Literature DB >> 34214092

Spatial disinfection potential of slightly acidic electrolyzed water.

Midori Kurahashi1, Takaaki Ito2, Angelica Naka1.   

Abstract

Slightly acidic electrolyzed water (SAEW) was developed by Japanese companies over 20 years ago. SAEW has the advantage of potent sterilizing action while being relatively safe. This study evaluated the potential application of SAEW in spatial disinfection. Prior to experiments involving spatial spraying, the ability of SAEW to remove seven type of microorganisms that cause food poisoning was studied in vitro. Results indicated that free chlorine in SAEW, even at a low concentration (30 mg/L), was able to remove Cladosporium cladosporioides, a typical airborne fungus that degrades food, and spores such as Bacillus subtilis, a hardy bacterium. In an experiment involving spatial spraying, 3.43 log10 CFU/100 L of Staphylococcus epidermidis was sprayed in a room-sized space; the same space was then sprayed with SAEW. The number of settling microbes was measured and the sterilizing ability of SAEW was assessed. Results indicated that the concentration of S. epidermidis in the space was completely removed after 20 minutes of SAEW spraying. The above findings indicate that SAEW may be used to remove airborne microorganisms via spatial spraying.

Entities:  

Year:  2021        PMID: 34214092      PMCID: PMC8253431          DOI: 10.1371/journal.pone.0253595

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


1 Introduction

Hypochlorite-based and chlorine dioxide-based agents are widely used around the world as chlorine-based sanitizers. Commercially available sodium hypochlorite solutions have free available chlorine concentrations of 50,000–120,000 mg/L; this is typically diluted to 100–200 mg/L when used. Sodium hypochlorite solutions are inexpensive and relatively effective, so they have been used around the world for over 100 years. However, bromic acid can contaminate sodium hypochlorite solutions, as a by-product of the production process. Bromic acid is a chemical substance that recent research suggests is carcinogenic [1]. Moreover, certain interactions between sodium hypochlorite and organic matter can generate chloroform (a trihalomethane) [2], another chemical substance that is suspected of being carcinogenic [3]. A trade-off for the potent sterilizing action of chlorine dioxide is that the substance is extremely dangerous in its pure form, requiring a material safety data sheet (MSDS). Thus, chlorine dioxide is typically available as stabilized chlorine dioxide (actually “stabilized chlorite”). Stabilized chlorine dioxide is the general name given to a substance or mixture that generates chlorine dioxide rather than the actual name of a substance. Stabilized chlorine dioxide refers to any substance that is physically stable and adjusted to gradually release chlorine dioxide in accordance with environmental changes such as temperature and pH (the extent of release differs depending on the product). In addition, the potency of stabilized chlorine dioxide and pure chlorine dioxide differs vastly even at the same concentration. A vast variety of products is sold as stabilized chlorine dioxide, but the methods of stabilization vary depending on the product, so assessing their overall safety and effectiveness is difficult. In Japan, companies have developed products by electrolyzing a dilute hydrochloric acid solution in a diaphragm-less electrolytic cell and diluting with tap water to a pH of 5–6.5. This aqueous solution is used as a sterilizing solution. A major sterilizing component in slightly acidic electrolyzed water (SAEW) is hypochlorous acid (HOCl), this is different from the hypochlorous acid solution produced by mixing an acid with sodium hypochlorite. Japan’s Ministry of Health, Labor, and Welfare designated SAEW as a food additive sanitizer in 2002, and the Ministry of Agriculture, Forestry, and Fisheries and the Ministry of the Environment designated SAEW as a control agent in 2014. Thus, areas in which SAEW is used in Japan are expanding, rapidly gaining acceptance in the area of food sanitation in particular. One of SAEW’s potential applications may be spatial disinfection due to its safety and sterilizing capacity. Spatial disinfection with a conventional agent involves spraying in an unoccupied space or using protective equipment. The disinfected space generally requires proper ventilation afterwards. In contrast, SAEW has sterilizing action even at a low concentration. Its efficacy as disinfectant was measured in this research by directly applying SAEW on different types of bacteria and bacterial spores. Spatial disinfection can be performed spraying SAEW with free chlorine concentrations of 100 mg/L or lower and without concern for residual chlorine. There are numerous studies on the sterilizing action of electrolyzed water, but there are very few studies on the use of SAEW for indoor disinfection [4-6]. Given the emergence of multidrug-resistant microorganisms and the increased risk of infectious diseases due to climate change [7], the demand for disinfection of spaces such as food factories, hospitals, care facilities, kindergartens, and animal pens and coops is expected to continue growing in the future. The current study assessed disinfection when spraying SAEW in a space, and it discusses the potential for spatial disinfection with SAEW.

2 Materials and methods

2.1 Microbial culture and preparation of inocula

An in vitro experiment was performed with Bacillus cereus NBRC 13494, Bacillus subtilis NBRC 3134, Pseudomonas aeruginosa NBRC 13275, Salmonella enterica subsp. enterica NBRC 3313, Staphylococcus aureus subsp. aureus NBRC 12732, Cladosporium cladosporioides NBRC 6348, and Staphylococcus epidermidis NBRC 12993 from the NITE Biological Resource Center (NBRC, Japan) and Escherichia coli ATCC 43895 (serotype O157:H7, a verotoxin I and II-producing strain) from the American Type Culture Collection (ATCC, USA). B. cereus was cultured on nutrient agar PT2810 (Eiken Chemical Co.) and B. subtilis was cultured on soybean-casein digest agar PT8010 (Eiken Chemical Co.) at 35°C±1°C for 7–10 d. Each bacterium was then suspended in physiologic saline solution, heated to 70°C±1°C for 20 min to kill nutritive cells. Each suspension was centrifuged, the supernatant was removed, bacterial cells were suspended in physiologic saline solution, and the spore count was adjusted to about 108–109 CFU/mL to yield the bacterial spore solution. The bacterial spore solution was diluted with physiologic saline solution and adjusted to 107–108 CFU/mL to yield the test bacterial solution. E. coli, P. aeruginosa, S. enterica, S. aureus were each cultured on nutrient agar PT 1010 (Eiken Chemical Co.) at 35°C±1°C for 18–24 h. Each bacterium was then suspended in physiologic saline solution and the bacterial count was adjusted to 107–108 CFU/mL to yield the test bacterial solution. S. epidermidis was cultured in a brain heart infusion broth PT3025 (Eiken Chemical Co.) at 35°C±1°C for 18–24 h. The bacterial count was adjusted to 107−108 CFU/mL with a sterile phosphate buffer (phosphate-buffered saline, or PBS) to yield the test bacterial solution. C. cladosporioides was cultured on potato dextrose agar PT 2610 (Eiken Chemical Co.) at 25°C±1°C for 7–10 days. Spores were suspended in a 0.005% dioctyl sodium sulfosuccinate solution. The suspension was filtered through a non-woven fabric filter. The fungal count was adjusted to 107–108 CFU/mL to yield the test fungal solution. A spatial disinfection experiment was performed with S. epidermidis NBRC 12993 from the NITE Biological Resource Center (NBRC), Japan. The test bacterium was cultured in a brain heart infusion broth PT3025 (Eiken Chemical Co.) at 35°C±1°C for 18–24 h. The bacterial count was adjusted to 106 CFU/mL with a sterile phosphate buffer (phosphate-buffered saline, or PBS) to yield the test bacterial solution. One mL of PBS was added to 2 mL of the bacterial solution to create 3 mL of spray solution. S. epidermidis was the only microorganism selected for spatial disinfection experiments because it is a common bacterium present in the human skin and, thus, does not usually cause infections in non-compromised patients and does not require high level of biosafety laboratories.

2.2 Preparation of treatment solutions

Slightly acidic electrolyzed water (HOCL0.36 t, HOCL Inc.) was specifically prepared by Organo Food Tech, Saitama, Japan for the purpose of these experiments. The SAEW used in experiments involving pure cultures had an available chlorine concentration of 30 mg/L and a pH of 5.9. SAEW used in the spatial disinfection experiment had an available chlorine concentration of 41 mg/L and a pH of 6.0.

2.3 Effects of SAEW on pure cultures

Experiment on pure cultures was prepared by mixing 9.9 mL of SAEW with 0.1 mL of the test microbial solution. This test solution was stored at 20°C±1°C. After 15 s, 1 min, and 15 min, it was immediately diluted 10-fold with soybean-casein digest medium with polysorbate 80 & lecithin SCDLP “DAIGO” (Nihon Pharmaceutical Co.). Microorganisms in the test solution were counted using a medium for cultivation and isolation. The medium for cultivation and isolation was soybean-casein digest agar with polysorbate 80 & lecithin SCDLP “DAIGO” (Nihon Pharmaceutical Co.) for B. cereus, B. subtilis, E. coli, P. aeruginosa, S. enterica, S. aureus, and S. epidermidis. Each bacterium was then cultured at 35°C±1°C for 2 days using the pour plate method. The medium for cultivation and isolation was glucose peptone agar with lecithin & polysorbate 80 GPLP AGAR “DAIGO” (Nihon Pharmaceutical Co.) for C. cladosporioides. The fungus was cultured at 25°C±1°C for 7 days using the pour plate method. Similar testing was performed using purified water as a control, and viable microorganisms were counted at the start and after 15 min. All experiments were performed in triplicate.

2.4 Effects of indoor spraying of SAEW

Negative pressure was generated in a clean chamber with a volume of 26 m3 (length: 2.99 m, width: 3.96 m, height: 2.21 m), internal air was sampled with an air sampler (SAS Super ISO100, PBI, Milan, Italy), the purity of the air inside was measured, and air was determined to be sufficiently pure. S. epidermidis adjusted to 1×106 CFU/mL was mixed with PBS. Three mL of this mixture (2 mL of the bacterial solution+1 mL of PBS) was sprayed at a rate of 1 mL/min for 3 min from the spray nozzle of an ultrasonic humidifier AHD-012 (Shizuku Plus+, Apix International, Osaka, Japan) in a large clean chamber. A fan for bacterial dispersal was run for 1 min; once the air in the clean chamber was agitated, it was sampled. This served as 0 min. The ultrasonic humidifier was then run at 5.5 mL/min, and spraying of SAEW began. Air (100 L) was sampled with the air sampler every 10, 20, 30, and 40 min, and airborne bacteria were counted. Testing was similarly performed without running the ultrasonic humidifier and when spraying sterile water to serve as negative controls. This experiment was repeated three times.

2.5 Statistical analysis

All experiments were performed in triplicate. Microbial counts are the mean±standard deviation for individual samples. The obtained results were statistically assessed using Tukey’s honestly significant difference (HSD) test, with P < 0.05 considered to be statistically significant.

3 Results

3.1 Effects of SAEW on pure cultures

Results of in vitro experiment involving typical microorganisms that cause food poisoning are shown in Fig 1. Treatment of B. cereus (spores), a gram-positive bacillus that causes food to spoil, resulted in 1/10 of the original log10 CFU/mL after 60 sec. After 15 minutes, a logarithmic decrease of 4.9 was observed. Similarly, after B. subtilis (spores) was treated with SAEW, a logarithmic decrease of 5.0 or greater (log10 CFU/mL) was noted within 15 min. After E. coli (O157:H7), P. aeruginosa, and S. enterica, which are typical gram-negative bacteria that cause food poisoning, were treated with SAEW, a respective logarithmic (log10 CFU/mL) decrease of 5.5, 5.8 and 6.2 or greater was noted within 15 min. Treatment of S. aureus and S. epidermidis, gram-positive facultative anaerobic bacilli, with electrolyzed water resulted in logarithmic (log10 CFU/mL) decrease of 5.2 or greater and 5.4 or greater, respectively within 15 sec. After C. cladosporioides, a typical contaminating fungus, was treated with SAEW, a logarithmic decrease of 5.7 or greater (log10 CFU/mL) was noted within 60 sec.
Fig 1

Effects of SAEW on pure cultures (a) Bacillus cereus, (b) Bacillus subtilis, (c) Escherichia coli (O157:H7), (d) Pseudomonas aeruginosa, (e) Salmonella enterica subsp. enterica, (f) Staphylococcus aureus subsp. aureus, (g) Cladosporium cladosporioides, and (h) Staphylococcus epidermidis.

Effects of SAEW on pure cultures (a) Bacillus cereus, (b) Bacillus subtilis, (c) Escherichia coli (O157:H7), (d) Pseudomonas aeruginosa, (e) Salmonella enterica subsp. enterica, (f) Staphylococcus aureus subsp. aureus, (g) Cladosporium cladosporioides, and (h) Staphylococcus epidermidis.

3.2 Effects of indoor spraying of SAEW

To determine the microbe count, 100 L of air was sampled 5 times every 10 min, so a total of 500 L was sampled. That air was supplied from outside and passed through a HEPA filter. Thus, a correction for that amount would need to be made to achieve accuracy. However, since only 1.92% of the chamber volume was sampled, no correction was performed in this study. Fig 2 shows changes in the amount of airborne bacteria in the large clean chamber over time. Natural bacterial attenuation and humidity due to water spraying may impact bacterial concentration. Thus, gradual bacterial attenuation due to both, natural attenuation and water were also evaluated. After 20 minutes, the amount of the logarithmic decrease with natural attenuation was 0.54 log10 CFU/100 L, whereas the logarithmic decrease with sprayed water was 0.86 log10 CFU/100 L. Immediately after SAEW was sprayed, however, the bacterial count abruptly decreased, and it was below detection sensitivity after 20 min. The logarithmic decrease was 3.43 log10 CFU/100 L.
Fig 2

Bactericidal effect of slightly acidic electrolyzed water spray on airborne bacteria.

Test bacterium is dispersed by sprayed water, so the humidity in the chamber may impact the amount of the bacterium. In order to reduce the amount of moisture for a sprayed bacterium, an ultrasonic mister was used instead of a typical nebulizer. Changes in humidity in the large clean chamber under different conditions are shown in Fig 3. The chamber temperature during measurement was 24°C. Humidity under natural conditions was almost constant at 40%, but it increased from 40 to nearly 80% in 40 min when sterile water or SAEW was sprayed. Moreover, the effects of humidity on the amount of airborne bacteria can be ascertained by comparing Figs 2 and 3. Fig 2 shows how the bacterial count gradually decreased with natural attenuation and the spraying of sterile water but it markedly decreased abruptly with the spraying of SAEW. In other words, this experiment revealed that the effects of humidity on the amount of airborne bacteria are extremely low compared to the effects of SAEW on the reduction in the bacterial count.
Fig 3

Humidity inside the chamber.

4 Discussion

Besides sodium hypochlorite and chlorine dioxide, aqueous solutions obtained by electrolyzing a sodium chloride solution are also used as chlorine-based disinfectants. When a dilute sodium chloride solution is electrolyzed in an electrolytic cell with a diaphragm, a strongly acidic aqueous solution is generated in the anode chamber and a strongly alkaline aqueous solution is generated in the cathode chamber. Strongly acidic electrolyzed water (AEW) generated in the anode chamber has potent sterilizing action [8-13]. However, the sterilizing action of AEW disappears in a short period of time [14]. In addition, alkaline water is generated in the cathode chamber in the same volume as strongly acidic electrolyzed water in the anode chamber. Thus, only half the volume of the sodium chloride solution (the stock solution) is obtained as a sterilizing solution. An aqueous solution (neutral electrolyzed water, or NEW) obtained by mixing the aforementioned acidic electrolyzed water in the anode chamber and alkaline water in the cathode chamber also has potent sterilizing action [15-17]. However, this is a mixture of 2 solutions, so it is unlikely to stabilize as the chemical reaction proceeds. SAEW was researched and developed by Japanese companies in the 1990s. In 1996, Morinaga Milk Industry Co. and Morinaga Engineering Co. applied for a patent on a method of production and production equipment, and the Japanese patent (JP 3798486) was registered in 2006. In contrast to AEW, SAEW has the same potent sterilizing action and is more stable [18]. Killing spores is extremely difficult because they are highly resistant to heat, so they often cause food poisoning. In the current study, SAEW with an available chlorine concentration of about 30 mg/L was able to kill Bacillus spores. If spores attached to food ingredients can readily be eliminated by SAEW beforehand, then this should reduce food poisoning. Measures are needed to deal with airborne microorganisms in spaces occupied by people, such as food factories, waiting areas in hospitals, in airplanes, and greenhouses. In addition, reducing airborne viruses in pens and coops at hog and poultry farms is also a major need. Spatial sterilization is generally performed using ozone. However, ozone is highly toxic, and the allowable concentration in working environments is 0.05–0.1 ppm in most countries. Thus, sterilization with air containing ozone involves isolating humans and disinfected spaces and passing air through removal equipment after ozone sterilization, making the process expensive. An air purifier is a system that sucks in air, purifies it via filtration, disinfection, or some other method, and then released purified air. This all takes time. Thus, the strong sterilization performance without need for air purification afterwards is sufficient reason to explore the potential for use of SAEW in aerial disinfection. There are no systematic or standardized methods for assessing the microbiological effects of agents dispersed in air. One index can be found in the Methods for Assessing and Testing the Removal of Airborne Viruses by an Air Purifier devised by the Japan Electrical Manufacturers’ Association (2011). According to that document, an effective removal is when the amount of the logarithmic decrease is greater than or equal to 2.0. In the current experiments, that standard served as a reference while being mindful of that airborne microorganisms were being eradicated. A logarithmic decrease of 3.43 was noted in just 20 min. Even after subtracting the amount attenuated by sterile water, SAEW was sufficiently effective in killing airborne microorganisms. There are few studies on the disinfection mechanism of SAEW. Ding et al. [19] found that SAEW disrupted permeability of the cell membrane and the cytoplasmic ultrastructure in S. aureus cells. Kim at al. [20] studied cell morphological states and cell permeability through a transmission electron microscope and found that SAEW could penetrate bacterial cell walls and induce cell damage and disruption. Wigginton el al. [21] identified the virus inactivation mechanisms as free chlorine (FC), reporting that FC caused losses in both genome replication and protein-mediated functions. They suggested that FC altered the capsid structure which facilitates access to protein structures that are inside. SAEW has been sprayed at numerous sites such as hospitals, care facilities, kindergartens, and greenhouses in Japan over the past few years [8, 22], with no reports of health incidents due to the spraying. There are no statistically standardized methods of generally assessing the safety of spraying an antiseptic solution. COVID-19 is not yet under control, and SAEW is likely to be a way to help deal with that pandemic. Research on SAEW, including its safety, needs to be accelerated in the future.

5 Conclusions

Issues with the safety of sodium hypochlorite have been noted over the past few years. SAEW has gained attention as a replacement disinfectant, so the current experiment examined its sterilizing action. Results indicated that SAEW with an available chlorine concentration of about 30 mg/L has sufficient sterilizing action, even able to kill Bacillus spores within 15 minutes. E. coli, P aeruginosa, S. enterica, S. aureus, and S. epidermidis were eliminated within 15 sec of 30 mg/L of SAEW exposure. In addition, C. cladosporioides was removed within 60 sec of exposure to SAEW of 30 mg/L. Spatial spraying of SAEW with an available chlorine concentration of about 30 mg/L significantly disinfected a space the size of a small room in a short period of time. (XLSX) Click here for additional data file. 4 Feb 2021 PONE-D-20-33738 Spatial disinfection potential of slightly acidic electrolyzed water PLOS ONE Dear Dr. Naka, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. In addition to review comments, you failed to disclose any potential conflict of interest with the SAEW solution used your study. Please ensure to include the product number of the SAEW used, if it is commercially available, otherwise, provide details pertaining to SAEW formulation.  Funding details are also not disclosed, please add this information in the acknowledgment section. When reviewing the experimental design dealing with indoor spraying of SAEW, no information was provided as to why S. epiderrmidis was the only selected organism for this study. Why were other previously investigated species not tested in this assay, considering that outcomes may vary from the use of SAEW directly on pure culture or indirectly via indoor spraying? Finally, the antimicrobial potency of SAEW in your study was established based on CFU counts. Have you looked into other methods for validating cell death? Please submit your revised manuscript by Mar 13 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols We look forward to receiving your revised manuscript. Kind regards, Olivier Habimana Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. Thank you for stating the following in the Competing Interests section: "The authors have declared that no competing interests exist" We note that one or more of the authors are employed by a commercial company: Organo Food Tech Corporation. (1) Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form. Please also include the following statement within your amended Funding Statement. “The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.” If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement. (2) Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc. Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and  there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared. Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf. Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: I Don't Know ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors submitted a document about the use of slightly acidic electrolyzed water on spatial disinfection. It is a very relevant document however, there are some points that need to be clarified. L42. Authors stablished that sodium hypochlorite is highly safe however in some European countries, its use is banned. It will need to be modify. L74. The manuscript stablished: “Spatial disinfection with a conventional agent involves spraying in an unoccupied space or using protective equipment. Spatial disinfection can be performed with a low concentration of SAEW” At the end of the paragraph, authors cited this document https://doi.org/10.1637/11107-042115-Reg.1where it is stablished that Newcastle virus is affected by the use of higher concentration of SAEW (100 ppm). Authors need to clarify its statement. L80. It is a little confuse because authors wrote about the impact of multidrug-resistant microorganisms and the necessity for big area disinfection like food factories, hospitals, care facilities, kindergartens, and animal pens and coops. So, it is implying that the study will focus about airborne pathogens. But, at L94, most of the pathogens are not airborne. I believe authors needs to justify it statement why they are using bacteria like Salmonella enterica, Staphylococcus aureus and/or E. coli. L172. It is confused when in text authors use CFU/mL, then on L174 log10 CFU/mL. Please, use only one type of units. I recommend using log10 CFU/mL. L276. There is no reference on the use of EW on those facilities. Authors worked with S. epidermis, which causes biofilms. Results are interesting however, I suggest performing an in vitro study with this bacteria and to sample walls of the chamber where indoor study was performed. This will provide extra information about the survival/escaped bacteria after EW air treatment. Because SAEW is not a neutral water, its pH could affect/damage different surfaces. It could be interesting to perform a corrosion test. ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. Submitted filename: PlosOne_FRD_Jan21.docx Click here for additional data file. 25 Mar 2021 We would like to thank the editor and the reviewers for their time to read our manuscript PONE-D-20-33738 “Spatial disinfection potential of slightly acidic electrolyzed water” and giving us valuable comments and suggestions to improve its quality. We have revised the manuscript accordingly. Our responses to the editor and reviewers’ comments are as follows. ----------------- <1.1> In addition to review comments, you failed to disclose any potential conflict of interest with the SAEW solution used your study. Please ensure to include the product number of the SAEW used, if it is commercially available, otherwise, provide details pertaining to SAEW formulation. Funding details are also not disclosed, please add this information in the acknowledgment section. <1.1 Response> We would like to thank the editor for the valuable comments and suggestions. We conducted this research with the annual budget of the University of Tokyo. However, this budget was to conduct several research projects, not specifically to work on SAEW research. Following the editor's advice (by email), we left the Acknowledgements section unchanged: Lines 309-310 “The authors would also like to thank the anonymous reviewer for their valuable comments.” We discussed experimental design and results (conceptualization and validation) with Organo Food Tech Corporation. They also provided the SAEW and the clean chamber for the spatial disinfection test (resources). Regarding SAEW, we added the following information: Lines 128-129 “Slightly acidic electrolyzed water (HOCL0.36 t, HOCL Inc.) was specifically prepared by Organo Food Tech, Saitama, Japan for the purpose of these experiments.” ----------------- <1.2> When reviewing the experimental design dealing with indoor spraying of SAEW, no information was provided as to why S. epidermidis was the only selected organism for this study. Why were other previously investigated species not tested in this assay, considering that outcomes may vary from the use of SAEW directly on pure culture or indirectly via indoor spraying? <1.2 Response> We conducted spatial disinfection experiments only with S. epidermidis because it is generally regarded as a safe microorganism that is present in human skin and usually does not cause pyogenic infections unless there are compromised patients. One of the objectives of this research is to report on the efficacy of SAEW when used as spray (mist). Considering that we do not have a proper infrastructure to spray pathogenic and infectious microorganisms, we selected S. epidermidis for spatial disinfection experiments. We added the following sentence: Lines 122-125 S. epidermidis was the only microorganism selected for spatial disinfection experiments because it is a common bacterium present in the human skin and, thus, does not usually cause infections in non-compromised patients and does not require high level of biosafety laboratories.” To show the effectiveness of SAEW on other pathogenic bacteria, we conducted experiments on pure culture. ----------------- <1.3> Finally, the antimicrobial potency of SAEW in your study was established based on CFU counts. Have you looked into other methods for validating cell death? <1.3 Response> No, we have not investigated other methods for validating cell death. We used CFU count method because we found that this is one of the most common methods used by research teams that worked on research related to bacterium removal efficacy. ----------------- <2.1> The authors submitted a document about the use of slightly acidic electrolyzed water on spatial disinfection. It is a very relevant document however, there are some points that need to be clarified. L42. Authors stablished that sodium hypochlorite is highly safe however in some European countries, its use is banned. It will need to be modify. <2.1 Response> The authors would like to thank the reviewer for the feedback and suggestions to improve our manuscript. The reviewer is right, even though the use of sodium hypochlorite is still allowed in some countries such as Japan and Korea, its use is banned in many countries. So, we modified the sentence as follows: Lines 42-44 Sodium hypochlorite solutions are inexpensive and relatively effective, so they have been used around the world for over 100 years.” ----------------- <2.2> L74. The manuscript stablished: “Spatial disinfection with a conventional agent involves spraying in an unoccupied space or using protective equipment. Spatial disinfection can be performed with a low concentration of SAEW” At the end of the paragraph, authors cited this document https://doi.org/10.1637/11107-042115-Reg.1where it is stablished that Newcastle virus is affected by the use of higher concentration of SAEW (100 ppm). Authors need to clarify its statement. <2.2 Response> The reviewer is right, Newcastle virus was affected by 50 and 100 mg/L of free chlorine concentration. SAEW disinfection effectiveness depends on the type and concentration of the microorganisms. It also depends on the SAEW’s free chlorine concentration and the sprayed volume and duration. Unfortunately, there are very few experiments on spatial disinfection effectivity of SAEW. We added references of research works that were conducted with 30 mg/L and 80 mg/L of free chlorine concentration. Please refer to the following paragraph: Lines 77-82 “Spatial disinfection can be performed spraying SAEW with free chlorine concentrations of 100 mg/L or lower and without concern for residual chlorine. There are numerous studies on the sterilizing action of electrolyzed water, but there are very few studies on the use of SAEW for indoor disinfection [4-6].” ----------------- <2.3> L80. It is a little confuse because authors wrote about the impact of multidrug-resistant microorganisms and the necessity for big area disinfection like food factories, hospitals, care facilities, kindergartens, and animal pens and coops. So, it is implying that the study will focus about airborne pathogens. But, at L94, most of the pathogens are not airborne. I believe authors needs to justify it statement why they are using bacteria like Salmonella enterica, Staphylococcus aureus and/or E. coli. <2.3 Response> The reviewer is correct, not all species tested in this research are airborne bacteria. One of the objectives of this research is to evaluate the efficacy of SAEW against bacteria when applied as spray (mist). Unfortunately, our laboratory does not have a proper infrastructure to spray pathogenic and infectious bacteria. So, we conducted spray experiments only with S. epidermidis which is generally regarded as a safe microorganism unless there are compromised patients. To evaluate the effectiveness of SAEW against pathogenic bacteria and bacterial spores, we applied SAEW directly to pure culture (we can handle them in our biological safety cabinet). We added the following paragraph: Lines 77-82 “Its efficacy as disinfectant was measured in this research by directly applying SAEW on different types of bacteria and bacterial spores. Spatial disinfection can be performed spraying SAEW with free chlorine concentrations of 100 mg/L or lower and without concern for residual chlorine. There are numerous studies on the sterilizing action of electrolyzed water, but there are very few studies on the use of SAEW for indoor disinfection [4-6].” ----------------- <2.4> L172. It is confused when in text authors use CFU/mL, then on L174 log10 CFU/mL. Please, use only one type of units. I recommend using log10 CFU/mL. <2.4 Response> The reviewer is right. We corrected the mistake as follows: Lines 176-177 “Treatment of B. cereus (spores), a gram-positive bacillus that causes food to spoil, resulted in 1/10 of the original log10 CFU/mL after 60 sec.” ----------------- <2.5> L276. There is no reference on the use of EW on those facilities. <2.5 Response> Following the reviewer’s suggestion, we added the references accordingly. Lines 288-290 SAEW has been sprayed at numerous sites such as hospitals, care facilities, kindergartens, and greenhouses in Japan over the past few years [8, 22], with no reports of health incidents due to the spraying.” ----------------- <2.6> Authors worked with S. epidermidis, which causes biofilms. Results are interesting however, I suggest performing an in vitro study with this bacteria and to sample walls of the chamber where indoor study was performed. This will provide extra information about the survival/escaped bacteria after EW air treatment. Because SAEW is not a neutral water, its pH could affect/damage different surfaces. It could be interesting to perform a corrosion test. <2.6 Response> We performed two type of experiments: - In vitro experiments with pathogenic and infectious bacteria and bacterial spores. - Spray experiment with S. epidermidis, regarded as a safe microorganism (it is present in the human skin) and usually does not cause pyogenic infections unless there are compromised patients. The reviewer is correct, some bacteria may adhere to the walls. However, considering that SAEW’s free chlorine concentration is 41 ppm (this means that 99.59% is water), we believe that SAEW spray is not suitable for surface disinfection. For surface disinfection, it is more effective if we apply SAEW directly and in great amount. In this experiment we focused on bacteria that were suspended in the chamber and tested both SAEW and water, the latter as control. Hypochlorous acid (HOCl), which is the active molecule in SAEW, easily reacts with organic matter. Thus, if applied as spray (considering that HOCl concentration in SAEW is low), it will probably react with some dust on the surface and not with the bacteria. Regarding experiments with slightly acidic water, it could be interesting, but we believe that pH 6 may not have great impact on bacteria tested in this research. These bacteria usually show protection mechanisms against acid stress and overcome the challenge posed by different acidic environments. ----------------- <3.1> L101 – 102 …. on nutrient agar (Eiken Chemical Co.) and B. subtilis was cultured on soybean-casein digest agar (Eiken Chemical… L111. … was cultured on potato dextrose agar…. L118 ….. cultured in a heart infusion broth… L133soybean-casein digest medium L152 – 153 ….ultrasonic humidifier.. Please add the code number of all used media and machine/equipment not only the brand or which company they are form. <3.1 Response> The reviewer is correct. We followed the reviewer suggestion and added the necessary information. Lines 101-102 B. cereus was cultured on nutrient agar PT2810 (Eiken Chemical Co.) and B. subtilis was cultured on soybean-casein digest agar PT8010 (Eiken Chemical Co.)” Lines 108-109 E. coli, P. aeruginosa, S. enterica, and S. aureus were each cultured on nutrient agar PT 1010 (Eiken Chemical Co.) at 35℃±1℃ for 18–24 h.” Lines 111-113 C. cladosporioides was cultured on potato dextrose agar PT 2610 (Eiken Chemical Co.) at 25℃±1℃ for 7–10 days.” Lines 118-120 “The test bacterium was cultured in a brain heart infusion broth PT3025 (Eiken Chemical Co.) at 35℃±1℃ for 18–24 h.” Lines 136-145 “This test solution was stored at 20℃±1℃. After 15 s, 1 min, and 15 min, it was immediately diluted 10-fold with soybean-casein digest medium with polysorbate 80 & lecithin SCDLP “DAIGO” (Nihon Pharmaceutical Co.). Microorganisms in the test solution were counted using a medium for cultivation and isolation. The medium for cultivation and isolation was soybean-casein digest agar with polysorbate 80 & lecithin SCDLP “DAIGO” (Nihon Pharmaceutical Co.) for B. cereus, B. subtilis, E. coli, P. aeruginosa, S. enterica, and S. aureus. Each bacterium was then cultured at 35℃±1℃ for 2 days using the pour plate method. The medium for cultivation and isolation was glucose peptone agar with lecithin & polysorbate 80 GPLP AGAR “DAIGO” (Nihon Pharmaceutical Co.) for C. cladosporioides.” Lines 155-158 “Three mL of this mixture (2 mL of the bacterial solution + 1 mL of PBS) was sprayed at a rate of 1 mL/min for 3 min from the spray nozzle of an ultrasonic humidifier AHD-012 (Shizuku Plus+, Apix International, Osaka, Japan) in a large clean chamber.” ----------------- <3.2> L 126 – 128. SAEW used in the experiment involving pure cultures had an available chlorine concentration of 30 mg/kg and a pH of 5.9. SAEW used in the spatial disinfection experiment had an available chlorine concentration of 41 mg/kg and a pH of 6.0. Why the available chlorine concentration used for pure culture and in spatial disinfection experiment were different? <3.2 Response> We conducted spatial disinfection experiments as soon as we received the SAEW from Organo Food Tech Corporation. At that time, the concentration of free chlorine was 41 mg/L. Some weeks later, we conducted experiments on pure culture. At that time, the concentration was 30 mg/L (free chlorine concentration decreased with time, but it was still effective). We measured free chlorine concentration just before experiments. ----------------- <3.3> 2.3. Effects of SAEW on pure cultures. How many replication samples you’ve done for each microorganism? <3.3 Response> We performed experiments in triplicate. We added this information in the manuscript. Please refer to Line 148. Line 148 “All experiments were performed in triplicate.” ----------------- <3.4> 2.4. Effects of indoor spraying of SAEW. How many replications process (not sampling time) you’ve done in this study? <3.4 Response> We performed indoor spraying experiments three times. We added this information in the manuscript. Please refer to Line 163. Line 163 “This experiment was repeated three times.” ----------------- <3.5> Statistical analysis. Please provide information about the statistical tool that been used. <3.5 Response> The obtained results were statistically assessed using Tukey’s honestly significant difference (HSD) test. Please refer to Lines 167-169. Lines 167-169 “The obtained results were statistically assessed using Tukey’s honestly significant difference (HSD) test, with P < 0.05 considered to be statistically significant.” ----------------- <3.6> Discussion. The discussions are not deep enough. I can’t see the discussion of the mechanism on how the SAEW can inhibit or reduce the microbial growth in the studies. <3.6 Response> The reviewer is right. We added the following paragraph regarding SAEW’s bacteria inhibition mechanism. Lines 278-286 “There are few studies on the disinfection mechanism of SAEW. Ding et al. [19] found that SAEW disrupted permeability of the cell membrane and the cytoplasmic ultrastructure in S. aureus cells. Kim at al. [20] studied cell morphological states and cell permeability through a transmission electron microscope and found that SAEW could penetrate bacterial cell walls and induce cell damage and disruption. Wigginton el al. [21] identified the virus inactivation mechanisms as free chlorine (FC), reporting that FC caused losses in both genome replication and protein-mediated functions. They suggested that FC altered the capsid structure which facilitates access to protein structures that are inside.” ----------------- <3.7> General comments - The manuscript is well written. However, some details are missing. - It is crucial to give the detail of all medias and used equipment/tools/machines being used. This information is needed to verify your methods and enable the reader mimicking your study. - The discussions are not deep enough. I can’t see the discussion of the mechanism on how the SAEW can inhibit or reduce the microbial growth in the studies. <3.7 Response> We would like to thank the reviewer for the feedback. We revised the manuscript according to the reviewer’s comments and suggestions. ----------------- Submitted filename: Response to Reviewers.docx Click here for additional data file. 20 Apr 2021 PONE-D-20-33738R1 Spatial disinfection potential of slightly acidic electrolyzed water PLOS ONE Dear Dr. Naka, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Jun 04 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Olivier Habimana Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: I previously suggested to authors to perform an in vitro study with S. epidermidis, authors answer me back the following statement: we believe that pH 6 may not have great impact on bacteria tested in this research. These bacteria usually show protection mechanisms against acid stress and overcome the challenge posed by different acidic environments. It is not clear why authors make that statement if results show that spatial disinfection worked properly. I suggest including an in vitro study with S. epidermidis. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: Yes: Jose Alberto Cano-Buendia [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 3 Jun 2021 <1.1> I previously suggested to authors to perform an in vitro study with S. epidermidis, authors answer me back the following statement: we believe that pH 6 may not have great impact on bacteria tested in this research. These bacteria usually show protection mechanisms against acid stress and overcome the challenge posed by different acidic environments. It is not clear why authors make that statement if results show that spatial disinfection worked properly. I suggest including an in vitro study with S. epidermidis. We would like thank the reviewer for the valuable comment and suggestion. As suggested by the reviewer, we performed in vitro experiments with S. epidermidis and added the results in the manuscript. Please refer to Lines 94-100, 113-116, 144-146, 187-189, 193-196 and 309-310 and Figure 1. Lines 94-100 An in vitro experiment was performed with Bacillus cereus NBRC 13494, Bacillus subtilis NBRC 3134, Pseudomonas aeruginosa NBRC 13275, Salmonella enterica subsp. enterica NBRC 3313, Staphylococcus aureus subsp. aureus NBRC 12732, Cladosporium cladosporioides NBRC 6348, and Staphylococcus epidermidis NBRC 12993 from the NITE Biological Resource Center (NBRC, Japan) and Escherichia coli ATCC 43895 (serotype O157:H7, a verotoxin I and II-producing strain) from the American Type Culture Collection (ATCC, USA). Lines 113-116 S. epidermidis was cultured in a brain heart infusion broth PT3025 (Eiken Chemical Co.) at 35℃±1℃ for 18–24 h. The bacterial count was adjusted to 107-108 CFU/mL with a sterile phosphate buffer (phosphate-buffered saline, or PBS) to yield the test bacterial solution. Lines 144-146 The medium for cultivation and isolation was soybean-casein digest agar with polysorbate 80 & lecithin SCDLP “DAIGO” (Nihon Pharmaceutical Co.) for B. cereus, B. subtilis, E. coli, P. aeruginosa, S. enterica, S. aureus, and S. epidermidis Lines 187-189 Treatment of S. aureus and S. epidermidis, gram-positive facultative anaerobic bacilli, with electrolyzed water resulted in logarithmic (log10 CFU/mL) decrease of 5.2 or greater and 5.4 or greater, respectively within 15 sec. Lines 193-196 Fig 1. Effects of SAEW on pure cultures (a) Bacillus cereus, (b) Bacillus subtilis, (c) Escherichia coli (O157:H7), (d) Pseudomonas aeruginosa, (e) Salmonella enterica subsp. enterica, (f) Staphylococcus aureus subsp. aureus, (g) Cladosporium cladosporioides, and (h) Staphylococcus epidermidis. Line 307-310 Results indicated that SAEW with an available chlorine concentration of about 30 mg/L has sufficient sterilizing action, even able to kill Bacillus spores within 15 minutes. E. coli, P aeruginosa, S. enterica, S. aureus, and S. epidermidis were eliminated within 15 sec of 30 mg/L of SAEW exposure. As for the statement regarding pH, the reviewer is correct, this does not answer the reviewer’s question. We wanted to mention that the disinfectant capacity of SAEW is attributed to the presence of HOCl. Submitted filename: Response to Reviewers June 3.docx Click here for additional data file. 9 Jun 2021 Spatial disinfection potential of slightly acidic electrolyzed water PONE-D-20-33738R2 Dear Dr. Naka, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Olivier Habimana Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: 24 Jun 2021 PONE-D-20-33738R2 Spatial disinfection potential of slightly acidic electrolyzed water Dear Dr. Naka: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Olivier Habimana Academic Editor PLOS ONE
  13 in total

1.  Virus inactivation mechanisms: impact of disinfectants on virus function and structural integrity.

Authors:  Krista Rule Wigginton; Brian M Pecson; Thérese Sigstam; Franziska Bosshard; Tamar Kohn
Journal:  Environ Sci Technol       Date:  2012-10-26       Impact factor: 9.028

2.  Roles of oxidation-reduction potential in electrolyzed oxidizing and chemically modified water for the inactivation of food-related pathogens.

Authors:  C Kim; Y C Hung; R E Brackett
Journal:  J Food Prot       Date:  2000-01       Impact factor: 2.077

Review 3.  Impact of climate change on human infectious diseases: Empirical evidence and human adaptation.

Authors:  Xiaoxu Wu; Yongmei Lu; Sen Zhou; Lifan Chen; Bing Xu
Journal:  Environ Int       Date:  2015-10-18       Impact factor: 9.621

4.  Enhancing the bactericidal effect of electrolyzed water on Listeria monocytogenes biofilms formed on stainless steel.

Authors:  Beatrice Ayebah; Yen-Con Hung; Joseph F Frank
Journal:  J Food Prot       Date:  2005-07       Impact factor: 2.077

5.  Aerosol Disinfection Capacity of Slightly Acidic Hypochlorous Acid Water Towards Newcastle Disease Virus in the Air: An In Vivo Experiment.

Authors:  Hakimullah Hakim; Chanathip Thammakarn; Atsushi Suguro; Yuki Ishida; Katsuhiro Nakajima; Minori Kitazawa; Kazuaki Takehara
Journal:  Avian Dis       Date:  2015-12       Impact factor: 1.577

6.  Efficacy of electrolyzed oxidizing (EO) and chemically modified water on different types of foodborne pathogens.

Authors:  C Kim; Y C Hung; R E Brackett
Journal:  Int J Food Microbiol       Date:  2000-11-01       Impact factor: 5.277

7.  Efficacy of neutral electrolyzed water (NEW) for reducing microbial contamination on minimally-processed vegetables.

Authors:  Maribel Abadias; Josep Usall; Márcia Oliveira; Isabel Alegre; Inmaculada Viñas
Journal:  Int J Food Microbiol       Date:  2008-01-30       Impact factor: 5.277

8.  Inactivation of Escherichia coli O157:H7, Salmonella enteritidis and Listeria monocytogenes on the surface of tomatoes by neutral electrolyzed water.

Authors:  M A Deza; M Araujo; M J Garrido
Journal:  Lett Appl Microbiol       Date:  2003       Impact factor: 2.858

9.  Effectiveness of electrolyzed acidic water in killing Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes on the surfaces of tomatoes.

Authors:  M L Bari; Y Sabina; S Isobe; T Uemura; K Isshiki
Journal:  J Food Prot       Date:  2003-04       Impact factor: 2.077

10.  Carcinogenicity of chloroform.

Authors:  M D Reuber
Journal:  Environ Health Perspect       Date:  1979-08       Impact factor: 9.031

View more
  1 in total

1.  Rapid in vitro virucidal activity of slightly acidic hypochlorous acid water toward aerosolized coronavirus in simulated human-dispersed droplets.

Authors:  Yu Miyaoka; Makiko Yamaguchi; Chisaki Kadota; Md Amirul Hasan; Md Humayun Kabir; Dany Shoham; Harumi Murakami; Kazuaki Takehara
Journal:  Virus Res       Date:  2022-01-29       Impact factor: 3.303

  1 in total