Literature DB >> 34209425

Selective Membrane Sensor for Aluminum Determination in Food Products, Real Samples and Standard Alloys.

Sabry Khalil1, Ashraf Y Elnaggar1.   

Abstract

The study involves the fabrication of an aluminum liquid membrane sensor based on the association of aluminum ions with the cited reagent 2,9-dimethyl-4,11-diphenyl -1,5,8,12-tetraaza cyclote tradeca-1,4,8,11-tetraene [DDTCT]. The characteristics slope (58 mV), rapid and linear response for aluminum ion was displayed by the proposed sensor within the concentration range 2.5 × 10-7-1.5 × 10-1 M, the detection limit (1.6 × 10-7) M, the selectivity behavior toward some metal cations, the response time 10 s), lifetime (150 days), the effect of pH on the suggested electrode potential and the requisite analytical validations were examined. The suitable pH range was (5.0-8.0 ), in this range the proposed electrode response is independent of pH. The suggested electrode was applied to detect the aluminum ions concentration in food products, real samples and standard alloys. The resulting data by the suggested electrode were statistically analyzed, and compared with the previously reported aluminum ion-selective electrodes in the literature.

Entities:  

Keywords:  alloys analysis; aluminum estimation; food; ion-associate tetraaza tetraene complexes; membrane sensor; real samples

Year:  2021        PMID: 34209425     DOI: 10.3390/membranes11070504

Source DB:  PubMed          Journal:  Membranes (Basel)        ISSN: 2077-0375


  25 in total

1.  Neuromelanin-containing neurons of the substantia nigra accumulate iron and aluminum in Parkinson's disease: a LAMMA study.

Authors:  P F Good; C W Olanow; D P Perl
Journal:  Brain Res       Date:  1992-10-16       Impact factor: 3.252

2.  Bifunctional bimetallic heterojunction material based on Al2O3/ZnO micro flowers for electrochemical sensing and catalysis.

Authors:  Vengudusamy Renganathan; Ramachandran Balaji; Shen-Ming Chen; Sakthivel Kogularasu; Muthumariappan Akilarasan
Journal:  Ecotoxicol Environ Saf       Date:  2019-03-30       Impact factor: 6.291

3.  Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry.

Authors:  Mei Sun; Qianghua Wu
Journal:  J Hazard Mater       Date:  2009-11-27       Impact factor: 10.588

4.  Determination of aluminium using different techniques based on the Al(III)-morin complex.

Authors:  Olga Domínguez-Renedo; A Marta Navarro-Cuñado; Eduardo Ventas-Romay; M Asunción Alonso-Lomillo
Journal:  Talanta       Date:  2018-12-15       Impact factor: 6.057

5.  Aluminum determination in biological fluids and dialysis concentrates via chelation with 8-hydroxyquinoline and solvent extraction/fluorimetry.

Authors:  M Buratti; C Valla; O Pellegrino; F M Rubino; A Colombi
Journal:  Anal Biochem       Date:  2006-04-18       Impact factor: 3.365

6.  Fluorimetric determination of magnesium and aluminum via complexation with oxine in high-performance liquid chromatography.

Authors:  T Takeuchi; S Inoue; M Yamamoto; M Tsuji; T Miwa
Journal:  J Chromatogr A       Date:  2001-03-02       Impact factor: 4.759

7.  Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrix.

Authors:  Vinod K Gupta; Ajay K Jain; Gaurav Maheshwari
Journal:  Talanta       Date:  2007-02-09       Impact factor: 6.057

8.  Spectrophotometric determination of aluminium and indium with 2,2',3,4-tetrahydroxy-3',5'-disulphoazobenzene.

Authors:  A A Huseyinli; R Alieva; S Haciyeva; T Güray
Journal:  J Hazard Mater       Date:  2008-07-23       Impact factor: 10.588

9.  Speciation of aluminum in soil extracts using cation and anion exchangers followed by a flow-injection system with fluorescence detection using lumogallion.

Authors:  Etsu Yamada; Takayuki Hiwada; Takashi Inaba; Motoaki Tokukura; Yasuro Fuse
Journal:  Anal Sci       Date:  2002-07       Impact factor: 2.081

10.  Aluminium determination in environmental samples by graphite furnace atomic absorption spectrometry after solid phase extraction on Amberlite XAD-1180/pyrocatechol violet chelating resin.

Authors:  Ibrahim Narin; Mustafa Tuzen; Mustafa Soylak
Journal:  Talanta       Date:  2004-05-28       Impact factor: 6.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.