Literature DB >> 34313320

Percutaneous venopulmonary artery extracorporeal membrane oxygenation for right heart failure after left ventricular assist device insertion.

Yashutosh Joshi1,2,3, Marie-Cecile Bories4, Nadia Aissaoui5,6, Jean-Michel Grinda4, Alain Bel4, Christian Latremouille4,6, Jérôme Jouan4,6.   

Abstract

OBJECTIVES: Right ventricular failure after left ventricular assist device (LVAD) insertion is associated with significant mortality and morbidity. Mechanical support options include right ventricular assist devices, venoarterial extracorporeal membrane oxygenation (ECMO) and venopulmonary artery ECMO, the latter often involving central cannulation. We sought to evaluate the feasibility and early outcomes of a truly percutaneous venopulmonary artery (pVPA) ECMO strategy, with the potential advantage of bedside removal once weaned.
METHODS: Data from a single tertiary centre were reviewed retrospectively from January 2014 to January 2019. During this time, 54 patients underwent LVAD insertion, with 19 requiring mechanical support for right ventricular failure. Among them, 10 patients received pVPA ECMO. Implantation of the pVPA ECMO was performed under transoesophageal echocardiography and fluoroscopy guidance, with an inflow cannula placed in the right atrium via the right femoral vein and an outflow cannula placed in the left pulmonary artery (PA) via the right internal jugular vein.
RESULTS: Cannula insertion was 100% successful with no need for repositioning. Eight patients (80%) were able to be successfully weaned (at the bedside); 6 were discharged from the hospital and there were no cases of early sepsis, mediastinitis or thromboembolism. At follow-up, 5 patients had received transplants (50%), with 1 on LVAD support as destination therapy (10%). Survival was 60 ± 15% and 50 ± 16% at 6 and 12 months, respectively.
CONCLUSIONS: pVPA ECMO is 100% technically feasible and is an efficient method for temporary right ventricular support after LVAD insertion with the advantage of simple bedside removal and avoidance of a PA graft remnant in the chest cavity.
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Extracorporeal membrane oxygenation; Left ventricular assist device; Mechanical support; Right ventricular failure

Mesh:

Year:  2021        PMID: 34313320      PMCID: PMC8923379          DOI: 10.1093/icvts/ivab197

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  26 in total

1.  Extracorporeal membrane oxygenation as perioperative right ventricular support in patients with biventricular failure undergoing left ventricular assist device implantation.

Authors:  Mirela Scherer; Abdul Sami Sirat; Anton Moritz; Sven Martens
Journal:  Eur J Cardiothorac Surg       Date:  2010-11-10       Impact factor: 4.191

2.  Benefits of a novel percutaneous ventricular assist device for right heart failure: The prospective RECOVER RIGHT study of the Impella RP device.

Authors:  Mark B Anderson; James Goldstein; Carmelo Milano; Lynn D Morris; Robert L Kormos; Jay Bhama; Navin K Kapur; Aditya Bansal; Jose Garcia; Joshua N Baker; Scott Silvestry; William L Holman; Pamela S Douglas; William O'Neill
Journal:  J Heart Lung Transplant       Date:  2015-09-08       Impact factor: 10.247

3.  Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure.

Authors:  Nicholas C Dang; Veli K Topkara; Michelle Mercando; Joy Kay; Kurt H Kruger; Michael S Aboodi; Mehmet C Oz; Yoshifumi Naka
Journal:  J Heart Lung Transplant       Date:  2005-12-09       Impact factor: 10.247

4.  Risk factors predictive of right ventricular failure after left ventricular assist device implantation.

Authors:  Stavros G Drakos; Lindsay Janicki; Benjamin D Horne; Abdallah G Kfoury; Bruce B Reid; Stephen Clayson; Kenneth Horton; Francois Haddad; Dean Y Li; Dale G Renlund; Patrick W Fisher
Journal:  Am J Cardiol       Date:  2010-02-13       Impact factor: 2.778

5.  Temporary percutaneous right ventricular support using a centrifugal pump in patients with postoperative acute refractory right ventricular failure after left ventricular assist device implantation.

Authors:  Assad Haneya; Alois Philipp; Thomas Puehler; Leopold Rupprecht; Reinhard Kobuch; Michael Hilker; Christof Schmid; Stephan W Hirt
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

6.  Alternative right ventricular assist device implantation technique for patients with perioperative right ventricular failure.

Authors:  Diyar Saeed; Bujar Maxhera; Hiroyuki Kamiya; Artur Lichtenberg; Alexander Albert
Journal:  J Thorac Cardiovasc Surg       Date:  2014-11-01       Impact factor: 5.209

Review 7.  Postoperative acute refractory right ventricular failure: incidence, pathogenesis, management and prognosis.

Authors:  T K Kaul; B L Fields
Journal:  Cardiovasc Surg       Date:  2000-01

8.  The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates.

Authors:  Jennifer Cowger Matthews; Todd M Koelling; Francis D Pagani; Keith D Aaronson
Journal:  J Am Coll Cardiol       Date:  2008-06-03       Impact factor: 24.094

9.  Timing of temporary right ventricular assist device insertion for severe right heart failure after left ventricular assist device implantation.

Authors:  Koji Takeda; Yoshifumi Naka; Jonathan A Yang; Nir Uriel; Paolo C Colombo; Ulrich P Jorde; Hiroo Takayama
Journal:  ASAIO J       Date:  2013 Nov-Dec       Impact factor: 2.872

10.  Pulmonary artery cannulation to enhance extracorporeal membrane oxygenation management in acute cardiac failure.

Authors:  Roberto Lorusso; Giuseppe Maria Raffa; Samuel Heuts; Valeria Lo Coco; Paolo Meani; Ehsan Natour; Elham Bidar; Thijs Delnoij; Antonio Loforte
Journal:  Interact Cardiovasc Thorac Surg       Date:  2020-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.