Literature DB >> 34268634

Impedimetric cardiac biomarker determination in serum mediated by epoxy and hydroxyl of reduced graphene oxide on gold array microelectrodes.

S Taniselass1,2, Mohd Khairuddin Md Arshad3,4, Subash C B Gopinath2,5, M F M Fathil2, C Ibau2, Periasamy Anbu6.   

Abstract

A label-free chemical bonding strategy mediated by reduced graphene oxide (rGO) basal plane functional groups has been developed for cardiac Troponin I (cTnI) detection. Four different chemical strategies on respective electrode sensing surface were precedingly examined using electrochemical impedance spectroscopy. The impedimetric assessment was carried out by sweeping frequency at the range 0.1-500 kHz perturbated at a small amplitude of AC voltage (25 mV). The chemical strategy-4 denoted as S-4 shows a significant analytical performance on cTnI detection in spiked buffer and human serum, whereby the pre-mixture of rGO and (3-Aminopropyl)triethoxysilane (APTES) creates a large number of amine sites (-NH2), which significantly enhanced the antibody immobilization without excessive functionalization. The as-fabricated immunosensor exhibited an ultra-low limit of detection of 6.3 ag mL-1 and the lowest antigen concentration measured was at 10 ag mL-1. The immunosensor showed a linear and wide range of cTnI detection (10 ag mL-1-100 ng mL-1) in human serum with a regression coefficient of 0.9716, rapid detection (5 min of binding time), and stable and highly reproducible bioelectrode response with RSD < 5%. Hence, the demonstrated S-4 strategy is highly recommended for other downstream biosensors applications.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.

Entities:  

Keywords:  Acute myocardial infarction; Cardiac troponin; Graphene; Immunosensor; Impedance spectroscopy; Interdigitated electrode

Mesh:

Substances:

Year:  2021        PMID: 34268634     DOI: 10.1007/s00604-021-04922-x

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  12 in total

1.  Limit of blank, limit of detection and limit of quantitation.

Authors:  David A Armbruster; Terry Pry
Journal:  Clin Biochem Rev       Date:  2008-08

2.  Prolonged exposure of graphite oxide to soft X-ray irradiation during XPS measurements leads to alterations of the chemical composition.

Authors:  Chun Kiang Chua; Adriano Ambrosi; Martin Pumera
Journal:  Analyst       Date:  2013-11-21       Impact factor: 4.616

3.  Facile sonochemical synthesis of perovskite-type SrTiO3 nanocubes with reduced graphene oxide nanocatalyst for an enhanced electrochemical detection of α-amino acid (tryptophan).

Authors:  Mani Govindasamy; Sea-Fue Wang; Wei Chih Pan; Bowya Subramanian; R Jothi Ramalingam; Hamad Al-Lohedan
Journal:  Ultrason Sonochem       Date:  2019-04-13       Impact factor: 7.491

4.  Electrochemical detection of cardiac biomarker myoglobin using polyphenol as imprinted polymer receptor.

Authors:  J A Ribeiro; C M Pereira; A F Silva; M Goreti F Sales
Journal:  Anal Chim Acta       Date:  2017-06-02       Impact factor: 6.558

5.  Layered nanocomposite of zinc sulfide covered reduced graphene oxide and their implications for electrocatalytic applications.

Authors:  Subramaniyan Vinoth; Mani Govindasamy; Sea-Fue Wang; Sathiyan Anandaraj
Journal:  Ultrason Sonochem       Date:  2020-02-14       Impact factor: 7.491

6.  Self-assembled reduced graphene oxide nanoflakes assisted by post-sonication boosted electrical performance in gold interdigitated microelectrodes.

Authors:  S Taniselass; M K Md Arshad; Subash C B Gopinath; Muhammad M Ramli
Journal:  J Colloid Interface Sci       Date:  2020-05-23       Impact factor: 8.128

Review 7.  Graphene-based electrochemical biosensors for monitoring noncommunicable disease biomarkers.

Authors:  S Taniselass; M K Md Arshad; Subash C B Gopinath
Journal:  Biosens Bioelectron       Date:  2019-01-29       Impact factor: 10.618

8.  Efficient electron-mediated electrochemical biosensor of gold wire for the rapid detection of C-reactive protein: A predictive strategy for heart failure.

Authors:  A T Ezhil Vilian; Wonyoung Kim; Bumjun Park; Seo Yeong Oh; TaeYoung Kim; Yun Suk Huh; Chang Kwon Hwangbo; Young-Kyu Han
Journal:  Biosens Bioelectron       Date:  2019-07-31       Impact factor: 10.618

9.  A Possible Mechanism behind Faster Clearance and Higher Peak Concentrations of Cardiac Troponin I Compared with Troponin T in Acute Myocardial Infarction.

Authors:  Karin Starnberg; Vincent Fridén; Aida Muslimovic; Sven-Erik Ricksten; Susanne Nyström; Niklas Forsgard; Bertil Lindahl; Kristina Vukusic; Joakim Sandstedt; Göran Dellgren; Ola Hammarsten
Journal:  Clin Chem       Date:  2020-02-01       Impact factor: 8.327

Review 10.  New trends in impedimetric biosensors for the detection of foodborne pathogenic bacteria.

Authors:  Yixian Wang; Zunzhong Ye; Yibin Ying
Journal:  Sensors (Basel)       Date:  2012-03-12       Impact factor: 3.576

View more
  1 in total

1.  Multilayered Mesoporous Composite Nanostructures for Highly Sensitive Label-Free Quantification of Cardiac Troponin-I.

Authors:  Mohsen Saeidi; Mohammad Ali Amidian; Sana Sheybanikashani; Hossein Mahdavi; Homayoon Alimohammadi; Leila Syedmoradi; Fatemeh Mohandes; Ali Zarrabi; Elnaz Tamjid; Kobra Omidfar; Abdolreza Simchi
Journal:  Biosensors (Basel)       Date:  2022-05-14
  1 in total