A photo-electrochemical aptasensor for the determination of severe acute respiratory syndrome coronavirus 2 receptor-binding domain by using graphitic carbon nitride-cadmium sulfide quantum dots nanocomposite.

Mahmoud Amouzadeh Tabrizi1, Leila Nazari2, Pablo Acedo1.   

Abstract

Herein, a photoelectrochemical aptasensor for the quantitive measurement of the severe acute respiratory syndrome coronavirus-2 receptor-binding domain (Sars-Cov-2 RBD) has been reported for the first time. For this purpose, first, graphitic carbon nitride and (gC3N4) and cadmium sulfide (CdS) quantum dots were fabricated and characterized. After that, gC3N4 and CdS were mixed well. The fabricated nanomaterials were characterized by scanning transmission electron microscopy. Then, the CdS QDs-gC3N4 nanocomposite was added to the solution containing chitosan as an amine-rich polymer to generate a Chitosan/CdS-gC3N4 nanocomposite. Subsequently, the surface of the ITO electrode was modified with Chitosan/CdS-gC3N4. After that, the amine-terminal aptamer probes were immobilized on the surface of the Chitosan/CdS QDs-gC3N4/ITO electrode by using glutaraldehyde as an amine-amine crosslinker. The electrochemical performances of the electrodes were studied using cyclic voltammetry (CV), electrochemical Impedance Spectroscopy (EIS), and photo-electrochemistry (PEC). The surface coverage of the immobilized aptamer probe was founded to be 26.2 pmol.cm-2. The obtained results demonstrated that the proposed photo-electrochemical aptasensor can be used for the measurement of Sars-Cov-2 RBD within 0.5-32.0 nM. The limit of detection (LOD) was obtained to be 0.12 nM (at 3σ/slope). The affinity of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO was also founded to be 3.4 nM by using Langmuir-typical adsorption systems. The proposed photo-electrochemical aptasensor was applied for the measurement of the spiked Sars-Cov-2 RBD in human saliva samples at two concentrations. The effect of the interfering biomaterials such as human immunoglobulin G human immunoglobulin A, human immunoglobulin M, and human serum albumin was also studied.
© 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptasensor; Cadmium sulfide quantum dots; Coronavirus disease 2019; Graphitic carbon nitride; Photo-electrochemical method; Syndrome coronavirus 2 receptor-bonding domain

Year:  2021        PMID: 34219971      PMCID: PMC8240452          DOI: 10.1016/j.snb.2021.130377

Source DB:  PubMed          Journal:  Sens Actuators B Chem        ISSN: 0925-4005            Impact factor:   7.460


Introduction

The coronavirus disease 2019 (COVID-19) that is caused by the severe acute respiratory syndrome coronavirus 2 (Sars-Cov-2 RBD) is a global healthcare challenge these days. Hence, there is an urgent need to fabricate a highly selective, sensitive, selective, and cost-effective device for the diagnosis of Sars-Cov-2 RBD. Since Sars-Cov-2 RBD is a dangerous virus and those who work on it can be get infected on COVID-19, the researchers prefer to measure the related biomaterials to the Sars-Cov-2 virus such as its RNA [1], nucleocapsid protein (Np) [2,3], spike protein [4], and receptor-binding domain (Sars-Cov-2 RBD) [5] for its detection. By now, various methods have been reported for the diagnosing of biomaterials related to Sars-Cov-2 such as immunosensor [4], clustered regularly interspaced short palindromic repeats (CRISPR) [6], reverse transcription-polymerase chain reaction (RT-PCR) [1], and fluorescent aptasensor [5]. However, these methods have several disadvantages such as unportable, high expensive, time-consuming, and require operators with a high level of experience. The electrochemical aptasensors are good candidates to solve these disadvantages. The electrochemical aptasensors are the type of biosensor where an aptamer probe is used as the bio-recognizer element on the surface of a working electrode [7]. The aptamer is an artificial antibody that binds to its target with high affinity and specificity [8]. As the target binds to the immobilized aptamer on the surface of the working electrode, the working electrode then converts the aptamer-target interaction into a diagnostic electrical signal [9]. Compared to antibodies, aptamers are about 10 times smaller [10]. Therefore, more aptamers can be immobilized on the surface of the transducer. Also, aptamers are cheaper and can be synthesized with several functional groups [7]. Up to now, several electrochemical aptasensors have been designed for the diagonalization of viruses such as hepatitis B, [11,12], hepatitis C [13], virion [14], murine norovirus [15], human immunodeficiency virus (HIV) [16] influenza H1N1 [17,18], and influenza H5N1 [19,20]. Photo-electrochemical (PEC) based-aptasensor is one of the highly sensitive electrochemical biosensors that can be used for the determination of biomarkers. In addition to the previously ennumerated advantages of aptasensors, the PEC-based aptasensors have several additional advantages such as low background noise, low cost, simple operation, fast response, wide dynamic response range, and good stability, making them good candidates to fabricate the point of care biosensors [21,22]. To the best of our knowledge, a photo-electrochemical aptasensor for the determination of the receptor-binding domain of Sars-Cov-2 RBD has not yet been reported. To fabricate a photo-electrochemical biosensor, photoactive materials such as quantum dots (QD) [[23], [24], [25], [26]], titanium dioxide (TiO2) [25,27], and graphitic carbon nitride (gC3N4) [27,28] have been used to convert photons to electrons and then generate the photo-current. Cadmium sulfide quantum dots (CdS QDs) are one of the well-liked semiconductor materials that has been used for the fabrication of the photo-electrochemical-based biosensor because of its visible light activity and narrow band gap (2.4 eV) between the valence band and conduction band. However, the high recombination rate of photo-generated electrons and holes is its biggest disadvantage. To solve that, CdS QDs must be mixed with a second photo-active material that its band gap can overlap with the band gap of CdS QDs very well, separating the photo-generated electrons and holes each other. gC3N4 with a visible-light-driven band gap of 2.69 eV is a great candidate to solve this problem. Furthermore, gC3N4 has several advantages such as non-hazardous, cheap, metal-free, two-dimensional π-conjugated nanosheet, good chemical and thermal stability, and good electrical and optical properties, high-performance photo-activity and photo-stability [29,30]. In this study, CdS QDs and gC3N4 as photo-active materials, ascorbic acid as an electron donor molecule, chitosan as a binder, and an amine-terminal aptamer as a bio-recognizer have been used for the fabrication of the photo-electrochemical aptasensor. The results clearly display that the proposed aptasensor (Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode) can detect SARS-CoV-2 RBD in human saliva samples. The Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode revealed outstanding analytical performance in terms of dynamic response range, low detection limit, selectivity, sensitivity, and stability. The affinity of the proposed aptasensor to Sars-Cov-2 RBD was much better (about 4 times) than the previous reported method [5]. The proposed aptasensor is not only cheaper than the immunosensors that have been reported for diagnosing COVID-19 but also it has high sensitivity, low cost, and a portable device compared to the fluorescence apta-assay that has been reported before. Therefore, it has a great potential to be a point-of-care device to recognize COVID-19.

Experimental

Reagents and chemicals

The aptamer with the following sequences was obtained from Nzytech: 5′-NH2-(CH2)6- CAG CAC CGA CCT TGT GCT TTG GGA GTG CTG GTC CAA GGG CGT TAA TGG ACA-3′ [5]. Potassium hexacyanoferrate (III) (K3[Fe(CN)6]), potassium hexacyanoferrate (II) (K4[Fe(CN)6]), potassium chloride (KCl), ascorbic acid (AA), phosphoric acid (H3PO4), potassium hydroxide (KOH), melamine, cadmium chloride (CdCl2), sodium sulfide (Na2S), thioglycolic acid (TGA), and isopropanol alcohol were purchased from Merck. Severe acute respiratory syndrome coronavirus 2 receptor-binding domain (Sars-Cov-2 RBD), glutaraldehyde, chitosan, 6-amino-1-hexanol, and indium tin oxide (ITO) on the polyethylene terephthalate substrate were obtained from Sigma-Aldrich. Deionized (DI) water (18.6 MΩ) was used throughout.

Fabrication of nanomaterials

CdS QDs [26] and gC3N4 [27] have been fabricated according to our previous research work. Briefly, 2.0 g of melamine powder was transferred into an oven and the temperature of the oven was then increased to 520 °C for 4.0 h under argon conditions with a ramp rate of about 3 °C/min. Finally, gC3N4 was grounded in amortar with a pestle for 10 min. The yellow fine powder of gC3N4 was then dispersed in 1 mL of isopropanol alcohol in an ultrasonic agitation for 2 h to achieve a well-dispersed suspension. gC3N4 powder was then centrifuged, washed with isopropanol alcohol, re-dispersed in an ultrasonic agitation, and centrifuged again. This process was repeated 10 times to reach a thin layer nano-sheet of gC3N4. Finally, the obtained fine powder was dried at 60 °C. To fabricate CdS QDs, 1.3 mL of 0.15 M thioglycolic acid solution and 80.0 mL of 0.001 M CdCl2 solution were mixed in a round bottom flask. After that, 3.0 mL of 0.1 M NaOH was added gradually into the above solution to reach the pH value of the solution to 8.0. Subsequently, nitrogen gas was then purged through the above solution for 30 min. 20.0 mL of 0.002 M of Na2S was added into the flask and the mixture was allowed to react for 30 min at room temperature under a nitrogen gas atmosphere. Finally, CdS QDs powder was centrifuged, washed with ethanol, re-dispersed in ethanol and centrifuged several times, and dried at 60 °C. To fabricate CdS QDs-gC3N4 nanocomposite, 5 mg of gC3N4 and 1 mg of CdS QDs were added in 10 mL DI water and mixed together by using ultrasound for 2 h. The obtained nanocomposite was characterized by Energy-dispersive X-ray spectroscopy (EDX), and X-ray powder diffraction (XRD) (Fig. S2). The EDX result (Fig.S2A) specified that the composite contains nitrogen, carbon, cadmium, and sulfide elements. XRD analysis of CdS QDs-gC3N4 was also obtained (Fig.S2B). As shown, a strong peak about at 27° related to gC3N4 and two small peaked related to CdS QDs at about 45° and 53° are seen [31]. These results confirmed that CdS QDs and gC3N4 were mixed together.

Fabrication of the aptasensor

1 mL of chitosan solution (0.5 wt %) was added to the solution containing the CdS QDs-gC3N4 nanocmposites and ultrasonicated for 2 h. After that, 5.0 μL of Chitosan/CdS QDs-gC3N4 solution was dropped onto the surface of the ITO electrode (2 mm) and allowed to dry at room temperature. Then, 6 μL of 2.5 % glutaraldehyde solution was cast on the surface of the Chitosan/CdS QDs-gC3N4/ITO electrode to attach to the amine groups of chitosan for 45 min. Glutaraldehyde acted as a cross-linker to attach amino-terminal aptamer probes to amine groups of chitosan via shift base interaction between the aldehyde groups of glutaraldehyde and amine groups [32]. The surface coverage of the aptamer (Гaptamer) was founded to be 26.2 pmol.cm−2 or 1.58 × 1013 molecules. cm-2. The details of the calculation of the Гaptamer are mention in the supplementary data (Fig. S1). Then, the electrode was rinsed with 0.1 M phosphate buffer (PB, pH 7.4) solution. Subsequently, the electrode was deep in 0.5 mg/mL of aptamer solution (0.1 M PB, pH 7.4) for 4 h at 4 °C to attach the amine terminal aptamer to the surface of the Chitosan/CdS QDs-gC3N4/ITO electrode. The electrode was then washed with 0.1 M PB (pH 7.4) solution to remove the unattached aptamer probes. After that, the fabricated aptasensor was immersed in 0.1 M PB (pH 7.4) solution containing 0.1 M of 6-amino-1-hexanol for 1.0 h at room temperature to block non-specific sites. Finally, the fabricated aptasensor was washed with 0.1 M PB (pH 7.4) solution and kept in a refrigerator (4 °C) when not in use. Fig. 1 shows the schematic illustration of the proposed aptasensor (Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode) fabrication.
Fig. 1

The schematic illustration for fabrication of the aptasensor.

The schematic illustration for fabrication of the aptasensor.

Measurement procedure and the mechanism of PEC based-biosensor

During the measurement procedure, different concentration of Sars-Cov-2 RBD was dropped on the surface of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to interact with the aptamer probe for 40 min. After that, the aptasensor was rinsed with 0.1 M PB solution (pH 7.4) to wash away any loosely interacted Sars-Cov-2 RBD from the surface of aptasensor. Finally, the aptasensor was dipped in the measurement cell 0.1 M PB containing 0.1 M AA as an electron donor molecule to photo-excitable nanocomposite (CdS QDs-gC3N4). As CdS QDs-gC3N4 on the surface of the aptasensor was irradiated with a xenon lamp, CdS QDs that have a narrow band gap were photo-excited, generating hole and electron. The generated electron can back to the valance band and then recombine with the hole or transfer to the conductance band of gC3N4. If it recombines with a hole, the photocurrent won't be generated. To avoid that, the photo-generated electron should be transferred anyhow. For this purpose, the photo-excitable nanomaterial (CdS QDs) must be mixed with another photo-excitable one whose band gap (the gap between the conduction band and valence band) is larger than the first one but close to it to overlap with each other. The band gap of gC3N4 is 2.7 ev that is close to the band gap of CdS QDs (2.4 ev). Therefore, the generated photo-electron will transfer from the conduction band of CdS QD to the conduction band of gC3N4, avoiding the recombination of an electron with a hole. Besides that, gC3N4 can be photo-excited by a xenon lamp and generate a hole and electrode. The transferred electron from the conduction band of CdS QDs to the conduction band of gC3N4 as well as the photo-generated electron from gC3N4 transferred to the ITO electrode, generating photo-current. To have a stable photocurrent, the holes on the valance bands should be scavenged. For this purpose, an electron-donor molecule like AA is used. During the scavenging holes, the holes from the valance band of g-C3N4 transferred to the valance band of CdS QDs. After that, the holes oxidized AA. Any limitation in the diffusion of AA to the surface of electrode modified with photo-excitable nanomaterials will increase the possibility of the recombination of holes and electrons and subsequently decrease the intensity of the photo-current. In the absence of Sars-Cov-2 RBD (Fig. 2 A), AA can reach the surface of the electrode via diffusion without any limitation. As Sars-Cov-2 RBD that has a high molecular weight (35 kDa) incubated with the immobilized aptamer probes on the surface of the electrode (Fig. 2B), the mass transfer limitation for AA increased. Because Sars-Cov-2 RBD hindered AA to scavenge the holes and subsequently, the possibility of the recombination of holes and electrons increased. Therefore, the photo-current of the aptasensor in the presence of Sars-Cov-2 RBD decreased. Fig. 2 demonstrates the PEC mechanism resonse of the proposed aptasensor before (A) and after (B) the incubation of Sars-Cov-2 RBD with aptamer probes.
Fig. 2

Schematic illustration of separation mechanism of photogenerated electron − hole pairs between g-C3N4 and CdS QD on the proposed aptasensor before (A) and after (B) the incubation of Sars-Cov-2 RBD with aptamer probes.

Schematic illustration of separation mechanism of photogenerated electron − hole pairs between g-C3N4 and CdS QD on the proposed aptasensor before (A) and after (B) the incubation of Sars-Cov-2 RBD with aptamer probes.

Results and discussion

The morphology characterization of nanomaterials

Fig. 3 shows the scanning transmission electron microscopy (STEM) images in high angle annular dark field (left) and bright field (right) for CdS QDs (A,B), gC3N4 (C,D), CdS QDs-gC3N4 (E,F).
Fig. 3

Scanning transmission electron microscopy (STEM) images in high angle annular dark (left) and bright fields (right) for CdS QD (A,B), gC3N4 (C,D), CdS QDs-gC3N4 (E,F).

Scanning transmission electron microscopy (STEM) images in high angle annular dark (left) and bright fields (right) for CdS QD (A,B), gC3N4 (C,D), CdS QDs-gC3N4 (E,F). As can be seen in Fig. 3.A and B, CdS QDs have a spherical shape with an average diameter of 2 ± 0.5 nm. Also, STEM images of gC3N4 (Fig. 3 C and D) show that it has a wrinkled nanosheet structure. After mixing gC3N4 with CdS QDs, the gC3N4 was decorated with CdS QD uniformly (Fig. 3 E and F). The obtained STEM images confirmed that the nanocomposites were prepared successfully.

Surface characterization of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode

The Aptamer/Chitosan/CdS QDs-gC3N4 /ITO electrode was characterized. Fig. 4 .A and B show the high-resolution scanning electron microscopy images (HR-SEM) obtained with a secondary electron detector and a backscattered electron detector (Fig. 4.A, B). As shown in Fig. 4.A, the surface of the electrode was decorated with the CdS QDs-gC3N4 nano-sheet composite, uniformly. Although due to the excess of a thin layer of chitosan and the immobilized aptamer probe, CdS QDs cannot be observed, but the image obtained with a backscattered electron detector (Fig. 4B) showed that the surface of the electrode was coated with CdS QDs-gC3N4. The atomic force microscopy image and the surface profiles of the aptasensor were shown in Fig. 4C and D, respectively. As it can be seen, the surface of the electrode was modified with a thin layer of CdS QDs-gC3N4 nano-composite. The thickness of the Aptamer/Chitosan/CdS QDs-gC3N4 was about 13.6 nm.
Fig. 4

HR-SEM images obtained with a secondary electron detector (A) and backscattered electron detector (B). The AFM image (C), and the surface profile (D) of the Aptamer/Chitosan/CdS-gC3N4/ITO.

HR-SEM images obtained with a secondary electron detector (A) and backscattered electron detector (B). The AFM image (C), and the surface profile (D) of the Aptamer/Chitosan/CdS-gC3N4/ITO. The Aptamer/Chitosan/CdS QDs-gC3N4/gC3N4 ITO electrode was also characterized with an infrared attenuated total reflectance (IR-ATR) spectroscopy (Fig.S3). As shown, a broad absorption band around 3300 cm−1 attributed to the −OH group stretching of chitosan, two small absorption bands at 2930 cm−1 and 2850 cm-1, attributed to the symmetric and asymmetric stretching of the −CH2, and −CH3 groups, an absorption band at 1640 cm-1 attributed to the vibration of the –C = O group of guanine or thymine, an absorption band at 1570 cm-1 attributed to the –NH group deforming vibrations of the imidazole ring (nucleotide bases), an absorption band at 1230 cm-1 attributed to the –PO2- group of aptamer, and, an absorption band at 1050 cm-1 attributed to the –C-O-P- sugar-phosphate chin of aptamer are clearly seen. It demonstrated that the aptamer probe was immobilized on the surface of the electrode, successfully.

Electrochemical properties of the electrodes

Cyclic voltammetry (CV) (A), electrochemical impedance spectroscopy (EIS) (B), and PEC (C) methods were used to prove the stepwise changes in the electrochemical properties of the electrode surface (Fig. 5 ). CV and EIS signals were recorded in 0.1 M PB (pH 7.4) solution containing 0.5 mM Fe(CN)6 3−/4− as an electrochemical probe. Also, PEC signals were recorded in 0.1 M PB (pH 7.4) solution containing 0.1 mM AA as an electron donor.
Fig. 5

CV (A) and EIS (B) for a ITO (a), Chitosan/CdS QDs-gC3N4 /ITO (b), Aptamer/Chitosan/CdS QDs-gC3N4/ITO (c), Sars-Cov-2 RBD/Aptamer/Chitosan/CdS QDs-gC3N4/ITO (d) electrodes in a solution containing 5.0 mM Fe(CN)63−/4− couple (1:1) and 0.1 M PB, pH 7.4. (C) The PEC response of ITO (a), Chitosan/CdS QDs-gC3N4/ITO (b), Aptamer/Chitosan/CdS QDs-gC3N4/ITO (c), and (d) Sars-Cov-2 RBD/Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrodes in solution containing 0.1 mM AA and 0.1 M PB, pH 7.4. The bias potential for EIS is 0.23 V. In inset of Fig. 5.B, there is an equivalent electric circuit compatible with the Nyquist diagram. Rs: solution resistance, Ret: electron transfer resistance, Cdl: double layer capacitance, Zw: Warburg impedance. Ac amplitude was 10 mV, and frequency range was 100 kHz -0.1 Hz. Applied potential for PEC measurement is +0.05 V.

CV (A) and EIS (B) for a ITO (a), Chitosan/CdS QDs-gC3N4 /ITO (b), Aptamer/Chitosan/CdS QDs-gC3N4/ITO (c), Sars-Cov-2 RBD/Aptamer/Chitosan/CdS QDs-gC3N4/ITO (d) electrodes in a solution containing 5.0 mM Fe(CN)63−/4− couple (1:1) and 0.1 M PB, pH 7.4. (C) The PEC response of ITO (a), Chitosan/CdS QDs-gC3N4/ITO (b), Aptamer/Chitosan/CdS QDs-gC3N4/ITO (c), and (d) Sars-Cov-2 RBD/Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrodes in solution containing 0.1 mM AA and 0.1 M PB, pH 7.4. The bias potential for EIS is 0.23 V. In inset of Fig. 5.B, there is an equivalent electric circuit compatible with the Nyquist diagram. Rs: solution resistance, Ret: electron transfer resistance, Cdl: double layer capacitance, Zw: Warburg impedance. Ac amplitude was 10 mV, and frequency range was 100 kHz -0.1 Hz. Applied potential for PEC measurement is +0.05 V. Fig. 5A shows the cyclic voltammogram of electrodes. As shown in Fig. 5A (a), the ITO electrode showed a well-known one-electron redox couple for Fe(CN)63−/4−. After the modification of the ITO electrode with Chitosan/CdS-gC3N4 (b), the intensity of the redox couple increased, indicating that the Chitosan/CdS QDs-gC3N4 facilitated the electron transfer rate of Fe(CN)6 3−/4− probe on the electrode interface. After the immobilization of the aptamer on the surface of the Chitosan/CdS QDs-gC3N4 /ITO electrode (C), the intensity of the redox couple not only decreased but also the peak potential separation (ΔEp) of Fe(CN)6 3−/4− recorded by the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode (309 mV) increased compare to the Chitosan/CdS QDs-gC3N4/ITO electrode (139 mV). It indicates that the immobilized aptamer probes decreased the electron-transfer kinetics of Fe(CN)6 3−/4−. The reasonable explanation is that the negatively charged Fe(CN)6 3−/4− molecules were repulsed from the surface of the electrode by the negatively charged aptamer probes via the electrostatic interaction. After the incubation of Sars-Cov-2 RBD with aptamer on Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode (d), the intensity of the signal decreased more and the ΔEp increased (360 mV). This is due to the mass-transfer limitation of Fe(CN)6 3−/4− to the electrode surface caused by the Sars-Cov-2 RBD that has a big size (MW∼35 kDa). Fig. 5B shows the EIS of ITO electrode (a), Chitosan/CdS QDs-gC3N4/ITO electrode (b), Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode (c), and SARS-Cov-2 RBD/Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode (d). As can be seen, the diameter of the semicircles in a Nyquist plot of the EIS that shows the electron transfer resistance (Ret) decreased from 6105 Ω to 3765 Ω as the ITO electrode (a) was modified with Chitosan/CdS-gC3N4 (b). It indicates that the Chitosan/CdS QDs-gC3N4 nano-composite facilitated the rate of electron transfer. However, the Ret of the electrode increased to 11,200 Ω (c) as aptamer probes were immobilized on CdS QDs-gC3N4/ITO electrode. The Ret of the electrode increased to 17,628 Ω (d) as Sars-Cov-2 RBD (3 nM) interacted with the immobilized aptamer on the surface of the electrode. All these results demonstrated that the surface property of the electrode has been changed after each modification step. Fig. 5C shows the PEC responses of the ITO electrode (a), Chitosan/CdS QDs-gC3N4/ITO electrode (b), Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode (c), and Sars-Cov-2 RBD /Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode (d) in 0.1 M PB (pH 7.5) solution containing 0.1 mM AA. As shown, the ITO electrode did not show any PEC signal. After the modification of the ITO electrode with Chitosan/CdS QDs-gC3N4, the recorded PEC signal dramatically increased, verifying that the Chitosan/CdS QDs-gC3N4 /ITO electrode is a suitable electrode for obtaining the PEC signal. After the immobilization of the aptamer probes, the PEC signal decreased due to the diffusion limitation of the electron donor molecule (AA) to the ITO electrode surface coated with a photoactive nanocomposite (CdS QDs-gC3N4) and the electrostatic repulsion interaction between negatively charged AA and negatively charged aptamer probes. As SARS-Cov-2 RBD (3 nM) interacted with the immobilized aptamer on the surface of the electrode, the PEC signal decreased even more than before. The reasonable explanation is that the attachment of a high-molecular-weight protein like SARS-Cov-2 RBD [33] to the aptamer hindered the diffusion of electron donor (AA) to the electrode surface. The effect of the incubation time on the response of the proposed aptasensor was also studied. As it can be seen in Fig. 6 A, the response of the proposed aptasensor to 3 nM of SARS-Cov-2 RBD decreased as the incubation time increased up to 40 min and after that, the signal did not change anymore. The reasonable explanation is that the interaction of the immobilized aptamers on the surface of the electrode and SARS-Cov-2 RBD reached the saturation level.
Fig. 6

The effect of the incubation time on the response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to 3 nM Sars-Cov-2 RBD (A). The effect of the concentration of the immobilized aptamer on the response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to 3 nM SARS-Cov-2 RBD (B). Applied potential: +0.05 V.

The effect of the incubation time on the response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to 3 nM Sars-Cov-2 RBD (A). The effect of the concentration of the immobilized aptamer on the response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to 3 nM SARS-Cov-2 RBD (B). Applied potential: +0.05 V. The concentration of the amino-terminal aptamer was also optimized (Fig. 6B). As it can be seen, the sensitivity of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to 3 nM Sars-Cov-2 RBD during 40 min increased from 0.1 mg/mL to 0.5 mg/mL and then decreased as it reached to 0.75 mg/mL. The reasonable explanation is that the negatively charged aptamers repelled each other in the high concentration of aptamer [34]. Therefore, 0.5 mg/mL of amino-terminal aptamer and 40 min incubation time between the aptamer and Sars-Cov-2 RBD were selected as optimum conditions.

Detection of Sars-Cov-2 RBD and study the stability, selectivity, and reproducibility of the proposed aptasensor

Fig. 7A and B show the PEC response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to the various concentrations of Sars-Cov-2 RBD (A) and the associated calibration curve (B), respectively. As shown in Fig. 7A, the intensity of the photocurrent kept decreasing as the concentration in the measurement solution of Sars-Cov-2 RBD increased. Fig.7B shows that the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode has a good linear relationship with the logarithm of the concentration of Sars-Cov-2 RBD in the range of 0.5 nM to 32 nM. The linear regression equation of the calibration curve is expressed as ΔI (μA) = -0.54 log C[Sars-Cov-2 RBD] (nM) + 1.04 with a correlation coefficient of R2 = 0.995 (n = 7). The limit of detection (LOD) was calculated to be 0.12 nM (3σ/S), where σ a is the standard deviation of the blank measurements and S is the slope. The denoted error bars in Fig. 7B were calculated from the standard deviation for five measurements.
Fig. 7

PEC response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to the different concentrations of Sars-Cov-2 RBD (A). The plot of PEC signal versus the logarithm of SARS-Cov-2 RBD concentration (0.5, 1, 3, 6, 8, 16, and 32 nM) (B). The selectivity of the Aptamer/Chitosan/CdS-gC3N4/ITO electrode to 1 nM Sars-Cov-2 RBD in the absence (a) and presence of 5 times excess of HIgG (b), HSA (c), HIgA (d), and HIgM antigens (e). The stability of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode before (a) and after (b) 3 weeks (D). Applied potential: +0.05 V.

PEC response of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to the different concentrations of Sars-Cov-2 RBD (A). The plot of PEC signal versus the logarithm of SARS-Cov-2 RBD concentration (0.5, 1, 3, 6, 8, 16, and 32 nM) (B). The selectivity of the Aptamer/Chitosan/CdS-gC3N4/ITO electrode to 1 nM Sars-Cov-2 RBD in the absence (a) and presence of 5 times excess of HIgG (b), HSA (c), HIgA (d), and HIgM antigens (e). The stability of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode before (a) and after (b) 3 weeks (D). Applied potential: +0.05 V. The values of the dissociation constant (Kd) that shows the affinity of the proposed aptasensor to the target was also calculated using the Langmuir-typical adsorption systems (Fig.S4): [35] The value of Kd (1/KL) was funded to be 3.4 nM that was lower than the previous apta-assay method [5], indicating the high affinity of the proposed aptasensor to Sars-Cov-2 RBD. In this equation, Imax is the maximum number of binding sites, and KL is the Langmuir isotherm constant. Fig. 7C shows the interfering effect of HIgG (a), HSA (b), HIgA (c), and HIgM (d) antigens (5-fold quantities) on the PEC signal of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode to 1 nM Sars-Cov-2 RBD. As shown, no interference was observed, indicating the high selectivity of the proposed aptasensor. The stability of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode has been studied (Fig. 7 D). After 3 weeks, the PEC signal of the aptasensor retained 96 % of its original response, suggesting good stability of the proposed aptasensor. Also, the obtained results showed that the signals of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode were stable after 10-times repetitions (Fig. S5). The reproducibility was also studied for determinations of 0.1 nM of Sars-Cov-2 RBD with six different aptasensors. The relative standard deviation (RSD) was calculated to be 5.8 %.

Analytical application of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode

The applicability of the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode was also studied. To consider that, the proposed aptasensor was used for the measurement of 0.1 nM and 16 nM Sars-Cov-2 RBD in two different normal human saliva samples (Fig.S6). 1 mL of the first normal human saliva sample was diluted with 0.2 M PB solution containing 2 nM Sars-Cov-2 RBD, and 0.2 mM AA, and 1 mL of the sencond normal human saliva sample was dilutied with 0.2 M PB solution containing 32 nM Sars-Cov-2 RBD, and 0.2 mM AA. The Sars-Cov-2 RBD concentration in the normal human saliva samples were estimated by using Fig. 7B. The recovery of the analysis was obtained to be about 95.7 % for first sample 96.4 % for the second sample. The values were determined by the standard method that was used for florescence apta-assay of SARS-Cov-2 RBD [5]. It indicated that the Aptamer/Chitosan/CdS QDs-gC3N4/ITO electrode has outstanding applicability for the diagnosis of COVID-19.

Conclusions

In summary, a photoelectrochemical aptasensor for the measurement of SARS-Cov-2 RBD has been developed by using CdS QDs-gC3N4 entrapped in chitosan as a photoactive nanocomposite. The response mechanism of the aptasensor is based on the change in the photoactive property of the surface of the ITO electrode modified with the Aptamer/Chitosan/CdS QDs-gC3N4. After the interaction of Sars-Cov-2 RBD with the immobilized aptamer probe on the surface of the electrode, the mass transfer limitation for AA as an electron donor molecule to the photoactive nanocomposite (CdS QDs-gC3N4) increased. Consequently, the intensity of the photo-current decreased. Therefore, the proposed aptasensor is considered as a signal-off-based aptasensor. The proposed aptasensor could be used for the determination of Sars-Cov-2 RBD in the dynamic range of 0.5−32 nM with a LOD of 0.12 nM. The aptasensor showed good selectivity in the presence of HIgG, HIgA, HIgM, and HSA.

CRediT authorship contribution statement

Mahmoud Amouzadeh Tabrizi: Supervision, Writing - review & editing, Resources, Project administration, Funding acquisition, Conceptualization, Methodology, Formal analysis, Investigation, Writing - original draft. Leila Nazari: Formal analysis. Pablo Acedo: Formal analysis, Writing - review & editing.

Declaration of Competing Interest

The authors declare that they have no known competing financial interestsor personal relationships that could have appeared to influence the work reported in this paper.
  26 in total

1.  Highly Sensitive Photoelectrochemical Biosensor Based on Quantum Dots Sensitizing Bi2Te3 Nanosheets and DNA-Amplifying Strategies.

Authors:  Yali Yuan; Tao Hu; Xia Zhong; Minghui Zhu; Yaqin Chai; Ruo Yuan
Journal:  ACS Appl Mater Interfaces       Date:  2020-05-06       Impact factor: 9.229

Review 2.  A review: Recent advances in ultrasensitive and highly specific recognition aptasensors with various detection strategies.

Authors:  Shu-Rong Yan; Mohammad Mehdi Foroughi; Mohadeseh Safaei; Shohreh Jahani; Nasser Ebrahimpour; Fariba Borhani; Nadia Rezaei Zade Baravati; Zahra Aramesh-Boroujeni; Loke Kok Foong
Journal:  Int J Biol Macromol       Date:  2020-03-23       Impact factor: 6.953

3.  Discovery of sandwich type COVID-19 nucleocapsid protein DNA aptamers.

Authors:  Liyun Zhang; Xiaona Fang; Xingbo Liu; Huichao Ou; Haiyan Zhang; Jinjun Wang; Qian Li; Huanyi Cheng; Wenyi Zhang; Zhaofeng Luo
Journal:  Chem Commun (Camb)       Date:  2020-08-05       Impact factor: 6.222

4.  Effects of diamond-FET-based RNA aptamer sensing for detection of real sample of HIV-1 Tat protein.

Authors:  A Rahim Ruslinda; Kyosuke Tanabe; Shoji Ibori; Xianfen Wang; Hiroshi Kawarada
Journal:  Biosens Bioelectron       Date:  2012-08-21       Impact factor: 10.618

5.  Subtyping of influenza A H1N1 virus using a label-free electrochemical biosensor based on the DNA aptamer targeting the stem region of HA protein.

Authors:  Jyoti Bhardwaj; Narendra Chaudhary; Hajin Kim; Jaesung Jang
Journal:  Anal Chim Acta       Date:  2019-03-09       Impact factor: 6.558

6.  Amperometric bioaffinity sensing platform for avian influenza virus proteins with aptamer modified gold nanoparticles on carbon chips.

Authors:  Farhana Sharmin Diba; Suhee Kim; Hye Jin Lee
Journal:  Biosens Bioelectron       Date:  2015-05-09       Impact factor: 10.618

7.  A photoelectrochemical sandwich immunoassay for protein S100β, a biomarker for Alzheimer's disease, using an ITO electrode modified with a reduced graphene oxide-gold conjugate and CdS-labeled secondary antibody.

Authors:  Mahmoud Amouzadeh Tabrizi; Josep Ferré-Borrull; Pankaj Kapruwan; Lluis F Marsal
Journal:  Mikrochim Acta       Date:  2019-01-16       Impact factor: 5.833

8.  A photoelectrochemical aptasensor constructed with core-shell CuS-TiO2 heterostructure for detection of microcystin-LR.

Authors:  Yunfei Tang; Yun Chai; Xiaoqiang Liu; Lele Li; Liwei Yang; Peipei Liu; Yanmei Zhou; Huangxian Ju; Yunzhi Cheng
Journal:  Biosens Bioelectron       Date:  2018-06-05       Impact factor: 10.618

9.  Aptamer selection and application in multivalent binding-based electrical impedance detection of inactivated H1N1 virus.

Authors:  Chenjun Bai; Zhangwei Lu; Hua Jiang; Zihua Yang; Xuemei Liu; Hongmei Ding; Hui Li; Jie Dong; Aixue Huang; Tao Fang; Yongqiang Jiang; Lingling Zhu; Xinhui Lou; Shaohua Li; Ningsheng Shao
Journal:  Biosens Bioelectron       Date:  2018-03-22       Impact factor: 10.618

10.  Ultrasensitive norovirus detection using DNA aptasensor technology.

Authors:  Amanda Giamberardino; Mahmoud Labib; Eman M Hassan; Jason A Tetro; Susan Springthorpe; Syed A Sattar; Maxim V Berezovski; Maria C DeRosa
Journal:  PLoS One       Date:  2013-11-14       Impact factor: 3.240

View more
  12 in total

1.  An electrochemical membrane-based aptasensor for detection of severe acute respiratory syndrome coronavirus-2 receptor-binding domain.

Authors:  Mahmoud Amouzadeh Tabrizi; Pablo Acedo
Journal:  Appl Surf Sci       Date:  2022-05-30       Impact factor: 7.392

2.  Study on the genetic damage caused by cadmium sulfide quantum dots in human lymphocytes.

Authors:  Haiping Liu; Huajie Liu; Haiyan Liu; Duo Zhang; Qian Wang; Shuang Li; Yanhua Cao; Qingzhao Li
Journal:  Open Life Sci       Date:  2022-05-11       Impact factor: 1.311

Review 3.  Ultrasensitive Aptasensors for the Detection of Viruses Based on Opto-Electrochemical Readout Systems.

Authors:  Daphika S Dkhar; Rohini Kumari; Supratim Mahapatra; Rahul Kumar; Pranjal Chandra
Journal:  Biosensors (Basel)       Date:  2022-01-29

Review 4.  Development of the DNA-based biosensors for high performance in detection of molecular biomarkers: More rapid, sensitive, and universal.

Authors:  Qiong Wang; Jing Wang; Yan Huang; Yichen Du; Yi Zhang; Yunxi Cui; De-Ming Kong
Journal:  Biosens Bioelectron       Date:  2021-10-29       Impact factor: 10.618

Review 5.  Multifunctional carbon nanomaterials for diagnostic applications in infectious diseases and tumors.

Authors:  Yang He; Chenyan Hu; Zhijia Li; Chuan Wu; Yuanyuan Zeng; Cheng Peng
Journal:  Mater Today Bio       Date:  2022-03-05

Review 6.  Photoelectrochemical aptasensors for detection of viruses.

Authors:  Veronika Svitková; Kristína Konderíková; Katarína Nemčeková
Journal:  Monatsh Chem       Date:  2022-03-24       Impact factor: 1.451

7.  A Folding-Based Electrochemical Aptasensor for the Single-Step Detection of the SARS-CoV-2 Spike Protein.

Authors:  Federica Curti; Simone Fortunati; Wolfgang Knoll; Marco Giannetto; Roberto Corradini; Alessandro Bertucci; Maria Careri
Journal:  ACS Appl Mater Interfaces       Date:  2022-04-21       Impact factor: 10.383

Review 8.  Quantum dots against SARS-CoV-2: diagnostic and therapeutic potentials.

Authors:  Navid Rabiee; Sepideh Ahmadi; Ghazaleh Jamalipour Soufi; Ali Hekmatnia; Mehrdad Khatami; Yousef Fatahi; Siavash Iravani; Rajender S Varma
Journal:  J Chem Technol Biotechnol       Date:  2022-02-04       Impact factor: 3.709

Review 9.  Aptamers targeting SARS-COV-2: a promising tool to fight against COVID-19.

Authors:  Yang Zhang; Mario Juhas; Chun Kit Kwok
Journal:  Trends Biotechnol       Date:  2022-08-01       Impact factor: 21.942

10.  An Electrochemical Impedance Spectroscopy-Based Aptasensor for the Determination of SARS-CoV-2-RBD Using a Carbon Nanofiber-Gold Nanocomposite Modified Screen-Printed Electrode.

Authors:  Mahmoud Amouzadeh Tabrizi; Pablo Acedo
Journal:  Biosensors (Basel)       Date:  2022-02-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.