Literature DB >> 3441833

Response variability of somatosensory evoked potentials during scoliosis surgery.

D H York1, R J Chabot, R W Gaines.   

Abstract

Somatosensory evoked potentials (SSEP) were recorded from the scalp for intraoperative monitoring of patients undergoing surgical correction of spine deformities or spine fractures. Alterations in the SSEP with distraction, spine manipulation, anesthesia, hypotension, and other intraoperative variables are described. When loss of the SSEP occurred and a waiting period was undertaken until it returned, all patients with an SSEP present upon closing, which was within +/- 2 SD of their anesthetized control values, had no neurologic complications. Alterations in SSEP consisting of increases in latency of 15% and decreases in amplitude of 50% were not associated with any postoperative neurologic deficits.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3441833     DOI: 10.1097/00007632-198711000-00007

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

1.  Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring.

Authors:  J Richard Toleikis
Journal:  J Clin Monit Comput       Date:  2005-06       Impact factor: 2.502

2.  Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.

Authors:  Samyuktha R Melachuri; Jeffrey R Balzer; Manasa K Melachuri; David Ninaci; Katherine Anetakis; Jaspreet Kaur; Donald J Crammond; Parthasarathy D Thirumala
Journal:  J Clin Monit Comput       Date:  2018-05-31       Impact factor: 2.502

3.  Somatosensory evoked potential. Monitoring during spinal surgery.

Authors:  M T Stechison; S G Panagis; S S Reinhart
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

Review 4.  Somatosensory evoked potential loss due to intraoperative pulse lavage during spine surgery: case report and review of signal change management.

Authors:  Arun George; Hironobu Hayashi; John F Bebawy; Antoun Koht
Journal:  J Clin Monit Comput       Date:  2019-03-05       Impact factor: 2.502

5.  Predictive Value of Somatosensory Evoked Potential Monitoring during Resection of Intraparenchymal and Intraventricular Tumors Using an Endoscopic Port.

Authors:  Parthasarathy Thirumala; Daniel Lai; Jonathan Engh; Miguel Habeych; Donald Crammond; Jeffrey Balzer
Journal:  J Clin Neurol       Date:  2013-10-31       Impact factor: 3.077

6.  Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint.

Authors:  Michael Woods; Denise Birkholz; Regina MacBarb; Robyn Capobianco; Adam Woods
Journal:  Adv Orthop       Date:  2014-12-04

7.  Transcranial Motor Evoked Potentials during Spinal Deformity Corrections-Safety, Efficacy, Limitations, and the Role of a Checklist.

Authors:  Shankar Acharya; Nagendra Palukuri; Pravin Gupta; Manish Kohli
Journal:  Front Surg       Date:  2017-02-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.