Hessel Engelbregt1,2, Marinda Barmentlo1, Daniel Keeser2, Oliver Pogarell2, Jan Berend Deijen3,4.
Abstract
Nowadays a popular technique to improve mood and cognition is auditory beat stimulation (ABS), which is thought to induce a frequency-following response of brainwaves. The main types of ABS are monaural beats (MB) and binaural beats (BB). BB involves the presentation of a specific frequency to one ear and another frequency to the other ear which may induce neural entrainment. A difference between the frequencies of 40 Hz is assumed to improve cognition. The present study examined the effect of 40 Hz binaural beats (BB) and monaural beats (MB) on attention and electroencephalography (EEG). A total of 25 first-year psychology students (11 males, 14 females) performed a Flanker task while EEG was recorded during the 5 min-presentation of pink noise (PN), MB and BB. With respect to attention, as measured by the Flanker task, the number of false responses in the BB condition was smaller than that in the PN condition while the number of false responses in the MB condition was larger as compared to the PN condition. As there was no association of BB with a consistent increase in absolute 40 or 45 Hz power compared to PN or MB, EEG recordings could not confirm the hypothesized neural entrainment in the brain. Overall, the current findings show that listening to 40 Hz BB improves attention but do not show the occurrence of neural entrainment. Future research is recommended to include a larger sample, to use a broader cognitive test battery and to present auditory beats with a longer duration.Entities:
Keywords: Attention; Auditory beat stimulation; Binaural beats; EEG; Flanker task; Monaural beats
Mesh:
Year: 2021 PMID: 34245340 PMCID: PMC8448709 DOI: 10.1007/s00221-021-06155-z
Source DB: PubMed Journal: Exp Brain Res ISSN: 0014-4819 Impact factor: 1.972
Mean (M), standard deviation (SD) and median (Mdn) of reaction time (ms) on the Flanker task in the pink noise (PN), monaural beat (MB) and binaural beat (BB) condition (n = 24)
| PN | MB | BB | |||||||
|---|---|---|---|---|---|---|---|---|---|
| M | SD | Mdn | M | SD | Mdn | M | SD | Mdn | |
| Reaction time (ms) | 0.712 | 0.024 | 0.673 | 0.7108 | 0.019 | 0.702 | 0.733 | 0.035 | 0.686 |
Fig. 1Mean (square root of) number (+ SE) of false responses on the Flanker task in PN, MB and BB condition (n = 24)
Friedman test results of absolute power (μV2) of separate electrodes for 40 Hz (n = 19)
| PN | MB | BB | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| SD | Mdn | SD | Mdn | SD | Mdn | |||||
| F3 | 0.224 | 0.179 | 0.186 | 0.247 | 0.159 | 0.217 | 0.176 | 0.084 | 0.158 | 0.249 |
| F4 | 0.247 | 0.324 | 0.179 | 0.245 | 0.150 | 0.209 | 0.200 | 0.135 | 0.174 | 0.211 |
| F7 | 0.715 | 1.321 | 0.341 | 0.709 | 1.419 | 0.337 | 0.674 | 1.585 | 0.213 | 0.348 |
| F8 | 0.755 | 1.587 | 0.272 | 0.741 | 1.374 | 0.333 | 0.724 | 1.572 | 0.271 | 1.000 |
| Fp1 | 0.257 | 0.159 | 0.210 | 0.268 | 0.193 | 0.237 | 0.237 | 0.170 | 0.172 | 0.411 |
| Fp2 | 0.372 | 0.417 | 0.241 | 0.487 | 0.759 | 0.282 | 0.294 | 0.524 | 0.167 | 0.066 |
| Fz | 0.183 | 0.101 | 0.160 | 0.232 | 0.146 | 0.176 | 0.166 | 0.070 | 0.160 | |
| T3 | 0.513 | 0.952 | 1.040 | 0.620 | 2.502 | 7.603 | 0.628 | 1.222 | 1.917 | 0.604 |
| T4 | 0.946 | 0.961 | 0.720 | 0.802 | 2.018 | 4.034 | 0.633 | 0.978 | 0.904 | 0.728 |
| T5 | 0.801 | 0.643 | 0.515 | 0.545 | 0.657 | 0.630 | 0.369 | 0.575 | 0.377 | 0.452 |
| T6 | 0.846 | 0.756 | 0.547 | 0.610 | 0.815 | 0.835 | 0.520 | 0.674 | 0.525 | 0.571 |
PN pink noise, MB monaural beats, BB binaural beats, M mean, SD standard deviation, Mdn median
Benjamini–Hochberg significant p value is shown in bold
Friedman test results of absolute power (μV2) of separate electrodes for 45 Hz (n = 19)
| PN | MB | BB | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| SD | Mdn | SD | Mdn | SD | Mdn | |||||
| F3 | 0.234 | 0.195 | 0.173 | 0.207 | 0.137 | 0.172 | 0.195 | 0.146 | 0.158 | 0.678 |
| F4 | 0.279 | 0.440 | 0.136 | 0.184 | 0.117 | 0.152 | 0.206 | 0.162 | 0.154 | 0.411 |
| F7 | 0.687 | 1.340 | 0.347 | 0.724 | 1.360 | 0.295 | 0.556 | 1.128 | 0.202 | 0.348 |
| F8 | 0.639 | 1.238 | 0.267 | 0.671 | 1.395 | 0.245 | 0.686 | 1.579 | 0.228 | 0.846 |
| FP1 | 0.415 | 0.501 | 0.204 | 0.278 | 0.248 | 0.199 | 0.358 | 0.520 | 0.188 | 0.066 |
| FP2 | 0.344 | 0.366 | 0.228 | 0.331 | 0.448 | 0.168 | 0.285 | 0.440 | 0.169 | 0.092 |
| Fz | 0.201 | 0.150 | 0.112 | 0.172 | 0.109 | 0.122 | 0.181 | 0.112 | 0.161 | 0.801 |
| T3 | 1.075 | 1.200 | 0.731 | 2.865 | 9.207 | 0.576 | 1.146 | 1.835 | 0.535 | 0.801 |
| T4 | 0.927 | 0.666 | 0.867 | 1.716 | 3.960 | 0.478 | 0.911 | 0.842 | 0.633 | 0.348 |
| T5 | 0.585 | 0.436 | 0.450 | 0.573 | 0.713 | 0.350 | 0.645 | 0.506 | 0.498 | |
| T6 | 0.674 | 0.509 | 0.429 | 0.661 | 0.635 | 0.401 | 0.565 | 0.387 | 0.539 | 0.678 |
PN pink noise, MB monaural beats, BB binaural beats, M mean, SD standard deviation, Mdn median
Benjamini–Hochberg significant p value is shown in bold
Fig. 2Topoplots of differences in absolute power between the BB and MB condition and between BB and PN condition
Non-parametric Friedman test results of the absolute power (μV2) of averaged frontal and averaged temporal electrodes under the pink noise (PN), monaural beat (MB) and binaural beat (BB) condition (n = 19)
| Hz | PN | MB | BB | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| M | SD | Mdn | SD | Mdn | SD | Mdn | |||||
| Frontal | 40 | 0.494 | 0.404 | 0.563 | 0.261 | 0.428 | 0.495 | 0.317 | 0.360 | 0.574 | 0.187 |
| 45 | 0.291 | 0.412 | 0.541 | 0.293 | 0.372 | 0.487 | 0.239 | 0.360 | 0.500 | 0.204 | |
| Temporal | 40 | 0.801 | 0.828 | 0.530 | 0.658 | 1.498 | 3.099 | 0.672 | 0.862 | 0.777 | 0.724 |
| 45 | 0.801 | 0.815 | 0.555 | 0.711 | 1.454 | 3.579 | 0.577 | 0.817 | 0.725 | 0.651 | |
Hz hertz, M mean, SD standard deviation, Mdn median
Spearman correlations of the total absolute power (μV2) and performance (RT and number of false responses) on the Flanker task under the pink noise (PN), monaural beat (MB) and binaural beat (BB) condition (n = 19)
| Reaction time | False responses | |||||||
|---|---|---|---|---|---|---|---|---|
| 40 Hz | 45 HZ | 40 Hz | 45 Hz | |||||
| PN | − 0.009 | 0.355 | 0.096 | 0.191 | 0.036 | 0.626 | 0.049 | 0.509 |
| MB | 0.184 | 0.177 | − 0.250 | − 0.242 | ||||
| BB | 0.100 | 0.174 | 0.094 | 0.201 | − 0.151 | − 0.156 | ||
Hz hertz