Literature DB >> 34308708

Acoustic Ejection Mass Spectrometry: A Fully Automatable Technology for High-Throughput Screening in Drug Discovery.

Roman P Simon1, Tim T Häbe1, Robert Ries1, Martin Winter1, Yuting Wang1, Amaury Fernández-Montalván1, Daniel Bischoff1, Frank Runge1, Wolfgang Reindl1, Andreas H Luippold1, Frank H Büttner1.   

Abstract

Acoustic droplet ejection (ADE)-open port interface (OPI)-mass spectrometry (MS) has recently been introduced as a versatile analytical method that combines fast and contactless acoustic sampling with sensitive and accurate electrospray ionization (ESI)-MS-based analyte detection. The potential of the technology to provide label-free measurements in subsecond analytical cycle times makes it an attractive option for high-throughput screening (HTS). Here, we report the first implementation of ADE-OPI-MS in a fully automated HTS environment, based on the example of a biochemical assay aiming at the identification of small-molecule inhibitors of the cyclic guanosine monophosphate-adenosine monophosphate (GMP-AMP) synthase (cGAS). First, we describe the optimization of the method to enable sensitive and accurate determination of enzyme activity and inhibition in miniaturized 1536-well microtiter plate format. Then we show both results from a validation single-concentration screen using a test set of 5500 compounds, and the subsequent concentration-response testing of selected hits in direct comparison with a previously established matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) readout. Finally, we present the development of an in-line OPI cleaning procedure aiming to match the instrument robustness required for large-scale HTS campaigns. Overall, this work points to critical method development parameters and provides guidance for the establishment of integrated ADE-OPI-MS as HTS-compatible technology for early drug discovery.

Entities:  

Keywords:  acoustic ejection mass spectrometry; cGAS; high-throughput; label-free screening; open port interface

Mesh:

Year:  2021        PMID: 34308708     DOI: 10.1177/24725552211028135

Source DB:  PubMed          Journal:  SLAS Discov        ISSN: 2472-5552            Impact factor:   3.341


  1 in total

1.  Ultrahigh-Throughput Sample Analysis Using Liquid Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

Authors:  Henriette Krenkel; Jeffery Brown; Keith Richardson; Emmy Hoyes; Michael Morris; Rainer Cramer
Journal:  Anal Chem       Date:  2022-03-02       Impact factor: 8.008

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.