Eyes-hands alignment during regional anesthesia procedures: The US support.

Alessandro Strumia1, Fabio Costa1, Giuseppe Pascarella1, Felice Eugenio Agrò1.   

Abstract

Entities:  

Year:  2021        PMID: 34188650      PMCID: PMC8191245          DOI: 10.4103/sja.sja_1096_20

Source DB:  PubMed          Journal:  Saudi J Anaesth


× No keyword cloud information.
To the Editor, There is great enthusiasm about new technologies applied to regional anesthesia[1] and their ability to solve well known technical issues, such as looking at the patients and at the ultrasound (US) images at the same time during US-guided procedures.[2] Not by chance, maintaining the eyes-hands alignment of the operator could facilitate the execution of peripheral blocks, especially in case of challenging position or difficult anatomy of the patient. In our experience, recently developed smartphone connectable wireless probes could be a great solution regarding this matter.[3] US wireless probe have been proven to be reliable in performing invasive anesthetic procedures and vascular cannulations,[4] combining optimal images resolution with the unique convenience of a portable probe, which can be used also in the emergency department and in the wards. Moreover, they are extremely cheaper if compared to traditional US machines, and the images and/or videos can be easily saved on the smartphone, and lately used for teaching purpose. In our institution, we routinely perform US-guided procedures using smartphone-connected wireless probes combined to a simple flexible neck mobile phone holder, which leaves the operator hands free: we called it the “US support”. This device permits to maintain the smartphone directly on the operator ideal eyes-hands line, as shown in Figure 1.
Figure 1

Pre-procedural ultrasound scan before IPACK (Infiltration Between Popliteal Artery and Capsule of Knee) block using a smartphone-connected wireless probe. The smartphone is held by a flexible neck mobile phone holder, permitting to maintain the eyes-hands alignment of the operator

Pre-procedural ultrasound scan before IPACK (Infiltration Between Popliteal Artery and Capsule of Knee) block using a smartphone-connected wireless probe. The smartphone is held by a flexible neck mobile phone holder, permitting to maintain the eyes-hands alignment of the operator These smartphone supports are very common, cheap and easy to use, and they can be adjusted according to the operator comfort. It is important to notice that smartphones are integrated part of everyone daily life and work practice, so their use is familiar to almost everyone. Moreover, in contrast to other solution proposed for this matter, such as head-mounted display, which would inevitably split the vision in two,[5] the US support allows the operator to maintain the binocular vison, which could give more confidence during the anesthetic procedure. New devices and technologies play a fundamental role in the evolution of regional anesthesia, inside and outside the operating room, such as in the emergency department. Adapting them to everyday practice will be a great challenge in the nearby future.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  5 in total

1.  Wireless Ultrasound Guidance for Femoral Venous Cannulation in Electrophysiology: Impact on Safety, Efficacy, and Procedural Delay.

Authors:  Daniel Rodríguez Muñoz; Eduardo Franco Díez; Javier Moreno; Giuseppe Lumia; Alejandra Carbonell San Román; Teresa Segura De La Cal; Roberto Matía Francés; Antonio Hernández Madrid; José Luis Zamorano Gómez
Journal:  Pacing Clin Electrophysiol       Date:  2015-06-23       Impact factor: 1.976

2.  U smart: ultrasound in your pocket.

Authors:  Alessandro Strumia; Fabio Costa; Giuseppe Pascarella; Romualdo Del Buono; Felice Eugenio Agrò
Journal:  J Clin Monit Comput       Date:  2020-03-30       Impact factor: 2.502

3.  Future in regional anesthesia: new techniques and technological advancements.

Authors:  Ece Yamak Altinpulluk; Alparslan Turan
Journal:  Minerva Anestesiol       Date:  2020-09-22       Impact factor: 3.051

4.  Letter to the editor: head-mounted display for regional anesthesia.

Authors:  Scott Hughey; Jacob Cole; Gregory Booth; Jason Longwell
Journal:  Reg Anesth Pain Med       Date:  2020-09-24       Impact factor: 6.288

5.  Simultaneous display of real-time ultrasound and surface landmark image.

Authors:  Ky Tan Huynh; Johnathan Chaika; Tae W Kim
Journal:  Reg Anesth Pain Med       Date:  2019-10-13       Impact factor: 6.288

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.