| Literature DB >> 34278227 |
Ailsa Ritchie1, Silva Atamian1, Nilpa Shah1, Alistair Laidlaw1, Christopher Hammond1,2.
Abstract
PURPOSE: The recent pandemic has identified the need for telemedicine assessment of ophthalmology patients. A vital component of such assessment is visual acuity (VA) measurement. The aim of this study was to determine the feasibility and reliability of computerised 'at home' VA measurements using COMPlog software.Entities:
Keywords: Telemedicine; amblyopia; refractive error; vision testing; visual acuity
Year: 2021 PMID: 34278227 PMCID: PMC8269772 DOI: 10.22599/bioj.179
Source DB: PubMed Journal: Br Ir Orthopt J ISSN: 1743-9868
Patient characteristics. SD = standard deviation IQR = interquartile range IMD = index of multiple deprivation.
| CHILDREN (UNDER 16 YEARS OLD) | ADULTS (OVER 16 YEARS OLD) | ALL | |
|---|---|---|---|
| Number of patients | 23 (64%) | 13 (36%) | 36 (100%) |
| Sex | 15M 8F | 7M 6F | 22 M (61%) 14 F (39%) |
| Age (years) | 9 (3), 5–15 | 49 (14), 26–75 | 23 (21), 5–75 |
| The English IMD 2019 decile (mean, range) | 6, 2–10 | 5, 2–10 | 6, 2–10 |
| Worse eye habitually corrected visual acuity (1st clinic VA test) | Median 0.12 | Median 0.04 | Median 0.1 |
| Ocular pathology in the worse eye: | |||
| No ocular pathology (Inc. refractive error and JIA with no ocular sequelae) | 11 | 1 | 12 |
| Strabismus | 2 | 8 | 10 |
| Amblyopia | 7 | 2 | 9 |
| Other pathology (Inc. cataract, retinal pathology, optic nerve pathology) | 3 | 2 | 5 |
Comparison of ‘at home’ and ‘in clinic’ VA testing.
| WORSE EYE 1ST ‘IN CLINIC’ AND ‘AT HOME’ TEST VARIABILITY (logMAR) | WORSE EYE ‘IN CLINIC’ TEST-RETEST VARIABILITY (logMAR) | WORSE EYE ‘AT HOME’ TEST-RETEST VARIABILITY (logMAR) | |
|---|---|---|---|
| Mean Difference | –0.01 | 0.01 | 0.00 |
| 95% Confidence Interval Mean | –0.03, 0.00 | –0.01, 0.01 | –0.02, 0.02 |
| Standard deviation | 0.04 | 0.03 | 0.06 |
| 95% Confidence limits of agreement | +/–0.08 | +/–0.06 | +/–0.12 |
Screen size ‘at home’ requirements for remote crowded VA testing.
| SCREEN SIZE | MAXIMUM CROWDED logMAR VA THAT CAN BE TESTED AT 3m | EXAMPLE DEVICE |
|---|---|---|
| 24” | 1.40 | Desktop screen |
| 15” | 1.10 | Laptop |
| 10” | 0.9 | Tablet |
| 6” | 0.4 | Smartphone |