, adequate
Bone marrow quality assurance grading parameters Bone marrow quality report components, with terms and available selection choices for each specimen type Bone marrow quality summary reports were prepared using a Structured Query Language (SQL) query to extract the data from multiple synoptic reports within a specified date range. The extraction process used a proprietary programming language developed by Cerner Corporation called Cerner Command Language (CCL). The CCL compiler converts the program into pure Procedural Language SQL for an Oracle database (Oracle Corporation, Redwood Shores, CA). The entire report is stored as predetermined “terms” in a set of relational tables in the Oracle database as shown in the list as follows: PATHOLOGY_CASE CASE_REPORT AP_CASE_SYNOPTIC_WS SCD_STORY SCD_TERM SCR_TERM SCR_TERM_TEXT SCD_TERM_DATA. The pathology case table contains information about the case. It is used as the starting point in the process of identifying and summarizing the specimen quality criteria. The case report table contains all the reports related to a case. It is joined to the pathology case table using the unique case identifier. The other remaining synoptic-related tables in the list store all of the interrelated terms. There are multiple types of synoptic reports, but the specimen quality report is generated by filtering the AP_CASE_SYNOPTIC_WS table with the ID associated with the specimen quality report. The remaining terms are interrelated and stored in the form of stories. Each of these terms are predetermined and assigned an ID. When a synoptic report is created and completed, the stories and terms are identified and stored in the database. After all the relevant information is identified and extracted, a postextraction process is iterated through each row of the database. Each specimen quality criterion and its scale (term used to actually measure the criteria) are counted and reported in a Microsoft Excel compatible form. For example, in the sample output below, for bone marrow aspirates, #Spicules contained 3 suboptimal, 4 inadequate, and 21 adequate observations [Table 4].
Table 4

Sample output for bone marrow aspirates, showing terms, selection criteria, and scales

Bone marrow aspirates

#SpiculesHemodilutionCell preservationStaining quality
Inadequate: 4Moderate/severe: 5Inadequate: 0Inadequate: 0
Sub-optimal: 3Minimal/mild: 6Sub-optimal: 5Sub-optimal: 0
Adequate: 21None: 17Adequate: 23Adequate: 28
Sample output for bone marrow aspirates, showing terms, selection criteria, and scales Postprocessing was performed on the extracted reports to count the occurrences of specific criteria within the reports, and summarize the counts in tabular format. The data from the tabular report were imported into an Excel Spreadsheet for further processing and the creation of reports for review at quarterly meetings of the bone marrow quality improvement committee. An example of a summary bone marrow quality report generated for August, 2017, to December, 2019, is shown in Figure 1.
Figure 1

Summary bone marrow quality report

Summary bone marrow quality report Finally, the fidelity of content and formatting through correct data transmission was determined in compliance with CAP requirements for both report review and report elements. In all preproduction test runs, the data were received and presented in acceptable formats for the end user, and it was verified that the final data display recapitulated the content and intent of the pathologist's original quality assessment.

RESULTS

The synoptic reporting system to monitor bone marrow quality was developed over a period of 4 years in conjunction with the LIS staff, and went through several iterations before completion in mid-2017. Since August, 2017, the synoptic reporting system has been used to routinely record bone marrow specimen quality from adult patients having procedures in the bone marrow clinic, inpatient wards, and interventional radiology suite of the hospital. From August 1, 2017 to December 30, 2019, data from 3189 adult bone marrow aspirates, 3302 adult core biopsies, and 3183 adult biopsy touch imprints was entered into the synoptic reporting system [Figure 1]. The system was easy to use and did not affect bone marrow real-time reporting or report turnaround times. Across all locations and groups performing bone marrow procedures, hemodilution constituted the most significant finding affecting the quality of bone marrow aspirates and biopsy touch imprints. However, cell preservation was adequate for all specimen types and staining was also of uniformly good quality for all specimen types. The length of the bone marrow cores obtained varied from 12 to 25 mm. Comparing the length of the biopsies for each of the groups performing the procedure, the mean length of the biopsies was approximately 2 cm for specimens obtained by the nurse practitioners and fellows, while those obtained by the interventional radiology service had a mean length of approximately 1.7 cm. Significant (i.e., moderate or severe) aspiration artifact, and traumatic artifact leading to fragmentation and hemorrhage, were the main quality issues identified in approximately 11% of the core biopsies. Of particular note were samples originating from the interventional radiology suite where aspirate samples with a paucity of spicules and significant hemodilution, and biopsies with aspiration artifact and fragmentation were most often encountered. Data obtained from the synoptic system were reviewed at quarterly meetings of the bone marrow quality improvement committee, discussed with the operators, and procedural changes were recommended to decrease aspirate hemodilution and minimize biopsy aspiration artifact and fragmentation. Further modification of the system to obtain operator-specific data is in progress, together with the addition of quality metrics on pediatric bone marrow specimens. The operator-specific data will include the performance of each operator during a selected period for each quality parameter, including the proportion of bone marrow aspirates with hemodilution, and the proportion of biopsy cores with aspiration artifact and fragmentation.

DISCUSSION

Bone marrow specimens of adequate quality are essential for the accurate and timely diagnosis and treatment of patients with a wide variety of diseases. Specimen quality is of increasing importance with the more widespread use of expensive molecular techniques and companion diagnostic procedures. At our institution, improving bone marrow specimen quality was identified as an opportunity to improve the quality of care for patients with hematologic diseases, and the development of a consolidated report-based synoptic data entry and report system permitted continuous monitoring of bone marrow specimen quality. Hemodilution of bone marrow aspirates, aspiration artifacts and fragmentation of the biopsies were the major concerns elucidated through this project as opportunities for quality improvement. The standardized and uniform format of the synoptic report was well received by our clinical colleagues and holds significant potential to initiate further efforts to improve the performance of the bone marrow operators. A modification to the system to provide operator-specific data will permit objective feedback to the proceduralists to improve their performance using six-sigma bench-marking and other types of improvement methodologies.

CONCLUSION

Synoptic reporting has been implemented in multiple pathology subspecialties to improve overall quality, efficiency, and accuracy. The bone marrow quality synoptic reporting system is easy to use, adaptable, and offers distinct advantages in comparison to traditional free-text reporting. Modeled on the criteria recommended by the ISLH and CAP, it offers attributes suitable to the needs of hematopathologists in general with flexibility in the basic design for data entry, customization of protocol-based reports, and data extraction. This study adds to the limited published information regarding the use of a consolidated report-based data entry system for assessing bone marrow specimen quality, an important component of the overall quality assurance process.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  14 in total

1.  A synoptic reporting system for bone marrow aspiration and core biopsy specimens.

Authors:  Manjula Murari; Rakesh Pandey
Journal:  Arch Pathol Lab Med       Date:  2006-12       Impact factor: 5.534

2.  Improving the quality of bone marrow assessment: Impact of operator techniques and use of a specimen preparation checklist.

Authors:  Oreofe O Odejide; Angel M Cronin; Daniel J DeAngelo; Zachary A Bernazzoli; Joseph O Jacobson; Scott J Rodig; Ann S LaCasce; Teresa J Mazeika; Kristofer D Earles; Gregory A Abel
Journal:  Cancer       Date:  2013-08-06       Impact factor: 6.860

3.  Adequacy of bone marrow trephine biopsy specimens in children.

Authors:  M M Reid; B Roald
Journal:  J Clin Pathol       Date:  1996-03       Impact factor: 3.411

4.  Bone Marrow Biopsy Needle Type Affects Core Biopsy Specimen Length and Quality and Aspirate Hemodilution.

Authors:  Jonathan R Brestoff; Angus Toland; Khalid Afaneh; Abraham J Qavi; Barbara Press; Peter Westervelt; Friederike Kreisel; Anjum Hassan
Journal:  Am J Clin Pathol       Date:  2019-01-07       Impact factor: 2.493

Review 5.  Optimal processing of bone marrow trephine biopsy: the Hammersmith Protocol.

Authors:  K N Naresh; I Lampert; R Hasserjian; D Lykidis; K Elderfield; D Horncastle; N Smith; W Murray-Brown; G W Stamp
Journal:  J Clin Pathol       Date:  2006-09       Impact factor: 3.411

6.  Comparison of the diagnostic value of bone marrow biopsy and bone marrow aspiration in neoplastic disease.

Authors:  J D Bearden; G A Ratkin; C A Coltman
Journal:  J Clin Pathol       Date:  1974-09       Impact factor: 3.411

Review 7.  A pathologist's perspective on bone marrow aspiration and biopsy: I. Performing a bone marrow examination.

Authors:  Roger S Riley; Thomas F Hogan; Dawn R Pavot; Robert Forysthe; Davis Massey; Eileen Smith; Lou Wright; Jonathan M Ben-Ezra
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

8.  Synoptic tool for reporting of hematological and lymphoid neoplasms based on World Health Organization classification and College of American Pathologists checklist.

Authors:  Sambit K Mohanty; Anthony L Piccoli; Lisa J Devine; Ashokkumar A Patel; Gross C William; Sharon B Winters; Michael J Becich; Anil V Parwani
Journal:  BMC Cancer       Date:  2007-07-31       Impact factor: 4.430

9.  Trends in Bone Marrow Sampling and Core Biopsy Specimen Adequacy in the United States and Canada: A Multicenter Study.

Authors:  Mihai Merzianu; Adrienne Groman; Alan Hutson; Claudiu Cotta; Russell K Brynes; Attilio Orazi; Vishnu Reddy; Julie Teruya-Feldstein; Ramila Amre; Manjula Balasubramanian; Guilherme Brandao; Sindhu Cherian; Elizabeth Courville; David Czuchlewski; Guang Fan; David Grier; Daniela Hoehn; Kedar V Inamdar; Ridas Juskevicius; Prabhjot Kaur; John Lazarchick; Michael R Lewis; Rodney R Miles; Jerome B Myers; Michel R Nasr; Hina N Qureishi; Horatiu Olteanu; Valentin G Robu; Gratian Salaru; Neerja Vajpayee; Jeffrey Vos; Ling Zhang; Shanxiang Zhang; Le Aye; Elisa Brega; James E Coad; John Grantham; Sinisa Ivelja; Robert McKenna; Kieran Sultan; Gregory Wilding; Robert Hutchison; LoAnn Peterson; Richard T Cheney
Journal:  Am J Clin Pathol       Date:  2018-10-01       Impact factor: 2.493

10.  Bone Marrow Biopsy Operator Experience and Impact on Aspirate, Biopsy, and Ancillary Testing Quality.

Authors:  Lisa M Marinelli; Hong Fang; Matthew T Howard; Curtis A Hanson; Joseph J Haack; Edward A Eick; Richard J Allen; David E Ruffridge; Colleen M Byrne; Rebecca L King
Journal:  Mayo Clin Proc Innov Qual Outcomes       Date:  2018-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.