| Literature DB >> 34195636 |
Benjamin Sherman1,2, Kevin Kwan1, John Schlechter1,2.
Abstract
PURPOSE: To evaluate the predictive value of magnetic resonance imaging in determining hamstring autograft size preoperatively for pediatric anterior cruciate ligament reconstruction.Entities:
Year: 2021 PMID: 34195636 PMCID: PMC8220624 DOI: 10.1016/j.asmr.2021.01.009
Source DB: PubMed Journal: Arthrosc Sports Med Rehabil ISSN: 2666-061X
Fig 1Magnetic resonance imaging of a right knee cross section showing the measurement technique for determining the cross-sectional area (A) of the semitendinosus and gracilis tendons using the field-of-interest tool.
Fig 2Magnetic resonance imaging of a right knee cross section showing the measurement technique for determining the anteroposterior and mediolateral diameters of the semitendinosus and gracilis tendons.
Demographic Data Comparing Patients by Graft Size (<8 mm or ≥8 mm)
| Mean | 95% CI | ||||||
|---|---|---|---|---|---|---|---|
| Lower | Upper | ||||||
| Graft Size < 8 mm | Graft Size ≥ 8 mm | Graft Size < 8 mm | Graft Size ≥ 8 mm | Graft Size < 8 mm | Graft Size ≥ 8 mm | ||
| Height, cm | 162.28 | 169.02 | 159.66 | 166.56 | 164.90 | 171.47 | <.001 |
| Weight, kg | 67.35 | 76.88 | 62.27 | 71.16 | 72.43 | 82.6 | .014 |
| BMI | 25.38 | 26.57 | 23.77 | 25.12 | 26.99 | 28.02 | .274 |
| Age, yr | 15.89 | 15.97 | 15.39 | 15.57 | 16.38 | 16.37 | .793 |
BMI, body mass index; CI, confidence interval.
MRI Measurements Comparing Patients by Graft Size (<8 mm or ≥8 mm)
| Mean | 95% CI | ||||||
|---|---|---|---|---|---|---|---|
| Lower | Upper | ||||||
| Graft Size < 8 mm | Graft Size ≥ 8 mm | Graft Size < 8 mm | Graft Size ≥ 8 mm | Graft Size < 8 mm | Graft Size ≥ 8 mm | ||
| ST | |||||||
| XSA, mm2 | 15.83 | 19.15 | 14.86 | 18.14 | 16.81 | 20.16 | <.001 |
| AP diameter, mm | 4.82 | 5.17 | 4.66 | 4.97 | 4.99 | 5.37 | .009 |
| ML diameter, mm | 4.02 | 4.49 | 3.84 | 4.33 | 4.21 | 4.65 | <.001 |
| GT | |||||||
| XSA, mm2 | 9.84 | 11.33 | 9.22 | 10.68 | 10.46 | 11.98 | .001 |
| AP diameter, mm | 4.22 | 4.58 | 4.09 | 4.36 | 4.36 | 4.8 | .01 |
| ML diameter, mm | 2.87 | 3.1 | 2.75 | 2.97 | 2.99 | 3.22 | .013 |
| ST and GT | |||||||
| XSA, mm2 | 25.67 | 30.48 | 24.32 | 29.03 | 27.02 | 31.93 | <.001 |
| Diameter, mm | 15.94 | 17.33 | 15.55 | 16.9 | 16.33 | 17.77 | <.001 |
AP, anteroposterior; CI, confidence interval; G, gracilis tendon; ML, mediolateral; MRI, magnetic resonance imaging; ST, semitendinosus tendon; XSA, cross-sectional area.
Fig 3Receiver operator characteristic (ROC) curve of the predictive model for determining a hamstring autograft size of 8 mm or greater using the sum of the cross-sectional areas of the semitendinosus and gracilis tendons greater than 31.2 mm2.