Jihee Kim1, Stuart K Gardiner2, Andrea Ramazzotti3, Udayakumar Karuppanan3, Luigi Bruno4, Christopher A Girkin3, J Crawford Downs3, Massimo A Fazio5. 1. Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA. 2. Devers Eye Institute, Legacy Health, Portland, OR, USA. 3. Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA. 4. Department of Mechanical, Energy and Management Engineering, University of Calabria, Rende, CS, Italy. 5. Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA; Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA; The Viterbi Family Department of Ophthalmology, UC San Diego, La Jolla, CA, USA. Electronic address: massimofazio@uabmc.edu.
Abstract
PURPOSE: To determine if in vivo strain response of the Optic Nerve Head (ONH) to IOP elevation visualized using Optical Coherence Tomography (OCT) video imaging and quantified using novel virtual extensometers was able to be provided repeatable measurements of tissue specific deformations. METHODS: The ONHs of 5 eyes from 5 non-human primates (NHPs) were imaged by Spectralis OCT. A vertical and a horizontal B-scan of the ONH were continuously recorded for 60 s at 6 Hz (video imaging mode) during IOP elevation from 10 to 30 mmHg. Imaging was repeated over three imaging sessions. The 2D normal strain was computed by template-matching digital image correlation using virtual extensometers. ANOVA F-test (F) was used to compare inter-eye, inter-session, and inter-tissue variability for the prelaminar, Bruch's membrane opening (BMO), lamina cribrosa (LC) and choroidal regions (against variance the error term). F-test of the ratio between inter-eye to inter-session variability was used to test for strain repeatability across imaging sessions (FIS). RESULTS: Variability of strain across imaging session (F = 0.7263, p = 0.4855) and scan orientation was not significant (F = 1.053, p = 0.3066). Inter session variability of strain was significantly lower than inter-eye variability (FIS = 22.63, p = 0.0428) and inter-tissue variability (FIS = 99.33 p = 0.00998). After IOP elevation, strain was highest in the choroid (-18.11%, p < 0.001), followed by prelaminar tissue (-11.0%, p < 0.001), LC (-3.79%, p < 0.001), and relative change in BMO diameter (-0.57%, p = 0.704). CONCLUSIONS: Virtual extensometers applied to video-OCT were sensitive to the eye-specific and tissue-specific mechanical response of the ONH to IOP and were repeatable across imaging sessions.
PURPOSE: To determine if in vivo strain response of the Optic Nerve Head (ONH) to IOP elevation visualized using Optical Coherence Tomography (OCT) video imaging and quantified using novel virtual extensometers was able to be provided repeatable measurements of tissue specific deformations. METHODS: The ONHs of 5 eyes from 5 non-human primates (NHPs) were imaged by Spectralis OCT. A vertical and a horizontal B-scan of the ONH were continuously recorded for 60 s at 6 Hz (video imaging mode) during IOP elevation from 10 to 30 mmHg. Imaging was repeated over three imaging sessions. The 2D normal strain was computed by template-matching digital image correlation using virtual extensometers. ANOVA F-test (F) was used to compare inter-eye, inter-session, and inter-tissue variability for the prelaminar, Bruch's membrane opening (BMO), lamina cribrosa (LC) and choroidal regions (against variance the error term). F-test of the ratio between inter-eye to inter-session variability was used to test for strain repeatability across imaging sessions (FIS). RESULTS: Variability of strain across imaging session (F = 0.7263, p = 0.4855) and scan orientation was not significant (F = 1.053, p = 0.3066). Inter session variability of strain was significantly lower than inter-eye variability (FIS = 22.63, p = 0.0428) and inter-tissue variability (FIS = 99.33 p = 0.00998). After IOP elevation, strain was highest in the choroid (-18.11%, p < 0.001), followed by prelaminar tissue (-11.0%, p < 0.001), LC (-3.79%, p < 0.001), and relative change in BMO diameter (-0.57%, p = 0.704). CONCLUSIONS: Virtual extensometers applied to video-OCT were sensitive to the eye-specific and tissue-specific mechanical response of the ONH to IOP and were repeatable across imaging sessions.
Authors: Claude F Burgoyne; J Crawford Downs; Anthony J Bellezza; J-K Francis Suh; Richard T Hart Journal: Prog Retin Eye Res Date: 2005-01 Impact factor: 21.198
Authors: J Crawford Downs; Claude F Burgoyne; William P Seigfreid; Juan F Reynaud; Nicholas G Strouthidis; Verney Sallee Journal: Invest Ophthalmol Vis Sci Date: 2011-09-21 Impact factor: 4.799
Authors: Jean Martial Mari; Nicholas G Strouthidis; Sung Chul Park; Michaël J A Girard Journal: Invest Ophthalmol Vis Sci Date: 2013-03-01 Impact factor: 4.799
Authors: Rafael Grytz; Massimo A Fazio; Vincent Libertiaux; Luigi Bruno; Stuart Gardiner; Christopher A Girkin; J Crawford Downs Journal: Invest Ophthalmol Vis Sci Date: 2014-11-11 Impact factor: 4.799
Authors: Meghna R Beotra; Xiaofei Wang; Tin A Tun; Liang Zhang; Mani Baskaran; Tin Aung; Nicholas G Strouthidis; Michaël J A Girard Journal: Invest Ophthalmol Vis Sci Date: 2018-01-01 Impact factor: 4.799