Literature DB >> 34308586

[The safety of TiRobot-guided percutaneous transpedicular screw implantation].

Shu Lin1, Jiang Hu1, Lun Wan1, Liuyi Tang1, Yue Wang1, Yang Yu1, Wei Zhang1.   

Abstract

OBJECTIVE: To evaluate the safety of TiRobot-guided percutaneous transpedicular screw implantation.
METHODS: The medical records of 158 patients with thoracolumbar fractures and lumbar degenerative diseases who underwent percutaneous transpedicular screw implantation were retrospectively analyzed between January 2018 and December 2020. The patients were divided into trial group (TiRobot-guided screw implantation, 86 cases) and control group (fluoroscopy-guided screw implantation, 72 cases). There was no significant difference in gender, age, pathology, lesion segment, and the average number of screw implantation per case ( P>0.05). The operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency were compared between the two groups. One day postoperatively, the convergence angle was measured and the penetration of the pedicle cortex was evaluated according to Gertzbein-Robbins classification standard.
RESULTS: The operation time, fluoroscopic dose, fluoroscopic time, and fluoroscopic frequency of the trial group were significantly lesser than those of control group ( P<0.05). One day postoperatively, the convergence angle of trial group was (21.10±4.08)°, which was significantly larger than control group (19.17±3.48)° ( t=6.810, P=0.000). According to the Gertzbein-Robbins classification standard, 446 pedicle screws were implanted in trial group, trajectories were grade A in 377 screws, grade B in 46 screws, grade C in 23 screws, and the accuracy of screw implantation was 94.8%; 380 pedicle screws were implanted in control group, trajectories were grade A in 283 screws, grade B in 45 screws, grade C in 44 screws, grade D in 6 screws, grade E in 2 screws, and the accuracy of screw implantation was 86.3%. There was significant difference in the accuracy of screw implantation between the two groups ( χ 2=25.950, P=0.000).
CONCLUSION: Compared with traditional percutaneous transpedicular screw implantation, TiRobot-guided percutaneous transpedicular screw implantation can improve the accuracy of screw implantation, reduce radiation exposure, and improve surgical safety, which has a good application prospect.

Entities:  

Keywords:  Robot; lumbar degenerative disease; percutaneous screw implantation; safety; thoracolumbar fracture

Mesh:

Year:  2021        PMID: 34308586      PMCID: PMC8311213          DOI: 10.7507/1002-1892.202103072

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  20 in total

1.  Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy.

Authors:  Constantin Schizas; Eric Thein; Barbara Kwiatkowski; Gerit Kulik
Journal:  Acta Orthop Belg       Date:  2012-04       Impact factor: 0.500

2.  Unskilled unawareness and the learning curve in robotic spine surgery.

Authors:  Bawarjan Schatlo; Ramon Martinez; Awad Alaid; Kajetan von Eckardstein; Reza Akhavan-Sigari; Anina Hahn; Florian Stockhammer; Veit Rohde
Journal:  Acta Neurochir (Wien)       Date:  2015-08-19       Impact factor: 2.216

3.  Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions: A Randomized Controlled Trial.

Authors:  Seung-Jae Hyun; Ki-Jeong Kim; Tae-Ahn Jahng; Hyun-Jib Kim
Journal:  Spine (Phila Pa 1976)       Date:  2017-03-15       Impact factor: 3.468

4.  Evaluation of surgical strategy of conventional vs. percutaneous robot-assisted spinal trans-pedicular instrumentation in spondylodiscitis.

Authors:  Naureen Keric; David J Eum; Feroz Afghanyar; Izabela Rachwal-Czyzewicz; Mirjam Renovanz; Jens Conrad; Dominik M A Wesp; Sven R Kantelhardt; Alf Giese
Journal:  J Robot Surg       Date:  2016-06-09

5.  Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.

Authors:  Volodymyr Solomiichuk; Julius Fleischhammer; Granit Molliqaj; Jwad Warda; Awad Alaid; Kajetan von Eckardstein; Karl Schaller; Enrico Tessitore; Veit Rohde; Bawarjan Schatlo
Journal:  Neurosurg Focus       Date:  2017-05       Impact factor: 4.047

6.  Spinal robotics: current applications and future perspectives.

Authors:  Florian Roser; Marcos Tatagiba; Gottlieb Maier
Journal:  Neurosurgery       Date:  2013-01       Impact factor: 4.654

7.  Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist.

Authors:  W Sukovich; S Brink-Danan; M Hardenbrook
Journal:  Int J Med Robot       Date:  2006-06       Impact factor: 2.547

8.  Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population.

Authors:  Jeremy J Macke; Raymund Woo; Laura Varich
Journal:  J Robot Surg       Date:  2016-04-12

9.  Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement.

Authors:  Sven Rainer Kantelhardt; Ramon Martinez; Stefan Baerwinkel; Ralf Burger; Alf Giese; Veit Rohde
Journal:  Eur Spine J       Date:  2011-03-08       Impact factor: 3.134

10.  Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study.

Authors:  Jun-Song Yang; Baorong He; Fang Tian; Tuan-Jiang Liu; Peng Liu; Jia-Nan Zhang; Shi-Chang Liu; Yuan Tuo; Lei Chu; Ding-Jun Hao
Journal:  Med Sci Monit       Date:  2019-04-04
View more
  2 in total

1.  [TiRobot-assisted surgery by O-arm navigation system for percutaneous minimally invasive treatment of posterior pelvic ring injury].

Authors:  Shuo Ge; Lei Zhang; Zifei Zhou; Shaohua Jia; Longpo Zheng
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-08-15

2.  [Preliminary application study of dual-robotic navigated minimally invasive treatment by TiRobot and Artis Zeego on pelvic fractures].

Authors:  Kexin Liu; Mengzhen You; Moran Huang; Cheng Chen; Biyu Rui; Hong Gao; Yunfeng Chen; Xiaolin Li; Wei Zhang; Yuqiang Sun; Lei Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-08-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.