Abstract
OBJECTIVES: Bone marrow evaluation plays a critical role in the diagnosis, staging, and monitoring of many diseases. Although there are standardized guidelines for assessing bone marrow specimen quality, there is a lack of evidence-based tools to perform such assessments. The objective was to monitor bone marrow sample quality in real time by standardizing the basic components of a synoptic report and incorporating it into a bone marrow report template.Entities:
Keywords: Bone marrow specimen quality; laboratory information management system; pathology informatics; synoptic reporting
Year: 2021 PMID: 34447603 PMCID: PMC8356705 DOI: 10.4103/jpi.jpi_53_20
Source DB: PubMed Journal: J Pathol Inform
Factors that compromise bone marrow specimen quality
| Specimen | Artifact | Cause |
|---|---|---|
| Bone marrow aspiration | Suboptimal staining | Old or contaminated staining solution, inadequate staining time |
| Inadequate particles | Poor aspiration technique, “dry tap” | |
| Cell crushing and distortion | Inadequate training, improper procedure | |
| Thick smears | Clotted specimen, inadequate training, improper procedure | |
| Uneven cell distribution | Clotted specimen, inadequate training, improper procedure | |
| Clotted specimen | Poor technique, multiple aspiration attempts with local activation of coagulation system, hyperactive coagulation system | |
| Bone marrow biopsy | Aspiration artifact | Biopsy of aspiration site, failure to obtain aspirate and biopsy specimens from different areas |
| Suboptimal staining | Inadequate fixation of processing, expired or contaminated staining solution | |
| Biopsy of previous aspiration or biopsy site | Failure to reorient biopsy needle at a proper angle or to a proper site | |
| Crushed or fragmented specimen | Harsh handling during touch imprint preparation or processing, inadequate microtomy | |
| Inadequate fixation | Inadequate volume of fixative solution, inadequate fixation time | |
| Excessive decalcification | Poor tissue fixation, excessive time in decalcification solution | |
| Inadequate decalcification | Poor tissue fixation, insufficient time in decalcification solution, inadequate volume of decalcification solution | |
| Uneven section thickness, “thick and thin” sections, “chatter,” “Venetian blind effect” | Inadequate decalcification, inadequate microtomy (dull knife blade, improper handwheel tension, improper clearance angle, improper pressure plate or spring balance tension, loose cassette clamp, inadequate decalcification, worn equipment) | |
| Compressed or wrinkled sections | Inadequate microtomy (dull knife blade, warm specimen block, improper clear angle, loose cassette clamp, worn equipment) | |
| “Scratched” or “split” sections | Defective cutting blade, inadequate decalcification, worn or improperly adjusted microtome |
Bone marrow quality assurance grading parameters
| Parameter | Inadequate | Suboptimal | Adequate |
|---|---|---|---|
|
| |||
| Bone marrow aspirate | |||
| #spicules | No spicules | 1-3 spicules | >3 spicules or adequate cells without spicules |
| Hemodilution | Moderately to severely diluted with blood, compromising interpretation | Minimal to mild hemodilution, not compromising interpretation | Clear background |
| Cell preservation | Poorly preserved, most cells ruptured | Focal areas of preserved cells | Well preserved cells |
| Staining quality | Extensively blurred cellular details | Focal areas of adequate staining | Crisp nuclear and cytoplasmic detail |
|
| |||
|
| |||
|
| |||
| #spicules | No spicules | 1-3 spicules | >3 spicules or adequate cells without spicules |
| Hemodilution | Moderately to severely diluted with blood, compromising interpretation | Minimal to mild hemodilution, not compromising interpretation | Clear background |
| Cell preservation | Poorly preserved, most cells ruptured | Focal areas of preserved cells | Well preserved cells |
| Staining quality | Extensively blurred cellular details | Focal areas of adequate staining | Crisp nuclear and cytoplasmic detail |
|
| |||
|
| |||
|
| |||
| Total biopsy length | No intact marrow tissue | <1.6 cm | >1.6 cm |
| Length of interpretable marrow | No intact marrow tissue | <1.2 cm | >1.2 cm |
| Aspiration artifact | Extensive, moderate to severe, compromising interpretation | Focal, minimal to mild, not compromising interpretation | None |
| Other artifacts (fragmentation, poor sectioning) | Extensive, compromising interpretation | Focal artifacts, not compromising interpretation | No other artifacts |
| Decalcification | Extensive undecalcification | Focal underdecalcification | Well decalcified |
| Staining quality | Extensively blurred cellular details | Focal areas of adequate staining | Crisp nuclear and cytoplasmic detail |
Bone marrow quality report components, with terms and available selection choices for each specimen type
| Specimen type | Terms | Selection choices |
|---|---|---|
| Bone marrow aspirate | #spicules | Inadequate, suboptimal, adequate |
| Hemodilution | Moderate/severe, minimal/mild, none | |
| Cell preservation | Inadequate, suboptimal, adequate | |
| Staining quality | Inadequate, suboptimal, adequate | |
| Biopsy touch imprint | #spicules | Inadequate, suboptimal, adequate |
| Hemodilution | Moderate/severe, minimal/mild, none | |
| Cell preservation | Inadequate, suboptimal, adequate | |
| Staining quality | Inadequate, suboptimal, adequate | |
| Bone marrow biopsy | Artifacts | Moderate/severe, minimal/mild, none |
| Fragmentation | Moderate/severe, minimal/mild, none | |
| Decalcification | Inadequate, suboptimal, adequate | |
| Staining quality | Inadequate, suboptimal, adequate | |
| Mean length | Numeric value entry | |
| Interpretable length | Numeric value entry | |
| Clot section | #spicules | Inadequate, suboptimal, adequate |
| Staining quality | Inadequate, suboptimal, adequate |
Sample output for bone marrow aspirates, showing terms, selection criteria, and scales
| Bone marrow aspirates | |||
|---|---|---|---|
|
| |||
| #Spicules | Hemodilution | Cell preservation | Staining quality |
| Inadequate: 4 | Moderate/severe: 5 | Inadequate: 0 | Inadequate: 0 |
| Sub-optimal: 3 | Minimal/mild: 6 | Sub-optimal: 5 | Sub-optimal: 0 |
| Adequate: 21 | None: 17 | Adequate: 23 | Adequate: 28 |
Figure 1Summary bone marrow quality report