Literature DB >> 34261020

Exploring 20 eV electron impact ionization in gas chromatography-tandem mass spectrometry for the determination of estrogenic compounds.

Alex Glineur1, Marco Beccaria2, Giorgia Purcaro3.   

Abstract

In electron ionization mass spectrometry (MS), the generation of characteristic fragmentation patterns allows reliable and sensitive identification of compounds. However, loss or a less intense signal of the molecular ion (or more diagnostic ions) can often be observed, which can be detrimental for identification and/or sensitivity, even when MS/MS approaches are applied for quantification. The benefits of applying lower ionization energy (i.e., 20 eV compared to 70 eV) using a gas chromatography (GC) - tandem MS (MS/MS) instrument were investigated in the detection of three estrogenic compounds, namely estrone (E1), 17β-estradiol (E2), and 17α-ethynylestradiol (EE2), emerging aquatic pollutants included in the European Commission Watch List. As expected, the relative intensity of molecular ions (M+.) or high-mass fragments closely related (M+.-CH3) increased significantly at 20 eV compared to 70 eV (from 4.6 % to 35.0 % for EE2, from 22.5 % to 87.3 % for E2, and from 76 % to 100 % for E1). This change in the spectrum profile led to an overall increase in the sensitivity of the compounds when detected using the multiple reaction monitoring mode. These results were compared with the instrumental limit of quantification obtained in liquid chromatography - MS/MS showing a limit of quantification of about 100-folds lower for GC-MS/MS and a completely neglectable matrix effect, thus posing the base for the development of a miniaturized sample preparation method (with an overall lower concentration factor) to achieve the challenging low limits of detection required by the EU regulation for estrogenic compounds.
Copyright © 2021. Published by Elsevier B.V.

Entities:  

Keywords:  Electron ionization (EI); Estrogenic compounds; Gas chromatography (GC); Mass spectrometry (MS); Milder ionization

Year:  2021        PMID: 34261020     DOI: 10.1016/j.chroma.2021.462359

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Novel deep eutectic solvent-based liquid phase microextraction for the extraction of estrogenic compounds from environmental samples.

Authors:  Nazir Fattahi; Mojtaba Shamsipur; Ziba Nematifar; Nasrin Babajani; Masoud Moradi; Shahin Soltani; Shahram Akbari
Journal:  RSC Adv       Date:  2022-05-13       Impact factor: 4.036

2.  [Simultaneous determination of nine estrogens in bullfrogs using filtered solid phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry].

Authors:  Qiaoli Qiu; Xiaohong Chen; Shengdong Pan; Micong Jin
Journal:  Se Pu       Date:  2022-07

3.  [Imine-linked porous covalent organic framework used for the solid-phase extraction of estrogens from honey prior to liquid chromatography-tandem mass spectrometry].

Authors:  Hui Li; Gengbiao Ren; Huijuan Li; Xiangfeng Chen; Zhiguo Zhang; Yanfang Zhao
Journal:  Se Pu       Date:  2022-08
  3 in total