Literature DB >> 34299146

Development of Polypyrrole Modified Screen-Printed Carbon Electrode Based Sensors for Determination of L-Tyrosine in Pharmaceutical Products.

Ancuța Dinu1, Constantin Apetrei1.   

Abstract

Good health, of vital importance in order to carry out our daily routine, consists of both physical and mental health. Tyrosine (Tyr) deficiency as well as its excess are issues that can affect mental health and can generate disorders such as depression, anxiety, or stress. Tyr is the amino acid (AA) responsible for maintaining good mental health, and for this reason, the present research presents the development of new electrochemical sensors modified with polypyrrole (PPy) doped with different doping agents such as potassium hexacyanoferrate (II) (FeCN), sodium nitroprusside (NP), and sodium dodecyl sulfate (SDS) for a selective and sensitive detection of Tyr. The development of the sensors was carried out by chronoamperometry (CA) and the electrochemical characterization was carried out by cyclic voltammetry (CV). The detection limits (LOD) obtained with each modified sensor were 8.2 × 10-8 M in the case of PPy /FeCN-SPCE, 4.3 × 10-7 M in the case of PPy/NP-SPCE, and of 3.51 × 10-7 M in the case of PPy/SDS-SPCE, thus demonstrating a good sensitivity of these sensors detecting L-Tyr. The validation of sensors was carried out through quantification of L-Tyr from three pharmaceutical products by the standard addition method with recoveries in the range 99.92-103.97%. Thus, the sensors present adequate selectivity and can be used in the pharmaceutical and medical fields.

Entities:  

Keywords:  L-Tyrosine; amino acid; chronoamperometry; cyclic voltammetry; polypyrrole; sensor

Year:  2021        PMID: 34299146     DOI: 10.3390/ijms22147528

Source DB:  PubMed          Journal:  Int J Mol Sci        ISSN: 1422-0067            Impact factor:   5.923


  3 in total

1.  Electrochemical L-Tyrosine Sensor Based on a Glassy Carbon Electrode Modified with Exfoliated Graphene.

Authors:  Codruţa Varodi; Florina Pogăcean; Maria Coroş; Alexandra Ciorîță; Stela Pruneanu
Journal:  Sensors (Basel)       Date:  2022-05-10       Impact factor: 3.847

2.  Quantification of Tyrosine in Pharmaceuticals with the New Biosensor Based on Laccase-Modified Polypyrrole Polymeric Thin Film.

Authors:  Ancuța Dinu; Constantin Apetrei
Journal:  Polymers (Basel)       Date:  2022-01-22       Impact factor: 4.329

Review 3.  A Review of Sensors and Biosensors Modified with Conducting Polymers and Molecularly Imprinted Polymers Used in Electrochemical Detection of Amino Acids: Phenylalanine, Tyrosine, and Tryptophan.

Authors:  Ancuța Dinu; Constantin Apetrei
Journal:  Int J Mol Sci       Date:  2022-01-22       Impact factor: 5.923

  3 in total