| Literature DB >> 30937321 |
Nicolas Vardiabasis1, Brian Mosier2, Jason Walters3, Aaron Burgess2, Greg Altman2, Sam Akhavan2.
Abstract
BACKGROUND: Anterior cruciate ligament (ACL) reconstruction with a quadruple hamstring (QH) autograft is a widely utilized procedure with good outcomes. A graft diameter less than 8 mm, however, has been associated with higher revision rates. Accurately determining the diameter of the hamstring tendon preoperatively can help surgeons plan accordingly. PURPOSE/HYPOTHESIS: The purpose of our study was to determine whether QH graft size can be reliably predicted from preoperative magnetic resonance imaging (MRI) measurements. We hypothesized that we can achieve a high predicted QH graft size correlation with regard to preoperative and intraoperative measurements. STUDYEntities:
Keywords: anterior cruciate ligament; autograft; hamstring; magnetic resonance imaging
Year: 2019 PMID: 30937321 PMCID: PMC6435877 DOI: 10.1177/2325967119834504
Source DB: PubMed Journal: Orthop J Sports Med ISSN: 2325-9671
Figure 1.T2-weighted (A) coronal and (B) axial magnetic resonance imaging of a knee. The diameters of the gracilis tendon (GT) and semitendinosus tendon (ST) were measured at 3 cm from the joint line.
Correlation of ST and GT Diameters on MRI at 1-cm Increments to Intraoperatively Measured ST and GT Diameters
| Distance |
|
|
|---|---|---|
| 1 cm | 0.352 | .024 |
| 2 cm | 0.438 | .004 |
| 3 cm | 0.554 | .0001 |
| 4 cm | 0.513 | .001 |
| 5 cm | 0.275 | .082 |
GT, gracilis tendon; MRI, magnetic resonance imaging; ST, semitendinosus tendon.
Graft Diameter Combinations
| GT Diameter | ST Diameter | |||||||
|---|---|---|---|---|---|---|---|---|
| 3.5 mm | 4.0 mm | 4.5 mm | 5.0 mm | 5.5 mm | 6.0 mm | 6.5 mm | 7.5 mm | |
| 2.5 mm | 5.25 (2) | 6.25 (2) | 6.25 (2) | 7.33 (3) | 8.00 (1) | — | — | — |
| 3.0 mm | 5.75 (2) | 6.25 (2) | 7.50 (18) | 7.82 (11) | 8.20 (3) | 9.50 (2) | 10.00 (1) | 10.50 (1) |
| 3.5 mm | 6.13 (8) | 6.94 (8) | 7.87 (215) | 8.09 (116) | 8.52 (26) | 9.69 (24) | 10.15 (12) | 10.61 (12) |
| 4.0 mm | 6.75 (4) | 7.38 (4) | 8.03 (116) | 8.24 (62) | 8.59 (16) | 9.85 (14) | 10.07 (7) | 10.71 (7) |
| 4.5 mm | 7.25 (4) | 7.75 (4) | 8.49 (100) | 8.75 (54) | 9.28 (14) | 10.33 (12) | 10.67 (6) | 11.00 (6) |
| 5.0 mm | — | — | 7.88 (16) | 8.13 (8) | 8.50 (2) | 9.75 (2) | 10.00 (1) | 10.50 (1) |
| 6.5 mm | — | — | 11.06 (16) | 11.25 (8) | 11.50 (2) | 12.25 (2) | 12.50 (1) | 13.00 (1) |
Data are reported as diameter of graft in millimeters (No. of graft combinations). Dashes indicate that there were no graft combinations of that particular diameter. GT, gracilis tendon; ST, semitendinosus tendon.
Quadruple Hamstring Graft Predictive Table
| GT Diameter | ST Diameter | ||||
|---|---|---|---|---|---|
| 3.5 mm | 4.0 mm | 4.5 mm | 5.0 mm | 5.5 mm | |
| 2.5 mm | 5.5 | 6.5 | 6.5 | 7.5 | 8.0 |
| 3.0 mm | 6.0 | 6.5 | 7.5 | 8.0 | 8.5 |
| 3.5 mm | 6.5 | 7.0 | 8.0 | 8.5 | 9.0 |
| 4.0 mm | 7.0 | 7.5 | 8.5 | 8.5 | 9.0 |
| 4.5 mm | 7.5 | 8.0 | 8.5 | 9.0 | 9.5 |
Data are reported as diameter of graft in millimeters. Diameters rounded up to the nearest 0.5 mm correspond with standard graft sizing blocks. GT, gracilis tendon; ST, semitendinosus tendon.
Combined Accuracy of Preoperative MRI Measurements and Quadruple Hamstring Graft Predictive Table
| ≤0.5-cm Difference | ≤1.0-cm Difference |
|
| |
|---|---|---|---|---|
| GT | 45/60 (75) | 59/60 (98) | 0.6211 | <.00001 |
| ST | 45/60 (75) | 56/60 (93) | 0.7110 | <.00001 |
| Quadruple hamstring graft | 52/60 (87) | 60/60 (100) | 0.8107 | <.00001 |
Data are reported as n (%) unless otherwise specified. GT, gracilis tendon; MRI, magnetic resonance imaging; ST, semitendinosus tendon.
Previous Studies Using Preoperative MRI to Predict Intraoperative Hamstring Tendon Diameter
| Study | Population | Imaging Modality | Protocol Used | Correlation |
|---|---|---|---|---|
| Wernecke et al[ | N = 34 (9 F, 25 M) | 1.5-T MRI | CSA measured via ROI tool |
|
| Beyzadeoglu et al[ | N = 51 (7 F, 44 M) | 3.0-T MRI | CSA measured via ROI tool |
|
| Erquicia et al[ | N = 33 (8 F, 25 M) | 3.0-T MRI and US | MRI: CSA measured via ROI tool | MRI (4× magnification): |
| Grawe et al[ | N = 84 (42 F, 42 M) | 1.5-T or 3.0-T MRI | CSA measured via ROI tool |
|
| Leiter et al[ | N = 109 (44 F, 65 M) | 1.5-T MRI | CSA measured via ROI tool |
|
| Current study | N = 60 (26 F, 34 M) | 1.5-T MRI | Diameter of tendon at 3 cm from joint line |
|
CSA, cross-sectional area; F, female; M, male; MRI, magnetic resonance imaging; ROI, region of interest; US, ultrasound.