Ankle blood pressure measured by automatic oscillotonometry: a comparison with Doppler pressure measurements.

M Adiseshiah1, F W Cross, P A Belsham.   

Abstract

Oscillotonometry using Dinamap machine was investigated for the measurement of ankle and brachial blood pressures in our vascular practice. It was validated by comparison with intra-arterial pressure measured by transducer. Systolic ankle and brachial pressures in 43 patients were compared using the Dinamap and Doppler techniques, and significant correlation was found. Ankle and brachial systolic, diastolic and mean pressures and ankle/brachial pressure indices for all three pressures were measured in a group of 12 normal subjects supine at rest, and after treadmill exercise, and a range of normal values defined. The main limitation of the Dinamap is its failure to measure pressures below 50mmHg. The Dinamap technique is a noninvasive, simple, reproducible and quick method of measuring ankle and brachial pressures in vascular surgical practice.

Entities:  

Mesh:

Year:  1987        PMID: 3426091      PMCID: PMC2498533     

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  6 in total

1.  Ankle systolic pressure measurements in arterial disease affecting the lower extremities.

Authors:  S T Yao; J T Hobbs; W T Irvine
Journal:  Br J Surg       Date:  1969-09       Impact factor: 6.939

2.  An assessment of the Dinamap 845.

Authors:  P Hutton; J Dye; C Prys-Roberts
Journal:  Anaesthesia       Date:  1984-03       Impact factor: 6.955

3.  Automatic blood pressure monitors. A clinical evaluation of five models in adults.

Authors:  C J Johnson; J H Kerr
Journal:  Anaesthesia       Date:  1985-05       Impact factor: 6.955

4.  Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.

Authors:  S N Hunyor; J M Flynn; C Cochineas
Journal:  Br Med J       Date:  1978-07-15

5.  Variability of Doppler ankle pressures with arterial occlusive disease: an evaluation of ankle index and brachial-ankle pressure gradient.

Authors:  J D Baker; D E Dix
Journal:  Surgery       Date:  1981-01       Impact factor: 3.982

6.  Sphygmomanometers in hospital and family practice: problems and recommendations.

Authors:  M J Burke; H M Towers; K O'Malley; D J Fitzgerald; E T O'Brien
Journal:  Br Med J (Clin Res Ed)       Date:  1982-08-14
  6 in total
  2 in total

1.  Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index?

Authors:  Euan MacDonald; Paul Froggatt; Gwen Lawrence; Stephen Blair
Journal:  J Clin Monit Comput       Date:  2008-11-06       Impact factor: 2.502

2.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.