Time-domain signal averaging to improve microparticles detection and enumeration accuracy in a microfluidic impedance cytometer.

Brandon K Ashley1, Umer Hassan1,2,3.   

Abstract

Microfluidic impedance cytometry is a powerful system to measure micro and nano-sized particles and is routinely used in point-of-care disease diagnostics and other biomedical applications. However, small objects near a sensor's detection limit are plagued with relatively significant background noise and are difficult to identify for every case. While many data processing techniques can be utilized to reduce noise and improve signal quality, frequently they are still inadequate to push sensor detection limits. Here, we report the first demonstration of a novel signal averaging algorithm effective in noise reduction of microfluidic impedance cytometry data, improving enumeration accuracy, and reducing detection limits. Our device uses a 22 µm tall × 100 µm wide (with 30 µm wide focused aperture) microchannel and gold coplanar microelectrodes that generate an electric field, recording bipolar pulses from polystyrene microparticles flowing through the channel. In addition to outlining a modified moving signal averaging technique theoretically and with a model data set, we also performed a compendium of characterization experiments including variations in flow rate, input voltage, and particle size. Multivariate metrics from each experiment are compared including signal amplitude, pulse width, background noise, and signal-to-noise ratio (SNR). Incorporating our technique resulted in improved SNR and counting accuracy across all experiments conducted, and the limit of detection improved from 5 to 1 µm particles without modifying microchannel dimensions. Succeeding this, we envision implementing our modified moving average technique to develop next-generation microfluidic impedance cytometry devices with an expanded dynamic range and improved enumeration accuracy. This can be exceedingly useful for many biomedical applications, such as infectious disease diagnostics where devices may enumerate larger-scale immune cells alongside sub-micron bacterium in the same sample.
© 2021 Wiley Periodicals LLC.

Entities:  

Keywords:  disease diagnostics; microfluidics; point-of-care; signal processing

Mesh:

Year:  2021        PMID: 34370302      PMCID: PMC8589102          DOI: 10.1002/bit.27910

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  35 in total

Review 1.  Nocturnal monitoring of home non-invasive ventilation: the contribution of simple tools such as pulse oximetry, capnography, built-in ventilator software and autonomic markers of sleep fragmentation.

Authors:  Jean-Paul Janssens; Jean-Christian Borel; Jean-Louis Pépin
Journal:  Thorax       Date:  2010-10-22       Impact factor: 9.139

2.  Label-Free Impedance Biosensors: Opportunities and Challenges.

Authors:  Jonathan S Daniels; Nader Pourmand
Journal:  Electroanalysis       Date:  2007-05-16       Impact factor: 3.223

3.  Signal quality measures for pulse oximetry through waveform morphology analysis.

Authors:  J Abdul Sukor; S J Redmond; N H Lovell
Journal:  Physiol Meas       Date:  2011-02-18       Impact factor: 2.833

Review 4.  Clogging of microfluidic systems.

Authors:  Emilie Dressaire; Alban Sauret
Journal:  Soft Matter       Date:  2016-12-21       Impact factor: 3.679

5.  High-throughput impedance spectroscopy biosensor array chip.

Authors:  Xiaowen Liu; Lin Li; Andrew J Mason
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-02-24       Impact factor: 4.226

6.  A Low-Cost Smartphone-Based Electrochemical Biosensor for Point-of-Care Diagnostics.

Authors:  Alexander Sun; Travis Wambach; A G Venkatesh; Drew A Hall
Journal:  IEEE Biomed Circuits Syst Conf       Date:  2014-10

Review 7.  Point-of-critical-care diagnostics for sepsis enabled by multiplexed micro and nanosensing technologies.

Authors:  Brandon K Ashley; Umer Hassan
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2021-03-01

8.  Self-Powered Portable Electronic Reader for Point-of-Care Amperometric Measurements.

Authors:  Yaiza Montes-Cebrián; Albert Álvarez-Carulla; Jordi Colomer-Farrarons; Manel Puig-Vidal; Pere Ll Miribel-Català
Journal:  Sensors (Basel)       Date:  2019-08-27       Impact factor: 3.576

9.  Design of a Multiplexed Analyte Biosensor using Digital Barcoded Particles and Impedance Spectroscopy.

Authors:  Shreya Prakash; Brandon K Ashley; Patrick S Doyle; Umer Hassan
Journal:  Sci Rep       Date:  2020-04-09       Impact factor: 4.379

10.  Signal averaging improves signal-to-noise in OCT images: But which approach works best, and when?

Authors:  Bernhard Baumann; Conrad W Merkle; Rainer A Leitgeb; Marco Augustin; Andreas Wartak; Michael Pircher; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2019-10-17       Impact factor: 3.732

View more
  2 in total

1.  Antibody-functionalized aluminum oxide-coated particles targeting neutrophil receptors in a multifrequency microfluidic impedance cytometer.

Authors:  Brandon K Ashley; Jianye Sui; Mehdi Javanmard; Umer Hassan
Journal:  Lab Chip       Date:  2022-08-09       Impact factor: 7.517

2.  Aluminum Oxide-Coated Particle Differentiation Employing Supervised Machine Learning and Impedance Cytometry.

Authors:  Brandon K Ashley; Jianye Sui; Mehdi Javanmard; Umer Hassan
Journal:  IEEE Int Conf Nano Micro Eng Mol Syst       Date:  2022-06-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.