Literature DB >> 34287228

Development of Second-Tier Liquid Chromatography-Tandem Mass Spectrometry Analysis for Expanded Newborn Screening in Japan.

Yosuke Shigematsu1,2, Miori Yuasa1, Nobuyuki Ishige3, Hideki Nakajima4, Go Tajima4.   

Abstract

To minimize false-positive cases in newborn screening by tandem mass spectrometry in Japan, practical second-tier liquid chromatography-tandem mass spectrometry analyses have been developed using a multimode ODS column with a single set of mobile phases and different gradient elution programs specific to the analysis of acylcarnitines, acylglycines, amino acids, and organic acids. Most analyses were performed using underivatized samples, except for analysis of methylcitric acid, and careful conditioning of the column was necessary for analyses of organic acids. Our second-tier tests enabled us to measure many metabolites useful for detection of target disorders, including allo-isoleucine, homocysteine, methylmalonic acid, and methylcitric acid. We found that accumulation of 3-hydroxyglutaric acid was specific to glutaric acidemia type I and that the ratio of 3-hydroxyisovaleric acid to 3-hydroxyisovalerylcarnitine was useful to detect newborns of mothers with 3-methylcrotonyl-CoA carboxylase deficiency. Data from the analysis of short-chain acylcarnitine and acylglycine were useful for differential diagnosis in cases positive for C5-OH-acylcarnitine or C5-acylcarnitine.

Entities:  

Keywords:  argininosuccinic acid; biotin; cobalamin; derivatization; homocystinuria; isomer; maternal 3-methylcronylglycinuria; stable-isotope dilution

Year:  2021        PMID: 34287228     DOI: 10.3390/ijns7030044

Source DB:  PubMed          Journal:  Int J Neonatal Screen        ISSN: 2409-515X


  4 in total

1.  Application of the Artificial Intelligence Algorithm Model for Screening of Inborn Errors of Metabolism.

Authors:  Muping Zhou; Liyuan Deng; Yan Huang; Ying Xiao; Jun Wen; Na Liu; Yingchao Zeng; Hua Zhang
Journal:  Front Pediatr       Date:  2022-05-19       Impact factor: 3.569

2.  Quantitation of non-derivatized free amino acids for detecting inborn errors of metabolism by incorporating mixed-mode chromatography with tandem mass spectrometry.

Authors:  Patrick D DeArmond; Dustin R Bunch
Journal:  J Mass Spectrom Adv Clin Lab       Date:  2022-05-21

3.  Incorporation of second-tier tests and secondary biomarkers to improve positive predictive value (PPV) rate in newborn metabolic screening program.

Authors:  Sarang Younesi; Bahareh Yazdani; Mohammad Mahdi Taheri Amin; Pourandokht Saadati; Soudabeh Jamali; Mohammad-Hossein Modarresi; Shahram Savad; Saloomeh Amidi; Homayoun Razavi; Soudeh Ghafouri-Fard
Journal:  J Clin Lab Anal       Date:  2022-05-02       Impact factor: 3.124

4.  Newborn Screening in Japan-2021.

Authors:  Toshihiro Tajima
Journal:  Int J Neonatal Screen       Date:  2022-01-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.