Literature DB >> 34240061

A three-year randomized clinical trial evaluating direct posterior composite restorations placed with three self-etch adhesives.

Joseph Sabbagh1, Layal El Masri1, Jean Claude Fahd1, Paul Nahas1.   

Abstract

AIM: To compare the clinical performance of composite restorations placed with a universal adhesive, one-step and two-step self-etch adhesives in class I and II posterior cavities.
MATERIALS AND METHODS: In this in vivo study, 46 volunteers presenting with at least three carious lesions were included. Each participant received the three restorative systems: universal adhesive/nanofilled composite (Scotchbond Universal/Filtek Z350 XT: SBU/FZXT), one-step self-etch adhesive/microhybrid composite (G-aenial bond/G-aenial Posterior: GB/GP) and the two-step self-etch adhesive/nanohybrid composite (OptiBond XTR/Herculite Ultra: OBX/HU). The adhesives were all placed in self-etch mode. In total, 138 restorations were evaluated at baseline and at 6,12 and 36 months using the modified United States Public Health Service criteria. Data were analysed using Kruskal-Wallis, Mann-Whitney U, Friedman and Wilcoxon non-parametric tests (p < .05). Ninety-one restorations were evaluated at 36 months.
RESULTS: Seven restorations, three SBU/FZXT, three GB/GP and one OBX/HU failed during this study. The reasons for failure were marginal fracture and secondary caries. SBU/FZXT restorations showed significant marginal deterioration in all parameters. Overall success rates were: 93.5% (SBU/FZXT), 96.6% (GB/GP) and 96.8% (OBX/HU).
CONCLUSIONS: After three years, the three restorative systems have comparable clinical effectiveness and success rates, except for the marginal integrity, that was suboptimal for both the SBU/FZXT and GB/GP restorations in comparison to the OBX/HU restorations.
© 2021 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.

Entities:  

Keywords:  Composite restorations; USPHS criteria; in vivo study; posterior teeth; self-etch adhesives; universal adhesives

Year:  2021        PMID: 34240061      PMCID: PMC8238063          DOI: 10.1080/26415275.2021.1939034

Source DB:  PubMed          Journal:  Biomater Investig Dent        ISSN: 2641-5275


Introduction

Resin composites and adhesives are considered state of art in today’s restorative dentistry. These materials have evolved rapidly since they were first introduced, resulting in more durable and aesthetic restorations [1]. This led to a paradigm shift in dentistry, away from amalgam towards the more tooth-structure preserving composites [2]. However, there are various setbacks that are composite-related, including wear, microleakage, discoloration, postoperative sensitivity and polymerization shrinkage [3,4]. In an attempt to overcome the aforementioned problems, different formulations of resin composites were developed with the aid of nanotechnology such as nanofilled and nanohybrid composites. Manufacturers claimed that these composites have improved physical properties, superior polishability and better gloss retention, than the commonly used microhybrid resin composites. However, recent studies, including systematic reviews and meta-analyses, have not corroborated these claims [5,6]. Moreover, similar clinical behaviour was observed for nanocomposites and microhybrid composites [2]. In parallel to the development of resin composites, the adhesive systems have significantly evolved, simplifying application procedures, hence more user-friendly. In addition, self-etch (SE) adhesives were sought improved through changes in their photo-initiators and by the addition of functional monomers. Although, they imply a shorter application protocol, but their ability to adequately etch enamel has been questioned [7]. Strong SE adhesives were then introduced, which bonded effectively to enamel but formed weak dentin bonds and have been associated with a higher annual failure rate (5.4%) when compared to mild SE adhesives (3.6%) [8]. As a consequence, the idea of selectively etching the enamel with phosphoric acid prior to the application of mild SE adhesives was born [7]. A recent development in adhesive systems is the universal adhesives (UAs). They are one-step SE adhesives, which can be applied using an etch-and-rinse, self-etch or selective enamel-etch mode [7]. This allows dentists to select their adhesive technique according to their preference and the clinical situation [9,10]. Universal adhesives range from ultra-mild (pH ≥ 2.5) to mild (pH ≈ 2) and contain functional phosphate and/or carboxylate monomers that can bond chemically to dental tissues [7,11-13]. According to in vitro studies, their bond strength to dentin is determined by the pH, while the bond to enamel is enhanced when used in selective enamel-etch mode [14]. This was confirmed by a five-year clinical assessment, in which the universal adhesive performance was superior when applied using the etch and rinse (E&R) mode compared to the SE mode [15]. Existing data, have shown that the two-step SE adhesives, form a more stable bond and durable restorations than the simplified SE adhesives [8]. Simplified adhesives are well accepted by dentists and are available from numerous manufacturers. But presently, there is no agreement in the literature concerning the best adhesive for clinical use in the restoration of Class I and II posterior cavities. The purpose of this randomized clinical trial was to compare the performance of nanofilled, microhybrid and nanohybrid resin composites bonded respectively with a universal adhesive, a one-step and a two-step self-etch adhesives in Class I and II posterior cavities, after thirty-six months, using the modified United Stated Public Health Services criteria (USPHS). The null hypothesis (H0) tested was that there would be no differences in the clinical performance for the three restorative systems after 3 years.

Materials and methods

Study design

This randomized trial was a single-site study conducted at university dental clinics in the Department of Restorative and Aesthetic Dentistry, Faculty of Dental Medicine, Lebanese University, Lebanon. The study was designed according to the Consolidated Standards of Reporting Trials (CONSORT) statement (Figure 1). A consent form and the protocol were submitted, reviewed and approved by the Ethical Committee of the Lebanese University. All procedures were performed according to the ethical standards of the institutional and/or national research committee and world medical association Declaration of Helsinki [16]. Selected patients were assessed for eligibility for participation, using the following inclusion criteria: (1) teeth with shallow to moderate Class I or II carious lesions, (2) a good periodontal status, (3) the absence of pulp pathology, (4) the absence of restorations on selected teeth, (5) the absence of parafunctional habits, (6) the included teeth were vital. Patients were healthy, physically and mentally with a non-compromised medical history and with the absence of allergic history to methacrylate. Patients that did not fit any of these criteria were excluded from the study. They were informed with the clinical procedure and signed an informed consent form.
Figure 1.

CONSORT Flow diagram.

CONSORT Flow diagram.

Restorative procedure

This clinical study included 138 posterior teeth in 46 patients (22 males and 24 females) with three cavities in each patient. The age range of the patients was between 20–55 years. The three cavities were randomly restored using the three different restorative systems. For each cavity in each patient, a coin was tossed to randomize the selection of materials. Heads denoted the Universal one-step self-etch adhesive and a nanofilled composite (SBU/FZXT); tails denoted the one-step self-etch adhesive and a microfilled composite (GB/GP); and the third cavity was assigned to the two-step self-etch adhesive and a nanohybrid composite (OBX/HBU). A modification to the randomization process within patients was made to ensure the equal distribution of the materials among tooth type and class type (Tables 1 and 2). Operators were not blinded to the materials used, as they can be easily identified from the application protocol. The sample size of this study (46 teeth per material) was chosen according to the recommendations of the ADA Acceptance Guidelines, where at least 30 restorations per material is required in the original study design [17].
Table 1.

Distribution of cavity class among groups.

Cavity ClassRestorative systems
Sig.
SBU/FZXTGB/GPOBX/HU
Class I (with Buccal, palatal or lingual extension)3 (6.5%)3 (6.5%)1 (2.2%)0.871Fisher ExactTest
Class I11 (23.9%)12 (26.1%)12 (26.1%)
Class II OD, OM21 (45.7%)20 (43.5%)20 (43.5%)
Class II MOD11 (23.9%)11 (23.9%)13 (28.3%)
Total46 (100.0%)46 (100.0%)46 (100.0%)
Table 2.

Distribution of tooth types among groups.

 Restorative systems
Sig.
ToothSBU/FZXTGB/GPOBX/HU 
Premolar21 (45.2%)19 (45.2%)20 (51.6%)0.971Fisher Exact Test
Molar25 (54.8%)27 (54.8%)26 (48.4%)
Total46 (100.0%)46 (100.0%)46 (100.0%)
Distribution of cavity class among groups. Distribution of tooth types among groups. Three calibrated dental residents from the Department of Restorative and Aesthetic Dentistry Department, performed the operative procedures. Bite-wing radiographs were taken before cavity preparation and the resin composite shade was selected. Local anaesthesia (Septanest,1:200.000, Septodont, Saint-Maur-des - Fossés, France) was given to patients as needed to avoid discomfort during the restorative procedure. Conservative cavities were prepared, using cylindrical diamond burs (SS White, USA) at high-speed with water cooling and round carbide burs (SS White, USA) at low speed were used to remove caries. The cavity preparations were shallow to moderate therefore a liner or base was not indicated. The location of the cervical margins was not recorded. Rubber dam was used to isolate the operative field, to provide ideal clinical conditions. For class II restorations, a pre-mounted metallic matrix system (SuperMat, Kavo-Kerr, Bioggio, Switzerland) and wooden wedges were placed to restore the anatomical shape and the proximal contact of the teeth. The restorations were distributed within one patient between carious molars and premolars (3 molars or 3 premolars or 1 molar and 2 premolars or 2 premolars and 1 molar). Cavities were randomly distributed to the following test restorative systems: SBU/FZXT: 1-step self-etch universal adhesive, Scotch Bond universal and a nanofilled composite, Filtek Z350 XT (3 M ESPE; Seefeld, Germany), GB/GP: 1-step self-etch adhesive, G-aenial bond and a microfilled hybrid composite, G-aenial Posterior (GC Corporation; Tokyo, Japan), OBX/HU: 2-step self-etch adhesive, OptiBond XTR and a nanohybrid composite, Herculite Ultra (Kavo Kerr Corp; Orange, CA, USA), (Table 3). The adhesives were all used in a self-etch mode. The three restorative systems (adhesive/composite) were placed in every patient to provide same subject control. Following the application of the adhesive systems as per manufacturer instructions, the resin composites were placed by the layering technique (2-mm-thick increments) and light-cured for 20 s using a Demi LED light curing device (Demetron, Kerr, USA). Finishing and polishing procedure was performed using carbide finishing burs and Identoflex and Occlubrush points (Kavo- Kerr, Bioggio, Switzerland).
Table 3.

Name, composition, application and batch numbers of used materials.

AdhesiveComposition and pHaApplicationaResin CompositeComposite Compositiona
Scotchbond Universal(3M ESPE, Seefeld, Germany)One-bottle system self- etchLot 532117AdhesiveMDP Phosphate monomer, Dimethacrylate Resins, HEMA,Vitrebond copolymer, Filler, Ethanol, Water, Intiators, Silane. Ultra-mild (pH≈2.7)1.Apply scotch bond universal adhesive to prepared tooth. 2. Rub for 20 seconds. 3.Gently air-dry adhesive for 5 seconds to evaporate solvent.4. Light cure for 10 seconds.Filtek Z350Lot 497440ResinUDMA, Bis-EMA, Bis-GMA, TEGDMAFillersSilica (20 nm non-agglomerated/aggregated) zirconia (4–11 nm non-agglomerated/aggregated and agglomerated)clusters, zirconia/ silica aggregated particles (20 nm silica particles combined with 4-11 nm zirconia.
G-aenial Bond (GC Corporation, Tokyo, JAPAN)One-bottle system self- etchLot 14101014-META Phosphoric acid ester monomer, Dimethacrylate monomers, Distilled water, Acetone, Silicon dioxide, Photo-initiatorIntermediately strong (pH≈1.5)1.Shake bottle of G-Bond 2. Apply to the enamel and dentin using disposable applicator brushes. 3. Leave undisturbed for 10 seconds after application.4. Dry thoroughly for 5 Seconds5.Light cure for 10 seconds.G-aenial posteriorLot201204091ResinUDMADimethacrylate co-monomersFillersmilled pre-polymerized fillers averaging 16 to 17μ in size.Fluoroaluminosilicate glass.Fumed silica is dispersed between the pre-polymerized fillers and the other inorganic fillers.
OptiBond XTR (Kavo Kerr; Orange, CA, USA) Two-bottle system Self-etchLot 4866387Lot 4866388Primer: Glycerol diphosphate monomer (GPDM), hydrophilic co-monomers and di-functional methacrylate monomers, water, acetone, ethyl alcohol, camphorquinone (pH≈2.4)Adhesive: hydrophobic cross-linking monomers, ethyl alcohol, camphorquinone, 0.4-μm barium glass 15%, sodium hexafluorosilicate Mild(pH≈3.4)1. Apply OptiBond XTR Primer to enamel/dentin using scrubbing motion. 2. Air thin with medium pressure. 3. Shake OptiBond XTR adhesive briefly. Apply to enamel/dentin surface using light brushing motion. 4.Air thin with medium air pressure and then strong air for at least 5 seconds. 5. Light cure for 10 seconds. 6. Place composite according to manufacturer’s instructions for use and light cure.Herculite UltraLot 3318302ResinUncured Methacrylate Ester Monomers FillersThree fillers—prepolymerized filler (PPF), silica nanofillers (20 − 50 nm), Barium glass (0.4 micron).

HEMA: Hydroxyethylmethacrylate; MDP: Methacryloyloxydecyl dihydrogen phosphate; TEGDMA: trietyleneglycoldimethacrylate; UDMA: Urethanedimethacrylate; GPDM: Glycerol-phosphate-dimethacrylate; Bis-GMA: Bisphenol A-glycidyl methacrylate; Bis-EMA: Bisphenol A ethoxylate dimethacrylates; 4-META: 4-methacryloxyethyl trimellitate anhydride.

aAccording to manufacturers’ MSDS (material safety data sheet).

Name, composition, application and batch numbers of used materials. HEMA: Hydroxyethylmethacrylate; MDP: Methacryloyloxydecyl dihydrogen phosphate; TEGDMA: trietyleneglycoldimethacrylate; UDMA: Urethanedimethacrylate; GPDM: Glycerol-phosphate-dimethacrylate; Bis-GMA: Bisphenol A-glycidyl methacrylate; Bis-EMA: Bisphenol A ethoxylate dimethacrylates; 4-META: 4-methacryloxyethyl trimellitate anhydride. aAccording to manufacturers’ MSDS (material safety data sheet).

Evaluation

Restorations were evaluated at baseline and at six, 12 and 36 months, by two calibrated examiners, that were blinded to the tested groups using the modified USPHS criteria (Table 4) [18]. The evaluations included mirrors, probes, radiographs and intra oral photographs. When a difference in scores was observed between evaluators, a third assessor evaluated the restorations and a consensus was reached.
Table 4.

Modified US Public Health Service criteria for direct clinical evaluation of restorations.

CriteriaDefinition
Anatomical formA: Restoration is continuous with existing anatomical form.B: Restoration is discontinuous with existing anatomical form but missing material is not sufficient to expose dentin or base. C: sufficient material is lost to expose dentin or base.
Marginal adaptationA: The explorer does not catch.B: Explorer catches, no crevice is visible in to which explorer will penetrate.C: Obvious crevice at margin, enamel, dentin or base exposed.D: Restoration is mobile, fractured or missing.
Color matchA: Restoration matches the shade and translucency of adjacent tooth structure. B: Perceptible mismatch, but mismatch is within the normal range of tooth shades. C: The mismatch is outside the normal range of tooth shades and translucency.
Marginal discolorationA: No discoloration anywhere along the margin.B: Superficial staining (removable, usually localized).C: Deep staining (not removable, generalized).
Surface textureA: No surface roughness or pits.B: Slight surface roughness or pitted surface.C: Obvious surface roughness or pitted surface.
Secondary cariesA: No caries is present.D: Caries is present.

A: Alpha; B: Bravo; C: Charlie; D: Delta.

Modified US Public Health Service criteria for direct clinical evaluation of restorations. A: Alpha; B: Bravo; C: Charlie; D: Delta.

Statistical analysis

Data were assessed using descriptive statistics. The Kruskal–Wallis and Mann–Whitney U non-parametric tests were used to compare the performance of the three restorative systems at each evaluation time (baseline, 6 months, 12 months and 36 months). Friedman and Wilcoxon non-parametric tests were used to compare the differences in the ratings of each restorative system at baseline and at 6, 12 and 36 months. The ‘Alpha’ error was set at 0.05. Fisher Exact Test was used to confirm that the cavity classes and the tooth types were equitably distributed among groups (-p-value >.05). The software program used was IBM SPSS 18 for Windows (IBM Corporation, Armonk, NY, USA)

Results

A total of 138 restorations were initially placed in 46 patients. They were distributed evenly among the different types of teeth, 60 (43.5%) restorations were placed in premolars and 78 (56.5%) in molars (Tables 1 and 5). Ninety-one restorations were evaluated at the 36 months recall with a 66% recall rate. Overall, 15 patients did not attend the last recall for the following reasons: four relocated, one started an orthodontic treatment and 10 refrained from attending their appointments for unknown reasons (Figure 1). Seven restorations, three SBU/FZXT, three GB/GP and one OBX/HU failed during 36 months of clinical service. The reasons for failure were marginal fracture and secondary caries as shown in Table 6. Success rates were: 93.5% (SBU/FZXT), 96.6% (GB/GP) and 96.8% (OBX/HU). The clinical evaluation ratings of the restorations are shown in Table 7. All restorations obtained Alpha ratings, except for 14 restorations that rated Bravo at baseline (marginal adaptation: 3, anatomical form: 2, surface texture: 2 and colour match: 7). Failed restorations were replaced, but included in the statistical analysis as ‘Delta’. In general, deterioration in all parameters was observed for SBU/FZXT restorations, except for the colour match criterion where no significant change was recorded. While in groups GB/GP and OBX/HU, all parameters did not show any significant change except for colour match for GB/GP restorations. A significant difference between the three groups was registered at 6, 12 and 36 months, for marginal adaptation and surface texture and at 36 months for marginal discoloration (Table 5).
Table 5.

Descriptive statistics of the evaluated parameters for each restorative system.

 SBU/FZXTGB/GPOBX/HUp Value
Anatomical Form
Evaluation period
Baseline1.02 ± 0.1474 (n = 46)1.02 ± 0.147 (n = 46)1.00 ± 0.000 (n = 46).604
6 months1.07 ± 0.3274,5 (n = 46)1.02 ± 0.147 (n = 46)1.00 ± 0.000 (n = 46).360
12 months1.11 ± 0.3795,6 (n = 46)1.07 ± 0.327 (n = 46)1.00 ± 0.000 (n = 46).127
36 months1.15 ± 0.4706 (n = 31)1.04 ± 0.206 (n = 29)1.04 ± 0.295 (n = 31).182
-p-value0.0360.8010.392 
Marginal Adaptation
Baseline1.04 ± 0.2064 (n = 46)1.02 ± 0.147 (n = 46)1.00 ± 0.000 (n = 46).362
6 months1.17 ± 0.4372/4,5 (n = 46)1.11 ± 0.4821,2 (n = 46)1.00 ± 0.0001 (n = 46).020
12 months1.30 ± 0.5113/5,6 (n = 46)1.17 ± 0.5702 (n = 46)1.02 ± 0.1471 (n = 46).001
36 months1.48 ± 0.7522/6 (n = 31)1.09 ± 0.3541 (n = 29)1.11 ± 0.4821 (n = 31)<.001
-p-value<0.0010.1560.066 
Colour Match
Baseline1.04 ± 0.206 (n = 46)1.02 ± 0.1474 (n = 46)1.09 ± 0.285 (n = 46).351
6 months1.04 ± 0.206 (n = 46)1.02 ± 0.1474 (n = 46)1.09 ± 0.285 (n = 46).351
12 months1.07 ± 0.250 (n = 46)1.04 ± 0.2064 (n = 46)1.09 ± 0.285 (n = 46).702
36 months1.11 ± 0.315 (n = 31)1.17 ± 0.4375 (n = 29)1.09 ± 0.285 (n = 31)0.592
-p-value0.0660.012 
Marginal discoloration
Baseline1.00 ± 0.0004 (n = 46)1.00 ± 0.000 (n = 46)1.00 ± 0.000 (n = 46)1.000
6 months1.04 ± 0.2064 (n = 46)1.02 ± 0.147 (n = 46)1.00 ± 0.000 (n = 46).362
12 months1.13 ± 0.3414,5 (n = 46)1.07 ± 0.250 (n = 46)1.04 ± 0.206 (n = 46).279
36 months1.26 ± 0.444 2/5 (n = 31)1.07 ± 0.2501(n = 29)1.04 ± 0.2061 (n = 31).002
-p-value<0.0010.2340.112 
Surface Texture
Baseline1.04 ± 0.2064 (n = 46)1.00 ± 0.000 (n = 46)1.00 ± 0.000 (n = 46).133
6 months1.13 ± 0.3412/5 (n = 46)1.04 ± 0.2061 (n = 46)1.00 ± 0.0001 (n = 46).025
12 months1.13 ± 0.3412/5 (n = 46)1.07 ± 0.2501,2 (n = 46)1.00 ± 0.0001 (n = 46).041
36 months1.13 ± 0.3412/5 (n = 31)1.11 ± 0.3152 (n = 29)1.00 ± 0.0001 (n = 31).048
-p-value0.0070.112 
Secondary caries
Baseline1.00 ± 0.000 (n = 46)1.00 ± 0.000 (n = 46)1.00 ± 0.000 (n = 46)1.000
6 months1.00 ± 0.000 (n = 46)1.02 ± 0.147 (n = 46)1.00 ± 0.000 (n = 46).368
12 months1.02 ± 0.147 (n = 46)1.04 ± 0.206 (n = 46)1.00 ± 0.000 (n = 46).362
36 months1.04 ± 0.206 (n = 31)1.07 ± 0.250 (n = 29)1.00 ± 0.000 (n = 31).236
-p-value0.1940.1721.000 

1,2,3: Significant difference between the restorative materials (p < .05).

4,5,6: Significant difference in comparison with baseline for each restorative material (p < .05).

n: number of restorations.

Table 6.

Failed restorations during the 36 months evaluation, tooth type, year, and reason for failure.

Restorative systemCavity class/ ToothNumber of failed restorationsMonth(M)Reasons
Scotchbond UniversalClass II M112 MSecondary caries
Filtek Z350 XTClass II M136 MMarginal fracture
 Class II Pm136 MMarginal fracture
G-aenial bondClass II M16 MSecondary caries
G-aenial PosteriorClass II M112 MMarginal fracture
 Class II M112 MSecondary caries
OptiBond XTRClass II M136 MMarginal fracture
Herculite Ultra    

M: Molar; Pm: Premolars.

Table 7.

Number and percentages of restorations for each group evaluated according to the modified USPHS criteria.

SBU/FZXT
GB/GP
OBX/HU
 BL6 months12 months36 monthsBL6 months12 months36 monthsBL6 months12 months36 months
Anatomical form
A45 (97.8%)44 (95.7%)42 (91.3%)28 (90.3%)45 (97.8%)45 (97.8%)44 (95.7%)29 (100.0%)46 (100%)46 (100%)46 (100%)30 (96.8%)
B1 (2.2%)1 (2.2%)3 (6.5%)1 (2.2%)1 (6.5%)1 (2.2%)1 (2.2%)0 (0%)0 (0%)0 (0%)0 (0%)0 (0%)
C0 (0%)1 (2.2%)1 (2.2%)2 (4.3%)0 (0%)0 (0%)1 (2.2%)0 (0 %)0 (0%)0 (0%)0 (0%)1 (3.2%)
Marginal adaptation
A44 (95.7%)39 (84.8%)33 (71.7%)18 (58.1%)45 (97.8%)43 (93.5%)43 (93.5%)27 (93.1%)46 (100%)46 (100%)45 (97.8%)29 (93.5%)
B2 (4.3%)6 (13.0%)12 (26.1%)11 (35.5%)1 (2.2%)2 (4.3%)1 (2.2%)1 (3.4%)0 (0%)0 (0%)1 (2.2%)1 (3.2%)
C0 (0%)1 (2.2%)1 (2.2%)0 (0%)0 (0%)1 (2.2%)1 (2.2%)1 (3.4%)0 (0%)0 (0%)0 (0%)0 (0%)
D0 (0%)0 (0%)0 (0%)2 (6.5%)0 (0%)0 (0%)1 (2.2%)0 (0%)0 (0%)0 (0%)0 (0%)1 (3.2%)
Colour match
A44 (95.7%)44 (95.7%)43 (93.5%)27 (87.1%)45 (97.8%)45 (97.8%)44 (95.7%)26 (89.7%)42 (91.3%)42 (91.3%)42 (91.3%)28 (90.3%)
B2 (4.3%)2 (4.3%)3 (6.5%)4 (12.9%)1 (2.2%)1 (2.2%)2 (4.3%)2 (6.9%)4 (8.7%)4 (8.7%)4 (8.7%)3 (9.7%)
C0 (0%)0 (0%)0 (0%)0 (0%)0 (0%)0 (0%)0 (0%)1 (3.4%)0 (0%)0 (0%)0 (0%)0 (0%)
Marginal discoloration
A46 (100%)44 (95.7%)40 (87.0%)22 (71.0%)46 (100%)45 (97.8%)43 (93.5%)26 (89.7%)46 (100%)46 (100%)44 (95.7%)30 (96.8%)
B0 (0%)2 (4.3%)6 (13.0%)9 (29.0%)0 (0%)1 (2.2%)3 (6.5%)3 (10.3%)0 (0%)0 (0%)2 (4.3%)1 (3.2%)
Surface texture
A44 (95.7%)40 (87.0%)40 (87.0%)27 (87.1%)46 (100%)44 (95.7%)43 (93.5%)26 (89.7%)46 (100%)46 (100%)46 (100%)31 (100.0%)
B2 (4.3%)6 (13.0%)6 (13.0%)4 (12.9%)0 (0%)2 (4.3%)3 (6.5%)3 (10.3%)0 (0%)0 (0%)0 (0%)0 (0%)
Secondary caries
A46 (100%)46 (100%)45 (97.8%)30 (96.8%)46 (100%)45 (97.8%)44 (95.7%)28 (96.6%)46 (100%)46 (100%)46 (100%)31 (100.0%)
D0 (0%)0 (0%)1 (2.2%)1 (3.2%)0 (0%)1 (2.2%)2 (4.3%)1 (2.2%)0 (0%)0 (0%)0 (0%)0 (0%)

A: Alpha, B: Bravo, C: Charlie, D: Delta, SBU/FZXT: Scotch Bond Universal/Filtek Z350 XT, GB/GP: G- aenial Bond/ G-aenial Posterior, OBX/HU: Opti Bond XTR/Herculite Ultra.

Descriptive statistics of the evaluated parameters for each restorative system. 1,2,3: Significant difference between the restorative materials (p < .05). 4,5,6: Significant difference in comparison with baseline for each restorative material (p < .05). n: number of restorations. Failed restorations during the 36 months evaluation, tooth type, year, and reason for failure. M: Molar; Pm: Premolars. Number and percentages of restorations for each group evaluated according to the modified USPHS criteria. A: Alpha, B: Bravo, C: Charlie, D: Delta, SBU/FZXT: Scotch Bond Universal/Filtek Z350 XT, GB/GP: G- aenial Bond/ G-aenial Posterior, OBX/HU: Opti Bond XTR/Herculite Ultra.

Anatomical form

In terms of the anatomical form criteria, there was a statistically significant decrease in ratings, during the 36 months, in Filtek Z350 XT composite restorations (SBU/FZXT group). Unlike the G-aenial Posterior (GB/GP group) and Herculite Ultra composite restorations (OBX/HU group) that showed an insignificant decrease during the evaluation periods. Four restorations (2 Filtek Z350 XT at 6 and 12 months, 1 G-aenial Posterior at 12 months and 1 Herculite Ultra at 36 months) with wear were detected and rated Charlie. However, statistically significant differences were not found between the three different composites from baseline to 36 months (p > .05). The restorations that maintained Alpha ratings were above 90% for all the restorative systems, in terms of anatomical form.

Marginal adaptation

For marginal adaptation criteria, 81.3% of the composite restorations were rated Alpha after 36 months (SBU/FZXT =58.1%; GB/GP =93.1%; OBX/HU = 93.5%). However, a significant change was observed for the SBU/FZXT group and two restorations failed at 36 months (p < .05). Unlike the GB/GP and OBX/HU groups, their marginal adaptation variations were not significant after 36 months of clinical service (p > .05), though two restorations, 1 GB/GP and 1 OBX/HU, with marginal fracture were seen at 12 and 36 months respectively. A statistically significant difference between the groups (p < 0.05) was observed, from 6 to 36 months.

Colour match

In terms of colour match, no change was recorded for any restoration from BL to 6 months. In the subsequent follow-ups, at 12 and 36 months, colour change was observed in Filtek Z350 XT and G-aenial Posterior composite restorations (SBU/FZXT and GB/GP groups) and was significant for only the G-aenial Posterior composite as 1 restoration had an obvious colour mismatch (p < .05). The Herculite Ultra restorations had no changes in colour, therefore, maintained their ratings after 36 months. In an intra group comparison, the difference between the three groups was not statistically significant at any of the recalls (p > .05) and restorations maintaining their alpha ratings were 87.1% for SBU/FZXT, 89.7% GB/GP and 90.3% OBX/HU groups.

Marginal discoloration

Marginal discoloration was seen in 14 restorations and distributed as follows; 29% SBU/FZXT, 10.3% GB/GP and 3.2% OBX/HU. Superficial staining appeared first at 6 months. The numbers of restorations with stains increased significantly for the group SBU/FZXT only (p < .05). In the GB/GP group, staining was registered at 6 and 12 months but then remained the same till 36 months. In the OBX/HU group marginal staining was first seen after 12 months, followed by a minor decrease in number of restorations showing marginal discoloration after 36 months due to patient loss. The restorations in groups GB/GP and OBX/HU performed similarly but there was a significant difference between them and the SBU/FZXT group at the 36 months evaluation (p < .05).

Surface texture

During the 36 months evaluation period, the composite restorations in the OBX/HU group, maintained an excellent surface texture (100%), unlike the SBU/FZXT and GB/GP restorations. In the SBU/FZXT group, a change in surface texture was observed and was statistically significant (p < 0.05) and 87.1% of the restorations maintained a good surface texture. A slight decrease was observed for the GB/GP composite restorations (89.3%), at the 6 and 12 months recalls but was statistically insignificant (p > .05). Furthermore, there was a statistically significant difference between the three groups at all the recalls (p < .05).

Secondary caries

During the 36 months, there was no sign of secondary caries in any of the restored teeth in the OBX/HU group and 100% of the restorations were rated Alpha. Recurrent caries was detected as early as 6 months in one (2.2%) GB/GP restoration followed by another one (4.3%) at 12 months and none were detected at 36 months. In the SBU/FZXT group, recurrent caries was detected in one restoration (2.2%) only at 12 months recall. In general, there was no statistically significant difference between the three groups from baseline to 36 months (p > .05) and caries free restorations, rated Alpha were more than 96%.

Discussion

Randomized clinical trials are fundamental in assessing the clinical performance of restorative materials. These materials are exposed to the variable conditions of the oral cavity. Therefore, clinical trials are preferred over laboratory tests. This study provides significant scientific data on the behaviour of different resin composites bonded with self-etch adhesives. They were all applied in SE mode. Considering the results obtained, the null hypothesis was rejected, as significant differences in performance were observed between the three restorative systems. The poorest clinical outcome was seen for the marginal adaptation parameter, and SBU/FZXT restorations presented the most significant marginal deteriorations, where only 58.1% of their restorations maintained Alpha ratings after 36 months. Failure due to marginal fractures were seen in four (2.9%) restorations. They occurred in class II restorations at the cavity margins. The first marginal fracture was seen at 6 months, in one GB/GP restoration (Figure 4). Subsequently, two SBU/FZXT and one OBX/HU marginal fractures occurred after 36 months. Restorations that failed earlier in the study were not registered, as the patients did not attend the final recall (Table 7). Individuals enrolled in this study did not have any parafunctional habits according to the selection criteria. All of the restorations were in contact with natural opposing dentition, but most of the occlusal contacts were located at the restoration margins, which could have increased the fracture incidence. Moreover, overfilling the cavity and inadequately assessing the occlusion increased stress concentration which resulted in premature failure [19].
Figure 4.

Tooth 24 OD (GB/GP) Marginal fracture at 6 months.

Marginal discolorations were seen in the three groups (SBU/FZXT, GB/GP and OBX/HU). The staining was superficial and located both occlusal and proximal at the buccal and lingual wall perimeter of Class II restorations, as shown in Figures 2 and 3. Marginal discoloration was more frequently observed in the SBU/FZXT composite restorations. In general, marginal discrepancies occurred more often in restorations bonded with self-etch adhesives. They form weak enamel bonds that promote debonding at restoration margins. This facilitated the entry of contaminants, resulting in marginal discolorations, which can explain our findings [7,9,10,14,20-22]. Ruschel et al., reported that the clinical performance of universal adhesives was independent of the application mode [23]. Conversely, in another study, poor marginal adaptations and increased marginal discolorations were observed only when the universal adhesives were applied in SE mode [24]. Variations can be encountered between materials in the same class of adhesives as their behaviour is product-dependent [25]. Studies confirmed that, selective enamel etching with phosphoric acid improved the effectiveness of mild SE and universal adhesives [13,26]. It must be noted that, when the present study was designed and performed the selective enamel etching technique was not yet recommended as a potential solution to improve the enamel bond. Therefore, the adhesives in the restorative systems tested were all applied in SE mode. According to the manufacturer, the pH of Scotchbond Universal is 2.7 and that of Optibond XTR and of G-aenial Bond are 2.4 and 1.5 respectively. Thus, when SE mode was used, restorations bonded with G-aenial Bond were expected to have a superior marginal adaptation compared to the universal adhesive and the two-step self-etch adhesive. The lower the pH of the adhesive, the more efficient is the selective enamel etching [7]. Conversely, in this study, the OBX/HU group with the OptiBond XTR adhesive performed better for all evaluated parameters, especially for the marginal adaptation. These results can be partly explained by the use of this particular two-step self-etch adhesive. OptiBond XTR consists of a separate hydrophobic component and contains a GPDM monomer, which can etch the enamel efficiently. For these reasons, OptiBond XTR achieved comparable bond strength to E&R adhesives, which adds to their overall success [27]. Unlike, the OptiBond XTR adhesive, Scotchbond Universal and G-aenial Bond adhesive systems have all their components combined. This creates instability and increases solubility, thus, reducing their mechanical properties [28-31]. In line with our results, a recent systemic review and meta-analysis reported that the one-step adhesive system exhibited lower bond strength than the two-step or three-step bonding systems after 1-year evaluation [32]. Another study by Perdigão et al., showed that one-step self-etch adhesives had significant inferior marginal integrity, colour match, surface texture, and occlusal function than the two-step etch-and-rinse adhesive systems [33]. Other studies with opposing results did not report any significant differences in the performance between the two-step SE OptiBond XTR adhesive and one-step SE All-Bond Universal adhesive in class II restorations [13]. The Scotchbond Universal adhesive contains 10-MDP (10-methacryloyloxydecyl dihydrogen phosphate) functional monomer, which imparts this adhesive its versatility [9,14,34]. It also contains HEMA (2-hydroxyethyl methacrylate) which facilitates the attraction of water from the dentinal tubules and the dissolution of the acidic monomers. Thus, their etching abilities are affected, resulting in a defective adhesion to enamel, which partly explains the poor performance of the Scotchbond universal adhesive [35]. Previous studies have reported no significant difference in the clinical behaviour of resin composites bonded with universal adhesives in any mode [36,37]. So far, mild SE adhesives and universal adhesives have proven to be clinically effective [7,38]. However, oversimplification of the adhesive systems and clinical procedures can compromise the clinical outcome. For this reason, more clinical studies are required to gain a better understanding on the performance of different marketed products.
Figure 2.

(a) Tooth 15 MOD (SBU/FZXT) preoperative. (b) Tooth 15 MOD (SBU/FZXT) at Baseline. (c) Tooth 15 MOD (SBU/FZXT) at 6 months. (d) Tooth 15 MOD (SBU/FZXT) at 12 months. (e) Tooth 15 MOD (SBU/FZXT) at 36 months.

Figure 3.

Tooth 14 OD (SBU/FZXT) superficial marginal discoloration at 36 months.

(a) Tooth 15 MOD (SBU/FZXT) preoperative. (b) Tooth 15 MOD (SBU/FZXT) at Baseline. (c) Tooth 15 MOD (SBU/FZXT) at 6 months. (d) Tooth 15 MOD (SBU/FZXT) at 12 months. (e) Tooth 15 MOD (SBU/FZXT) at 36 months. Tooth 14 OD (SBU/FZXT) superficial marginal discoloration at 36 months. Tooth 24 OD (GB/GP) Marginal fracture at 6 months. Besides the adhesive system used, other factors that affect restoration performance are composite-related. A major problem with resin composites is the polymerization shrinkage. This phenomenon, has significant implications on the long-term performance of restorations. which can lead to poor marginal adaptation, marginal discolorations, fractures, microleakage and recurrent caries, as seen in this study [39]. The composites used have comparable percentages of fillers by volume: Filtek Z350 XT (63.3%), G-aenial Posterior (65%) and Herculite Ultra (61%). Hence, similarity in properties and clinical behaviour was predicted [40]. Surface roughness was detected in some nanofilled Filtek Z350 XT resin composite restorations in the SBU/FZXT group and in the microhybrid G-aenial Posterior resin composite restorations in the GB/GP group but was statistically significant only for SBU/FZXT restorations. The finishing and polishing procedures are most likely the reason behind surface roughness, as two restorations were rated bravo at baseline. In previous studies, surface irregularity was frequently seen in Filtek Z350 XT restorations [41,42]. Additionally, the type of resin matrix, fillers and degree of conversion can influence the surface texture of the restorations [43]. A rough surface texture causes composite pigmentation from food intake, consequently colour mismatch with the adjacent teeth is seen in some restorations. While many clinical studies used NCCLs, the present study used class I and II lesions, that are stress-bearing posterior cavities and are frequently restored, for a better understanding of the restorative systems performance [36]. The C-factor is higher for class I cavities, yet failure occurred only in class II cavities and particularly at the gingival margins [44]. In this study, the gingival margins were mostly located in dentin with insufficient enamel, hence establishing a good bond strength at this region is important to avoid gap formation [44]. Therefore, the location of restoration margins can impact marginal integrity [45]. Besides marginal fracture, secondary caries was also a common reason of restoration failure [14]. It was detected as early as 6 months for a GB/GP restoration. Possible reasons could be that primary caries were not completely removed or that the patient presented bad oral hygiene, which may have increased the risk of recurrent caries [46]. Despite the strength of our study in using three different restorative systems which were evaluated clinically for 3 years, the current findings should be seen in the light of the following limitations: the modified USPHS criteria was employed as examiners were familiar with it and have used it before. However, its insensitivity when compared to the FDI evaluation criteria may have given a false impression of good performance in some cases leading to inaccurate results. Further follow-ups are required, as longer clinical trials can distinguish the restoration flaws more precisely, irrespective of the evaluation system used [15]. In conclusion, the three restorative systems have comparable clinical effectiveness and success rates. Except for marginal integrity where restorations bonded with the universal adhesive and one-step self-etch adhesive had inferior marginal adaptations than the restorations bonded with the two-step self-etch adhesive. When comparing the parameters directly influenced by the type of composite used, such as anatomical form, colour match and surface texture, results were similar for the nanofilled, nanohybrid and microhybrid resin composites.
  46 in total

1.  Bonding effectiveness of two contemporary self-etch adhesives to enamel and dentin.

Authors:  Atsushi Mine; Jan De Munck; Marcio V Cardoso; Kirsten L Van Landuyt; André Poitevin; Takuo Kuboki; Yasuhiro Yoshida; Kazuomi Suzuki; Paul Lambrechts; Bart Van Meerbeek
Journal:  J Dent       Date:  2009-07-07       Impact factor: 4.379

2.  A new universal simplified adhesive: 36-Month randomized double-blind clinical trial.

Authors:  Alessandro D Loguercio; Eloisa Andrade de Paula; Viviane Hass; Issis Luque-Martinez; Alessandra Reis; Jorge Perdigão
Journal:  J Dent       Date:  2015-07-06       Impact factor: 4.379

Review 3.  Universal adhesives: the next evolution in adhesive dentistry?

Authors:  Gary Alex
Journal:  Compend Contin Educ Dent       Date:  2015-01

4.  Posterior composite resins. Council on Dental Materials, Instruments, and Equipment.

Authors: 
Journal:  J Am Dent Assoc       Date:  1986-05       Impact factor: 3.634

5.  Three-year Randomized Clinical Study of a One-step Universal Adhesive and a Two-step Self-etch Adhesive in Class II Composite Restorations.

Authors:  Jan Wv van Dijken; Ulla Pallesen
Journal:  J Adhes Dent       Date:  2017       Impact factor: 2.359

Review 6.  Self-etch adhesive systems: a literature review.

Authors:  Marcelo Giannini; Patrícia Makishi; Ana Paula Almeida Ayres; Paulo Moreira Vermelho; Bruna Marin Fronza; Toru Nikaido; Junji Tagami
Journal:  Braz Dent J       Date:  2015 Jan-Feb

7.  Bonding Performance of Universal Adhesives: An Updated Systematic Review and Meta-Analysis.

Authors:  Carlos Enrique Cuevas-Suárez; Wellington Luiz de Oliveira da Rosa; Rafael Guerra Lund; Adriana Fernandes da Silva; Evandro Piva
Journal:  J Adhes Dent       Date:  2019       Impact factor: 2.359

8.  Nanofilled/nanohybrid and hybrid resin-based composite in patients with direct restorations in posterior teeth: A systematic review and meta-analysis.

Authors:  Bianca Medeiros Maran; Juliana Larocca de Geus; Mario Felipe Gutiérrez; Siegward Heintze; Chane Tardem; Marcos O Barceleiro; Alessandra Reis; Alessandro D Loguercio
Journal:  J Dent       Date:  2020-06-09       Impact factor: 4.379

9.  Clinical evaluation of resin-based composites in posterior restorations: a 3-year study.

Authors:  Çiğdem Çelik; Neslihan Arhun; Kivanc Yamanel
Journal:  Med Princ Pract       Date:  2014-08-12       Impact factor: 1.927

10.  One Year Clinical Evaluation of a Low Shrinkage Composite Compared with a Packable Composite Resin: A Randomized Clinical Trial.

Authors:  Razieh Hoseinifar; Elaheh Mortazavi-Lahijani; Hassan Mollahassani; Ahmad Ghaderi
Journal:  J Dent (Tehran)       Date:  2017-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.