Literature DB >> 34427250

iStent versus iStent inject implantation combined with phacoemulsification in open angle glaucoma.

Wesam Shamseldin Shalaby1, Sophia S Lam2, Amirmohsen Arbabi3, Jonathan S Myers3, Marlene R Moster3, Natasha N Kolomeyer3, Reza Razeghinejad3, Aakriti Garg Shukla3, Tarek R Hussein4, Tarek M Eid4, Said M Shalaby4, Daniel Lee3.   

Abstract

PURPOSE: To compare the outcomes of iStent vs. iStent inject implantation combined with phacoemulsification.
METHODS: This single center retrospective comparative case series included subjects with open angle glaucoma who underwent iStent or iStent inject implantation combined with phacoemulsification with ≥1 year follow-up. The main outcome measures were in-group and between-group changes in intraocular pressure (IOP) and medication number, proportion of eyes that achieved IOP ≤15 mmHg, and surgical success defined as 20% IOP reduction from baseline at 6/12 months. Univariate/multivariate regression analyses were done to identify predictors of surgical failure.
RESULTS: One hundred ninety-seven eyes of 148 patients were included (122 iStent, 75 iStent inject). Both groups achieved significant IOP and medication reduction at months 6/12 (P < 0.05). At month 6, IOP was significantly lower in iStent inject vs. iStent eyes (P = 0.003), but the difference was insignificant by month 12 (P = 0.172). Medication number was comparable in both groups at months 6/12 (P > 0.05). More iStent inject eyes achieved IOP ≤15 mmHg at month 6 (P = 0.003) and 12 (P = 0.047). Surgical success was comparable in both groups at months 6/12 (P > 0.05). Kaplan-Meier survival analysis showed similar cumulative rate of surgical failure at year-1 in both groups (P = 0.644). The multivariate model identified older age (P = 0.017) and lower baseline IOP (P = 0.002) as the strongest predictors of surgical failure.
CONCLUSION: Compared to iStent, iStent inject achieved lower IOP at month 6 and higher proportion of eyes achieved IOP ≤15 mmHg at month 6/12. However, surgical success was similar in both groups. Predictors of surgical failure were older age and lower baseline IOP rather than the stent type.

Entities:  

Keywords:  iStent; iStent inject; minimally invasive glaucoma surgery; open angle glaucoma; phacoemulsification; trabecular microbypass stent

Mesh:

Year:  2021        PMID: 34427250      PMCID: PMC8544096          DOI: 10.4103/ijo.IJO_308_21

Source DB:  PubMed          Journal:  Indian J Ophthalmol        ISSN: 0301-4738            Impact factor:   1.848


Glaucoma is a leading cause of irreversible blindness worldwide.[12] Elevated intraocular pressure (IOP) is one of the major risk factors for development and progression of open angle glaucoma (OAG) and its reduction is considered the only intervention proved to slow progression of the disease.[3] IOP reduction is currently achieved by topical hypotensive medications, laser therapy, or incisional surgical procedures. However, poor compliance and tolerability have been an issue with medications,[4] and serious complications have been associated with incisional surgeries.[5] Recently, minimally invasive glaucoma surgeries have emerged to provide safer and effective IOP reduction.[6] Trabecular microbypass stents work by improving conventional trabecular outflow through Schlemm’s canal, bypassing the trabecular meshwork, which is considered the major site of aqueous outflow resistance in OAG.[7] iStent® (Glaukos Corporation, Laguna Hills, CA, USA) was the first trabecular microbypass stent to be approved in the United States. Several studies have proved its efficacy and safety either as a solo procedure[8910] or combined with phacoemulsification.[111213] Further studies comparing the effect of single vs. multiple stent implantation have reported increasing therapeutic efficacy with each additional stent.[141516] The second generation iStent inject® (Glaukos Corporation, Laguna Hills, CA, USA) was developed with a modified injector allowing surgeons to implant both stents with a single entry into the eye. The head of the device has four side outlets in addition to the central one, theoretically allowing multidirectional aqueous outflow.[17] The device is also designed for a simplified surgical technique compared to the first generation. iStent inject efficacy and safety have been studied either standalone[181920212223242526] or combined with phacoemulsification.[172728293031323334] However, the literature comparing both devices is relatively limited.[35363738]

Methods

Study design

This was a single-center, retrospective comparative case series. The study was approved by the Institutional Review Board of Wills Eye Hospital in December 2020 and was in accordance with Health Insurance Portability and Accountability Act regulations. As this was a retrospective study with deidentified data, informed consent was not required. The medical records of consecutive patients who underwent phacoemulsification combined with iStent or iStent inject implantation for OAG at Wills Eye Hospital between 2016 and 2019 were reviewed. Patients were matched for age and baseline visual acuity (VA), IOP, and medication number.

Inclusion and exclusion criteria

Patients aged ≥18 years diagnosed with OAG including primary open angle glaucoma (POAG), pigmentary glaucoma (PG), pseudoexfoliation glaucoma, and normal tension glaucoma (NTG) were included. Preoperative glaucoma diagnosis and severity were based on the American Academy of Ophthalmology and Medicare International Statistical Classification of Diseases and Related Health Problems diagnosis criteria.[39] Eyes with prior intraocular surgery or less than 1-year follow-up were excluded. Due to its relatively recent approval, iStent inject eyes that completed 6-month follow-up were also included for month-6 analysis.

Patient visits

Visits at baseline, postoperative day 1, week 1, months 1, 3, 6, and 12 were reviewed from electronic medical records. Demographic data including age, sex, and race as well as glaucoma type and severity were collected. Preoperative clinical data included VA, IOP, topical glaucoma medications, cup to disc ratio, and gonioscopy findings. Postoperative data included VA, IOP, glaucoma medications, postoperative complications, and need for additional glaucoma surgery.

Surgical procedure

Seven surgeons at Wills Eye Hospital participated in this study. The choice of the stent was based on the availability of iStent only before 2018 and the surgeon preference following iStent inject release. Device implantation occurred after phacoemulsification. Through a temporal clear corneal incision and under direct-gonioscopic visualization, the self-trephinating tip of the iStent was used to penetrate the trabecular meshwork. Once the device was placed in the Schlemm’s canal, the inserter button was depressed to release the device. The inserter tip was used to fully drive the iStent into the canal [Fig. 1, Supplementary Video 1]. For iStent inject, the sleeve of the injector was retracted, revealing the trocar and microinsertion tube. The trocar was penetrated through the trabecular meshwork, and the delivery button was depressed to implant the first stent and the second stent placed 2–3 clock hours away [Fig. 2, Supplementary Video 2].
Figure 1

Intraoperative gonioscopic view of Single iStent. (a) iStent in the injector before implantation (arrow). (b) iStent successfully implanted in the Schlemm’s canal (arrow). Courtesy of Dr Reza Razeghinejad, Glaucoma Service, Wills Eye Hospital

Figure 2

Intraoperative gonioscopic view of double iStent inject. (a) The first iStent inject embedded in the Schlemm’s canal (red arrow) and the second one in the injector before implantation (yellow arrow). (b) Both iStent inject devices are successfully implanted in the Schlemm’s canal (arrows). Courtesy of Dr Reza Razeghinejad, Glaucoma Service, Wills Eye Hospital

Intraoperative gonioscopic view of Single iStent. (a) iStent in the injector before implantation (arrow). (b) iStent successfully implanted in the Schlemm’s canal (arrow). Courtesy of Dr Reza Razeghinejad, Glaucoma Service, Wills Eye Hospital Intraoperative gonioscopic view of double iStent inject. (a) The first iStent inject embedded in the Schlemm’s canal (red arrow) and the second one in the injector before implantation (yellow arrow). (b) Both iStent inject devices are successfully implanted in the Schlemm’s canal (arrows). Courtesy of Dr Reza Razeghinejad, Glaucoma Service, Wills Eye Hospital

Outcome measures

The primary outcome measures were in-group and between-group comparisons of IOP and medication number, proportions of eyes that achieved the effectiveness endpoint as IOP ≤15 mmHg, and surgical success defined as 20% or more IOP reduction from the baseline at 6 and 12 months. Predictors of failure were analyzed using univariate and multivariate regression analyses. Safety measures included intraoperative and postoperative adverse events, need for reoperation for complications or glaucoma, and changes in VA.

Statistical analysis

Statistical analyses were performed using SPSS software version 27.0 (IBM Analytics, Chicago, IL, USA). Snellen VA measurements were converted to logarithm of the minimum angle of resolution (logMAR) VA equivalents for the purpose of data analysis. Continuous variables were presented as mean ± standard deviation. Proportions (%) were used to describe categorical variables. Two-sided Student’s t-tests and Chi-square tests (Fisher exact tests) were used to compare treatment groups for continuous and categorical variables, respectively. Paired sample t-tests and McNemar test were used to compare continuous and categorical variables within the same group, respectively. Analysis of covariance was performed for between-group comparisons after adjusting for the baseline characteristics. P values < 0.05 were considered significant. Kaplan–Meier survival analysis with log-rank tests were used to report cumulative rate of surgical failure. Logistic regression analysis was performed to identify factors predictive of surgical failure. Variables in the univariate analysis with P values ≤ 0.2 were entered into the multivariate regression model using the forward stepwise Wald method. Hazard ratios and 95% confidence intervals were generated for both univariate and multivariate regression models. Estimation of sample size (80% power and an alpha of 0.05) was performed by considering prior outcomes from a retrospective comparative case series, which detected a significantly greater IOP reduction for iStent inject eyes than for iStent eyes at month 12 with a sample size of 70 and 67 in each study group, respectively.[36] A mixed effect linear model was done to account for the use of two eyes from a single patient with the surgical eye variable was added as a random effect.

Results

Baseline characteristics

One hundred ninety-seven eyes of 148 patients were included (122 iStent, 75 iStent inject). Baseline characteristics are displayed in . Age, sex, and ocular characteristics were comparable between groups. White race was predominant in the iStent group and represented 73.5%, while Black individuals were more prevalent in the iStent inject group and represented 42.0% (P < 0.001). POAG was the most common diagnosis (82.7%) with no difference between groups (P = 0.956). Most of eyes (91.4%) had mild to moderate disease with no difference between groups (P = 0.929). All patients completed 6-month follow-up. By month 12, all iStent eyes (N = 122) and only 60/75 of the iStent inject eyes were available for the analysis. Baseline Characteristics in the iStent and iStent inject Groups POAG: primary open angle glaucoma, PG: pigmentary glaucoma, PXG: Pseudoexfoliation glaucoma, and NTG: normal tension glaucoma

Intraocular pressure

Both study groups experienced significant IOP reduction through months 6 and 12. Mean IOP in the iStent eyes was reduced from 16.2 ± 2.9 mmHg at baseline to 14.9 ± 3.6 mmHg at month 6 (1.3 ± 3.4 mmHg IOP reduction, P < 0.001) and to 15.1 ± 3.5 mmHg at month 12 (1.1 ± 3.3 mmHg IOP reduction, P < 0.001). In iStent inject group, mean IOP was reduced from 15.4 ± 4.4 at baseline to 13.2 ± 3.9 mmHg at month 6 (2.2 ± 4.1 mmHg IOP reduction, P < 0.001). By month 12, the available 60 iStent inject eyes maintained significantly lower IOP (14.0 ± 5.2) mmHg compared to their baseline (1.5 ± 5.0 IOP reduction, P = 0.023). Months 6 and 12 outcomes of both study groups are displayed in Table 2.
Table 2

In-group Comparison of Month 6 and Month 12 Outcomes in the iStent and iStent inject Groups

BaselineMonth 6Difference P
iStent (n=122)
Visual Acuity: LogMAR0.31±0.330.17±0.380.15±0.33< 0.001
Intraocular Pressure: mmHg16.2±2.914.9±3.61.3±3.4< 0.001
Medication Number2.0±1.01.3±1.00.7±0.9< 0.001
iStent inject (n=75)
Visual Acuity: LogMAR0.38±0.380.17±0.370.21±0.22< 0.001
Intraocular Pressure: mmHg15.4±4.413.2±3.92.2±4.1< 0.001
Medication Number1.7±1.11.4±1.10.3±1.10.014

Baseline Month 12 Difference P

iStent (n=122)
Visual Acuity: LogMAR0.31±0.330.17±0.370.14±0.32< 0.001
Intraocular Pressure: mmHg16.2±2.915.1±3.51.1±3.3< 0.001
Medication Number2.0±1.01.3±1.00.7±0.9< 0.001
iStent inject (n=60)
Visual Acuity: LogMAR0.41±0.400.17±0.370.24±0.24< 0.001
Intraocular Pressure: mmHg15.6±4.714.0±5.21.5±5.00.023
Medication Number1.9±1.11.5±1.20.4±1.10.011
Visual Field Mean Deviation: dB-8.9±4.9-7.5±5.0-1.4±3.80.013
In-group Comparison of Month 6 and Month 12 Outcomes in the iStent and iStent inject Groups Regarding between-group comparison, the IOP was significantly lower in the iStent inject compared to the iStent eyes at month 6 (P = 0.003), and this difference remained significant even after adjusting for the baseline IOP using analysis of covariance testing. However, this significant difference was not maintained by month 12 (P = 0.172). Fig. 3a shows IOP changes in both groups over time. Proportion of eyes with IOP ≤15 mmHg was significantly higher in the iStent inject group (70.7%) compared to the iStent group (49.2%) (P = 0.003) at month 6. The same trend continued through month 12, with significantly higher proportions of iStent inject eyes (61.4%) maintained IOP ≤15 mmHg as compared to 46.7% of iStent eyes (P = 0.047).
Figure 3

(a) Intraocular pressure changes over time in the iStent and iStent inject groups. iStent inject eyes had significantly lower intraocular pressure in the first 6 months. At month 12, the difference was insignificant. (b) Medication number changes over time in the iStent and iStent inject groups. Both groups had similar medication number at all postoperative visits

(a) Intraocular pressure changes over time in the iStent and iStent inject groups. iStent inject eyes had significantly lower intraocular pressure in the first 6 months. At month 12, the difference was insignificant. (b) Medication number changes over time in the iStent and iStent inject groups. Both groups had similar medication number at all postoperative visits At month 6, 50.8% of the iStent eyes and 60.0% of the iStent inject eyes achieved surgical success defined as 20% or more IOP reduction, but this difference was insignificant (P = 0.240). By month 12, lower proportions in both groups maintained 20% IOP reduction (47.5 and 50.0%, respectively; P = 0.875). Kaplan–Meier survival analysis [Fig. 4] comparing cumulative rate of surgical failure between iStent (N = 122) and iStent inject (N = 75) eyes at 1 year revealed no difference between the groups (P = 0.644).
Figure 4

Kaplan–Meier survival curve of surgical failure in the iStent and iStent inject groups. Both groups demonstrated similar cumulative rate of failure over 1 year

Kaplan–Meier survival curve of surgical failure in the iStent and iStent inject groups. Both groups demonstrated similar cumulative rate of failure over 1 year Based on findings from the univariate regression analysis, a multivariate model including age, sex, baseline IOP, and baseline cup to disc ratio was created [Table 3]. This model (P < 0.001) demonstrated that older age (P = 0.017) and lower baseline IOP (P = 0.002) were the strongest predictors of surgical failure at month 12. Race, glaucoma type, and stent type were not significant predictors of surgical failure. Although female sex (P = 0.027) and eyes with smaller cup to disc ratio (P = 0.088) tended to have more failure in the univariate analysis, these covariates were insignificant in the multivariate model.
Table 3

Predictors of Month 12 Surgical Failure Using Univariate and Multivariate Logistic Regression Analysis

Univariate AnalysisSuccess n=88Failure n=94Wald P Hazard Ratio95% Confidence Interval
Demographics
Age: Years74.5±8.876.5±7.92.7180.0991.0310.994-1.068
Sex, Female: n (%)47 (53.4)64 (68.1)4.9130.0271.9881.083-3.649
Race n (%)White65 (73.9)74 (78.7)
Black15 (17.0)18 (19.1)0.7220.3960.8370.555-1.262
Asian5 (5.7)1 (1.1)
Others3 (3.4)1 (1.1)
Etiology
Glaucoma Type: n (%)POAG75 (85.2)77 (81.9)1.6280.2020.8980.760-1.060
PG3 (3.4)1 (1.1)
PXG5 (5.7)4 (4.3)
NTG5 (5.7)12 (12.7)
Baseline Intraocular Pressure: mmHg16.7±3.615.3±3.46.2190.0130.8940.819-0.976
Baseline Cup to Disc Ratio0.7±0.20.6±0.22.9070.0880.1380.014-1.344
Surgery
Surgery Type: n (%)iStent58 (65.9)64 (68.1)0.0000.9831.0070.536-1.890
iStent inject30 (34.1)30 (31.9)

Multivariate Analysis P<0.001 Success n=85 Failure n=94 Wald P Hazard Ratio 95% Confidence Interval

Age: Years74.5±8.876.5±7.95.7230.0171.1111.019-1.210
Sex, Female: n (%)47 (53.4)64 (68.1)0.3920.5311.6150.360-7.244
Baseline Intraocular Pressure: mmHg16.7±3.615.3±3.49.1440.0020.7080.566-0.885
Baseline Cup to Disc Ratio0.7±0.20.6±0.21.4610.2110.0150.000-2.170

POAG: primary open angle glaucoma, PG: pigmentary glaucoma, PXG: Pseudoexfoliation glaucoma, NTG: normal tension glaucoma, and IOP: intraocular pressure

Predictors of Month 12 Surgical Failure Using Univariate and Multivariate Logistic Regression Analysis POAG: primary open angle glaucoma, PG: pigmentary glaucoma, PXG: Pseudoexfoliation glaucoma, NTG: normal tension glaucoma, and IOP: intraocular pressure A mixed effect linear model was done to account for the use of two eyes from a single patient. This model showed that the surgical eye (right vs. left) was not a significant covariate for month 12 surgical failure (P = 0.853) effectively nullifying which eye/eyes were picked for each patient since it is random.

Medical therapy

There was a significant reduction in the need for medical therapy in both treatment groups through months 6 and 12. Mean number of glaucoma medications in the iStent group decreased from 2.0 ± 1.0 at baseline to 1.3 ± 1.0 at month 6 and remained the same at month 12 (0.7 ± 0.9 medication reduction, P < 0.001). Mean number of glaucoma medications in the iStent inject group decreased from 1.7 ± 1.1 at baseline to 1.4 ± 1.1 at month 6 (0.3 ± 1.1 medication reduction, P = 0.014). At month 12, the available 60 iStent inject eyes maintained lower number of medications 1.5 ± 1.2 compared to their baseline 1.9 ± 1.1 (0.4 ± 1.1 medication reduction, P = 0.011). Between-group comparison showed no significant difference in the medication number at monthS 6 (P = 0.547) and 12 (P = 0.391). Fig.3b shows medication number in both groups over time. Similar proportions of eyes in iStent vs. iStent inject groups were medication free at months 6 (30.3% vs. 26.7%, P = 0.630) and month 12 (28.7% vs. 25%, P = 0.724).

Visual acuity and visual field

VA significantly improved postoperatively [Table 2] with no difference between groups at month 6 (P = 0.432) and 12 (P = 0.967), which is consistent with expectations of combined cataract surgery. In the iStent group, mean LogMAR VA increased from 0.31 ± 0.33 at baseline to 0.17 ± 0.38 at month 6 (P < 0.001) and 0.17 ± 0.37 at month 12 (P < 0.001). In the iStent inject group, mean LogMAR VA increased from 0.38 ± 0.3 at baseline to 0.17 ± 0.37 at month 6 (P < 0.001), also eyes completed month 12 follow-up showed significant improvement in VA (0.17 ± 0.37) compared to their baseline (0.41 ± 0.40) (P < 0.001). Visual field mean deviation showed significant improvement at month 12 in both the iStent (P = 0.011) and iStent inject (P = 0.013) groups compared to their baseline [Table 2]. This improvement may be related to improvement of generalized sensitivity following cataract surgery and rules out progression of glaucoma.

Safety

Both iStent and iStent groups demonstrated high safety profile. Intraoperative adverse events were minimal. Blood reflux was observed in five (4.1%) iStent eyes and two (2.7%) iStent inject eyes. Failure to implant the second stent occurred in seven (9.3%) iStent inject eyes. Posterior capsular rupture and anterior vitrectomy occurred in one iStent inject eye, and both stents were successfully implanted. Early postoperative complications including hyphema, corneal edema, and iritis were mild and transient in both groups. Postoperative day 1 pressure spikes defined as 10 mmHg IOP rise as compared to the baseline were significantly higher in the iStent vs. iStent inject group (11.5% vs. 2.7%, respectively; P = 0.032). Only one iStent inject eye developed postcataract cystoid macular edema that required repeated posterior subtenon triamcinolone injection. Otherwise, no eyes experienced decline in the VA at any time point postoperatively. By month 12, reoperation for glaucoma was not required for any iStent inject eyes, while two iStent eyes underwent invasive glaucoma surgery for uncontrolled IOP (trabeculectomy and tube shunt).

Discussion

This single-center retrospective comparative case series demonstrated that iStent and iStent inject devices combined with phacoemulsification effectively and safely reduced IOP and medication number over 1 year in OAG. The results showed favorable iStent inject outcomes vs. iStent in terms of lower IOP at month 6 and higher proportion of eyes with IOP ≤ 15 mmHg at months 6 and 12. However, surgical success was comparable in both groups at months 6 and 12. Multivariate regression model (P < 0.001) identified older age (P = 0.034) and lower baseline IOP (P = 0.003) as the strongest predictors of surgical failure at month 12. Theoretically, iStent inject may have better efficacy given the modified design and the advantage of simultaneous implantation of two stents, which was shown to provide more IOP reduction in prior iStent studies that investigated the effect of multiple stent implantation.[141516] However, direct comparisons between both devices were not conclusive.[35363738] Our study used several criteria to compare both devices (mean IOP and medication number, IOP ≤ 15 mmHg, and 20% IOP reduction) at two time points (months 6 and 12) and could not detect consistent superiority of iStent inject with all criteria at all time points. The literature contains several studies on iStent and iStent inject with varying results. In a similar prospective comparative case series with 245 POAG eyes, mean IOP at month 12 was similar between groups, which was similar to our month-12 outcomes. Likewise, surgical success was similar with 56.0% of the iStent vs. 51.3% of the iStent inject eyes had achieved primary success (IOP ≤ 18 mmHg without medications) and 63.1% vs. 57.7% had achieved secondary success (IOP ≤ 18 mmHg with medication reduction).[35] Manning et al.,[36] retrospectively included 137 eyes. At month-12, mean IOP was significantly reduced in both groups compared to baseline. The IOP reduction was significantly greater for iStent inject eyes than iStent eyes. Although our study demonstrated favorable IOP in the iStent inject group at month 6, the difference was insignificant by month 12 in contrast to this study. Both groups had high proportions of patients achieving IOP ≤18 mmHg, with greater proportions with iStent inject than iStent. Although we used IOP ≤15 mmHg as effectiveness endpoint giving the lower baseline IOP, we agreed with this study that more iStent inject eyes achieved the effectiveness endpoint as compared with iStent. Consistent with our results, both groups achieved significant medication reduction at month 12. However, a significantly higher proportion of iStent inject eyes were medication free, which was in contrast to our study that showed similar proportions of medication free eyes in both groups. Another retrospective study showed conclusion in favor to iStent inject, with inclusion of 58 OAG eyes. At month 12, iStent inject eyes achieved significant IOP reduction, while iStent eyes did not. Mean IOP reduction was significantly greater in iStent inject eyes in contrast to our study that showed similar month-12 IOP in both groups. Similar to ours, both groups achieved significant medication reduction at month 12, but iStent inject eyes had a significantly lower medication number and more medication free eyes, which was in contrast to our results that showed similar medication number and medication free eyes in both groups.[37] The authors published the 6-month results in a separate cohort, as more patients were available for analysis (N = 73).[38] The results were comparable to our 6-month outcomes, with better IOP reduction in the iStent inject group and significantly more iStent inject eyes achieved IOP ≤18 mmHg. Our study showed similar surgical success in both groups defined as 20% IOP reduction from the baseline at months 6 and 12. The multivariate model identified older age and lower baseline IOP as the strongest predictors of surgical failure at month 12 rather than the stent type. These findings demonstrated that the efficacy of trabecular stents may be augmented in eyes with higher IOP, in which the high-pressure gradient across the stent endings may lead to more aqueous outflow and subsequently more IOP reduction unlike eyes with low baseline IOP, in which the pressure gradient may not have been high enough to allow significant aqueous outflow through the stent. Likewise, eyes with NTG showed more failure at 1 year (12 failed vs. 5 successful eyes). Although this was statistically insignificant, it is in line with lower baseline IOP associated with higher failure. These findings were also similar to the outcomes of Salimi et al.,[32] study that added a linear regression model to identify predictors of postoperative IOP. The model showed that greater baseline preoperative IOP and thinner corneas were associated with higher IOP reduction. Although our study was not powered to provide subgroup comparison, the regression analysis showed that glaucoma type was insignificant predictor of surgical failure. Compared to Klamann’s study,[24] they reported 100% failure in the PG, suggesting that iStent inject in phakic PG may have limitations. However, similarly, Klamann’s study was not powered to detect differences between glaucoma types, and further larger sample studies are required. Similar to existing literature, both iStent and iStent inject demonstrated high safety profiles. Intraoperative complications were minimal and similar in both groups and included blood reflux, which is considered a sign of correct position and patency of the stent and was reported in prior studies.[24252740] Failure to implant the second stent occurred in 9.3% of iStent inject eyes, which was comparable to prior studies.[17283136] Postoperative adverse events were transient and required no additional interventions. Only two eyes required reoperation for glaucoma, which was similar to the reoperation rate in prior studies.[171923243133373840]

Conclusion

Both iStent and iStent inject combined with phacoemulsification have effectively and safely reduced IOP and medication number over 1 year. Although iStent inject achieved lower IOP at month 6, both groups had similar IOP at month 12. Effectiveness endpoint as IOP ≤15 mmHg was achieved in more iStent inject eyes at months 6 and 12. However, surgical success defined as 20% IOP reduction was similar in both groups. Predictors of surgical failure were older age and lower baseline IOP, rather than the stent type.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

Financial Disclosure:

WSS: None. SSL: None. AA: None. JSM: Consultant: Aerie, Allergan, Glaukos, MicroOptx, Olleyes; Speaker: Aerie, Allergan, Haag Streit; Research: Aerie, Allergan, Glaukos, Diopsys, Haag Streit, Nicox, Olleyes, Santen MRS: Consultant: Alcon, Allergan, Bausch and Lomb, Glaukos, Aerie, and Qura; Speaker: Alcon, Allergan, Aerie, and Bausch and Lomb. NNK: Research: Allergan, Inc. RR: None. AGS: American Glaucoma Society Mentoring for Advancement of Physician Scientists Grant. TRH: None TME: None SMS: None DL: Consultant: Allergan, Inc. Research: Allergan, Inc. Speaker: Glaukos Corp.
Table 1

Baseline Characteristics in the iStent and iStent inject Groups

iStent n=98iStent inject n=50Total n=148 P
Age: Years76.3±7.873.5±8.375.3±8.10.100
Sex, Females: n (%)52 (53.1)31 (62.0)83 (56.1)0.382
Race: n (%)White72 (73.5)19 (38.0)91 (61.5)< 0.001
Black18 (18.4)21 (42.0)39 (26.4)
Asian5 (5.1)5 (10.0)10 (6.8)
Others3 (3.1)5 (10.0)8 (5.4)

iStent n=122 iStent inject n=75 Total n=197 P

Study Eye, Right: n (%)58 (47.5)37 (49.3)95 (48.2)0.883
Glaucoma Type: n (%)POAG100 (82.0)63 (84.0)163 (82.7)0.956
PG3 (2.5)2 (2.7)5 (2.5)
PXG7 (5.7)3 (4.0)10 (5.1)
NTG12 (9.8)7 (9.3)19 (9.7)
Glaucoma SeverityMild49 (40.2)32 (42.7)81 (41.1)0.929
Moderate62 (50.8)37 (49.3)99 (50.3)
Severe11 (9.0)6 (8.0)17 (8.6)
Visual Acuity: LogMAR0.31±0.330.38±0.380.34±0.350.152
Intraocular Pressure: mmHg16.2±2.915.4±4.415.9±3.50.171
Medication Number2.0±1.01.7±1.11.9±1.00.100
Cup to Disc Ratio0.6±0.20.7±0.20.7±0.20.323
Visual Field Mean Deviation: dB-9.1±5.3-8.9±4.9-9.0±5.10.978
Retinal Nerve Fiber Layer Thickness: Microns69.1±10.070.2±10.169.5±9.90.899
Central Corneal Thickness: Microns532.0±26.0528.0±24.0530.0±25.00.911

POAG: primary open angle glaucoma, PG: pigmentary glaucoma, PXG: Pseudoexfoliation glaucoma, and NTG: normal tension glaucoma

  39 in total

1.  Glaucoma is second leading cause of blindness globally.

Authors:  Sharon Kingman
Journal:  Bull World Health Organ       Date:  2004-12-14       Impact factor: 9.408

2.  Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.

Authors:  Thomas W Samuelson; Steven R Sarkisian; David M Lubeck; Michael C Stiles; Yi-Jing Duh; Eeke A Romo; Jane Ellen Giamporcaro; Dana M Hornbeak; L Jay Katz
Journal:  Ophthalmology       Date:  2019-03-14       Impact factor: 12.079

3.  Postoperative complications in the Tube Versus Trabeculectomy (TVT) study during five years of follow-up.

Authors:  Steven J Gedde; Leon W Herndon; James D Brandt; Donald L Budenz; William J Feuer; Joyce C Schiffman
Journal:  Am J Ophthalmol       Date:  2012-01-14       Impact factor: 5.258

4.  Trabecular microbypass stents as minimally invasive approach after conventional glaucoma filtration surgery.

Authors:  Thomas Macher; Heike Häberle; Juliane Wächter; Carsten Thannhäuser; Henning Aurich; Duy-Thoai Pham
Journal:  J Cataract Refract Surg       Date:  2018-01       Impact factor: 3.351

5.  Manchester iStent study: early results from a prospective UK case series.

Authors:  Ilesh Patel; Timothy A de Klerk; Leon Au
Journal:  Clin Exp Ophthalmol       Date:  2013-04-11       Impact factor: 4.207

6.  Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma.

Authors:  Detlev Spiegel; Wolfgang Wetzel; David S Haffner; Richard A Hill
Journal:  Adv Ther       Date:  2007 Jan-Feb       Impact factor: 3.845

7.  Prospective, unmasked evaluation of the iStent® inject system for open-angle glaucoma: synergy trial.

Authors:  Lilit Voskanyan; Julián García-Feijoó; Jose I Belda; Antonio Fea; Anselm Jünemann; Christophe Baudouin
Journal:  Adv Ther       Date:  2014-01-23       Impact factor: 3.845

8.  Intermediate Results of iStent or iStent inject Implantation Combined with Cataract Surgery in a Real-World Setting: A Longitudinal Retrospective Study.

Authors:  Ricardo Augusto Paletta Guedes; Daniela Marcelo Gravina; Jonathan Clive Lake; Vanessa Maria Paletta Guedes; Alfredo Chaoubah
Journal:  Ophthalmol Ther       Date:  2019-02-05

9.  Second-Generation Trabecular Micro-Bypass Stents as Standalone Treatment for Glaucoma: A 36-Month Prospective Study.

Authors:  Fritz H Hengerer; Gerd U Auffarth; Christoffer Riffel; Ina Conrad-Hengerer
Journal:  Adv Ther       Date:  2019-05-22       Impact factor: 3.845

10.  Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery.

Authors:  David Manning
Journal:  Ophthalmol Ther       Date:  2019-08-17
View more
  1 in total

1.  Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension.

Authors:  Colin Clement; Frank Howes; Alexandros Ioannidis; Michael Shiu; David Manning; Jed A Lusthaus; Simon E Skalicky; Todd W Goodwin
Journal:  Clin Ophthalmol       Date:  2022-09-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.