Literature DB >> 34189632

Balance Between Mechanical Stability and Mechano-Biology of Fracture Healing Under Volar Locking Plate.

Xuanchi Liu1, Saeed Miramini1, Minoo Patel2, JinJing Liao1, Darpan Shidid3, Lihai Zhang4.   

Abstract

The application of volar locking plate (VLP) is promising in the treatment of dorsally comminuted and displaced fracture. However, the optimal balance between the mechanical stability of VLP and the mechanobiology at the fracture site is still unclear. The purpose of this study is to develop numerical models in conjunction with experimental studies to identify the favourable mechanical microenvironment for indirect healing, by optimizing VLP configuration and post-operative loadings for different fracture geometries. The simulation results show that the mechanical behaviour of VLP is mainly governed by the axial compression. In addition, the model shows that, under relatively large gap size (i.e., 3-5 mm), the increase of FWL could enhance chondrocyte differentiation while a large BPD could compromise the mechanical stability of VLP. Importantly, bending moment produced by wrist flexion/extension and torsion moment produced from forearm rotation could potentially hinder endochondral ossification at early stage of healing. The developed model could potentially assist orthopaedic surgeons in surgical pre-planning and designing post-operation physical therapy for treatment of distal radius fractures.
© 2021. Biomedical Engineering Society.

Entities:  

Keywords:  Bone-to-plate distance; Distal radius fracture; Flexion working length; Fracture healing; Gap size; Volar locking plate

Mesh:

Year:  2021        PMID: 34189632     DOI: 10.1007/s10439-021-02815-x

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  35 in total

1.  Shear movement at the fracture site delays healing in a diaphyseal fracture model.

Authors:  Peter Augat; Johannes Burger; Sandra Schorlemmer; Thomas Henke; Manfred Peraus; Lutz Claes
Journal:  J Orthop Res       Date:  2003-11       Impact factor: 3.494

2.  Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses.

Authors:  Vaclav Baca; Zdenek Horak; Petr Mikulenka; Valer Dzupa
Journal:  Med Eng Phys       Date:  2008-02-20       Impact factor: 2.242

3.  Local tissue properties in bone healing: influence of size and stability of the osteotomy gap.

Authors:  P Augat; K Margevicius; J Simon; S Wolf; G Suger; L Claes
Journal:  J Orthop Res       Date:  1998-07       Impact factor: 3.494

4.  Age-Related Changes in the Mechanical Regulation of Bone Healing Are Explained by Altered Cellular Mechanoresponse.

Authors:  Edoardo Borgiani; Christine Figge; Bettina Kruck; Bettina M Willie; Georg N Duda; Sara Checa
Journal:  J Bone Miner Res       Date:  2019-07-29       Impact factor: 6.741

5.  Influence of size and stability of the osteotomy gap on the success of fracture healing.

Authors:  L Claes; P Augat; G Suger; H J Wilke
Journal:  J Orthop Res       Date:  1997-07       Impact factor: 3.494

Review 6.  Fracture healing under healthy and inflammatory conditions.

Authors:  Lutz Claes; Stefan Recknagel; Anita Ignatius
Journal:  Nat Rev Rheumatol       Date:  2012-01-31       Impact factor: 20.543

7.  Metaphyseal fracture healing follows similar biomechanical rules as diaphyseal healing.

Authors:  Lutz Claes; Martina Reusch; Melanie Göckelmann; Michael Ohnmacht; Tim Wehner; Michael Amling; Frank T Beil; Anita Ignatius
Journal:  J Orthop Res       Date:  2010-09-29       Impact factor: 3.494

8.  Induction of a neoarthrosis by precisely controlled motion in an experimental mid-femoral defect.

Authors:  Dennis M Cullinane; Amy Fredrick; Solomon R Eisenberg; Donna Pacicca; Michael V Elman; Cassandra Lee; Kristy Salisbury; Louis C Gerstenfeld; Thomas A Einhorn
Journal:  J Orthop Res       Date:  2002-05       Impact factor: 3.494

9.  Biomechanical considerations in the design of patient-specific fixation plates for the distal radius.

Authors:  G Caiti; J G G Dobbe; E Bervoets; M Beerens; S D Strackee; G J Strijkers; G J Streekstra
Journal:  Med Biol Eng Comput       Date:  2018-12-26       Impact factor: 2.602

10.  Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients.

Authors:  Antonio Abramo; Philippe Kopylov; Mats Geijer; Magnus Tägil
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.