OBJECTIVES: To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM).Entities:
Keywords: 3D mammography; Breast cancer; Digital breast tomosynthesis; Mammography
Mesh:
Year: 2021 PMID: 34324025 PMCID: PMC8660729 DOI: 10.1007/s00330-021-08079-2
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315
Histology and lesion type of the lesions included in the analysis
| Histology | Number of lesions (%) |
|---|---|
| Malignant | 89 (49.7) |
| Invasive carcinoma NST | 43 (48.3) |
| Invasive carcinoma NST with DCIS | 29 (32.6) |
| Invasive lobular carcinoma | 3 (3.4) |
| Invasive lobular carcinoma with DCIS | 2 (2.2) |
| Ductal carcinoma in situ | 11 (12.4) |
| Angiosarcoma | 1 (1.1) |
| Benign | 90 (50.3) |
| Fibrocystic changes | 38 (42.2) |
| Fibroadenoma | 21 (23.4) |
| Papilloma | 17 (18.9) |
| Adenosis | 4 (4.4) |
| Other | 10 (11.1) |
| Lesion type | 179 (100) |
| Mass | 87 (48.6) |
| Microcalcifications | 65 (36.3) |
| Architectural distortion | 19 (10.6) |
| Asymmetry | 8 (4.5) |
NST non-special type, DCIS ductal carcinoma in situ, Other periductal mastitis, pseudoangiomatous stromal hyperplasia, hamartoma, inflammation
Lesion detection rate for each reader for the three reading protocols: two-view digital mammography (2v-DM), one-view wide-angle digital breast tomosynthesis with synthetic mammography (1v-WA-DBT/SM), and two-view WA-DBT with SM (2v-WA-DBT/SM)
| 2v-DM | 1v-WA-DBT/SM | 2v-WA-DBT/SM | |
|---|---|---|---|
| Detection | |||
| Reader 1 | 138 (77.1) | 135 (75.4) | 139 (77.7) |
| Reader 2 | 123 (68.7) | 120 (67.0) | 131 (73.2)* |
| Reader 3 | 136 (76.0) | 138 (77.1) | 140 (78.2) |
| Reader 4 | 143 (79.9) | 144 (80.4) | 152 (84.9)* |
N° number of lesions detected of the total of 179 lesions included in the analysis
*Significant difference compared to 2v-DM
Distribution of the ACR BI-RADS categories in the detected lesions per reader and reading protocols (two-view digital mammography (2v-DM), one-view wide-angle digital breast tomosynthesis with synthetic mammography (1v-WA-DBT/SM), and two-view WA-DBT with SM (2v-WA-DBT/SM))
| Reading protocol | Reader | BI-RADS 2 | BI-RADS 3 | BI-RADS 4 | BI-RADS 5 |
|---|---|---|---|---|---|
| 2v-DM | 1 | 40 | 9 | 53 | 36 |
| 2 | 28 | 9 | 44 | 42 | |
| 3 | 32 | 21 | 50 | 33 | |
| 4 | 48 | 17 | 44 | 34 | |
| 1v-WA-DBT/SM | 1 | 40 | 17 | 40 | 38 |
| 2 | 24 | 7 | 24 | 65 | |
| 3 | 25 | 28 | 37 | 48 | |
| 4 | 37 | 20 | 43 | 44 | |
| 2v-WA-DBT/SM | 1 | 43 | 11 | 43 | 42 |
| 2 | 27 | 7 | 27 | 70 | |
| 3 | 31 | 22 | 34 | 53 | |
| 4 | 41 | 14 | 46 | 51 |
Diagnostic performance for each reader for the three reading protocols: two-view digital mammography (2v-DM), one-view wide-angle digital breast tomosynthesis with synthetic mammography (1v-WA-DBT/SM), and two-view WA-DBT with SM (2v-WA-DBT/SM)
| 2v-DM | 1v-WA-DBT/SM | 2v-WA-DBT/SM | |
|---|---|---|---|
| Sensitivity | |||
| Reader 1 | 77.5 (69/89) | 76.4 (68/89) | 79.8 (71/89) |
| Reader 2 | 71.9 (64/89) | 82.0 (73/89) | 85.4* (76/89) |
| Reader 3 | 73.0 (65/89) | 80.9 (72/89) | 82.0 (73/89) |
| Reader 4 | 67.4 (60/89) | 79.8 (71/89) | 85.4* (76/89) |
| Specificity | |||
| Reader 1 | 63.5 (40/63) | 78.3 (47/60) | 74.2 (46/62) |
| Reader 2 | 46.3 (25/54) | 60.0 (27/45) | 53.7 (29/54) |
| Reader 3 | 63.5 (40/63) | 64.9 (37/57) | 72.6 (45/62) |
| Reader 4 | 65.6 (42/64) | 72.3 (47/65) | 68.6 (48/70) |
| Accuracy | |||
| Reader 1 | 71.7 (109/152) | 77.2 (115/149) | 77.5 (117/151) |
| Reader 2 | 62.2 (89/143) | 74.6* (100/134) | 73.4* (105/143) |
| Reader 3 | 69.1 (105/152) | 74.7 (109/146) | 78.1 (118/151) |
| Reader 4 | 66.7 (102/153) | 76.6 (118/154) | 78.0* (124/159) |
*Significant difference compared to 2v-DM
Fig. 1A 56-year-old woman with suspicious calcifications on the right side (benign at biopsy). An architectural distortion was visible in the upper outer quadrant of the left breast (arrow). The lesion was detected and correctly classified as suspicious by one in four readers with digital mammography (DM) and with one-view wide-angle digital breast tomosynthesis with synthetic mammography (WA-DBT with SM), while it was detected and classified as suspicious by three in four readers with two-view WA-DBT with SM. The lesion was biopsied under ultrasound guidance, and the diagnosis was invasive ductal carcinoma grade 2 with ductal carcinoma in situ (a, b DM bilateral mediolateral oblique view (MLO); c SM MLO; d DBT MLO; e, f DM bilateral cranio-caudal view (CC); g SM CC; h DBT CC)
Fig. 2A 51-year-old woman with extremely dense breasts. An architectural distortion was visible in the upper quadrant of the left breast (circle). The lesion was detected and classified as probably benign on digital mammography (DM) by one in four readers and suspicious by the other three readers. All four readers agreed in identifying the lesion as suspicious when evaluating one-view wide-angle digital breast tomosynthesis with synthetic mammography (WA-DBT with SM) and two-view WA-DBT with SM. The lesion was biopsied under ultrasound guidance and the diagnosis was fibrotic breast tissue with multiple papillomas. The absence of malignancy was confirmed at surgery. (a, b DM bilateral mediolateral oblique view (MLO); c SM MLO; d DBT MLO; e, f DM bilateral cranio-caudal view (CC); g SM CC; h DBT CC)
Average accuracy of the three reading protocols for different breast densities, classified as according to the American College of Radiology (ACR) BI-RADS lexicon, and different lesion types
| Accuracy | 2v-DM % (95% CI) | 1v-WA-DBT/SM % (95% CI) | 2v-WA-DBT/SM % (95% CI) |
|---|---|---|---|
| ACR a | 83.3 (71.1–91.1) | 83.5 (70.0–91.7) | 88.8 (76.2–95.1) |
| ACR b | 79.3 (69.7–86.5) | 84.1 (75.1–90.3) | 87.5 (79.6–92.6) |
| ACR c | 72.8 (64.7–79.6) | 84.4 (77.1–89.6) | 81.5 (74.9–86.7) |
| ACR d | 60.6(44.9–74.4) | 69.0(55.9–79.7) | 66.7(50.8–79.5) |
| Mass | 83.7 (77.3–88.6) | 86.8 (80.6–91.2) | 90.8 (85.5–94.3) |
| Microcalcifications | 65.5 (53.8–75.5) | 78.9 (68.1–86.7) | 74.7 (63.3–83.5) |
| Architectural distortion | 64.1 (39.9–82.8) | 71.3 (42.7–89.2) | 56.9 (36.5–75.2) |
| Asymmetry | 40.7 (13.8–74.6) | 61.0 (25.1–88.0) | 72.5 (43.7–89.9) |
2v-DM two-view digital mammography, 1v-WA-DBT/SM one-view wide-angle digital breast tomosynthesis with synthetic mammography, 2v-WA-DBT/SM two-view wide-angle digital breast tomosynthesis with synthetic mammography