Literature DB >> 3415548

Configuration of corneal trephine opening using five different trephines in human donor eyes.

G van Rij1, G O Waring.   

Abstract

In this laboratory study, we used five different corneal trephines on 60 fresh human donor eyes with controlled intraocular pressure to study the variation in the size and shape of the trephine openings. With all trephines, the average diameter of the button was larger than the diameter of the trephine at the epithelial side (mean difference, 0.21 mm; range, 0.06 to 0.35 mm) and the endothelial side (mean difference, 0.42 mm; range, 0.13 to 0.79 mm), presumably because the corneal tissue protruded into the trephine during cutting. The trephines that produced the most uniform opening were a nondisposable suction trephine and a freestanding disposable blade, but they caused some undercutting.

Entities:  

Mesh:

Year:  1988        PMID: 3415548     DOI: 10.1001/archopht.1988.01060140388039

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  14 in total

1.  Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes.

Authors:  Milenko Stojkovic; Berthold Seitz; Michael Küchle; Achim Langenbucher; Arne Viestenz; Anja Viestenz; Carmen Hofmann-Rummelt; Gottfried O H Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

2.  Inadequacy of a polyester (Mersilene) suture for the reduction of astigmatism after penetrating keratoplasty.

Authors:  B A Bertram; C Drews; M Gemmill; J Guell; M Murad; G O Waring
Journal:  Trans Am Ophthalmol Soc       Date:  1990

3.  Configuration of recipient corneal cut after mechanical trephination in keratoconus.

Authors:  Sepehr Feizi; Maryam Najafi; Mohammad Ali Javadi; Amir A Azari
Journal:  Int Ophthalmol       Date:  2019-04-09       Impact factor: 2.031

Review 4.  [The penetrating keratoplasty. A 100-year success story].

Authors:  B Seitz; A Langenbucher; G O H Naumann
Journal:  Ophthalmologe       Date:  2005-12       Impact factor: 1.059

5.  Long-term refractive and visual outcome after penetrating keratoplasty only versus the triple procedure in Fuchs' dystrophy.

Authors:  Sujata Das; Achim Langenbucher; Christina Jacobi; Nhung X Nguyen; Friedrich E Kruse; Gottfried O H Naumann; Berthold Seitz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-01-14       Impact factor: 3.117

6.  The influence of the cutting procedure on the loss of corneal endothelial cells of the recipient eye in mechanically guided trephination.

Authors:  J Daniel; H J Huebscher
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-12       Impact factor: 3.117

7.  Excimer laser "corneal shaping": a new technique for customized trephination in penetrating keratoplasty. First experimental results in rabbits.

Authors:  Klaus Schmitz; Wolfram Schreiber; Wolfgang Behrens-Baumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-04-17       Impact factor: 3.117

8.  Causes of high astigmatism after penetrating keratoplasty.

Authors:  V P Hoppenreijs; G Van Rij; W H Beekhuis; W J Rijneveld; E Rinkel-van Driel
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

9.  Myopia following penetrating keratoplasty for keratoconus.

Authors:  S J Tuft; F W Fitzke; R J Buckley
Journal:  Br J Ophthalmol       Date:  1992-11       Impact factor: 4.638

10.  [Visual acuity and astigmatism after keratoplasty. Differences between the guided trephine system and motor trephine].

Authors:  A Fejza; A Schafia; U Löw; K Hille; B Seitz
Journal:  Ophthalmologe       Date:  2013-05       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.