Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator.

F E Marchlinski1, B Flores, J M Miller, C D Gottlieb, W C Hargrove.   

Abstract

To determine the relation between the intraoperative defibrillation threshold and successful postoperative termination of induced ventricular fibrillation (VF) with the automatic implantable cardioverter defibrillator (AICD), 33 patients who underwent AICD implantation were studied. The defibrillation threshold, determined after at least 10 seconds of VF, was 5 J in 2, 10 J in 6, 15 J in 10, 20 J in 10 and 25 J in 5 patients. The AICD energy rating on the first discharge was 28 +/- 1.8 J. Defibrillation of induced VF was demonstrated postoperatively in 29 of 33 (88%) patients. The AICD terminated VF postoperatively in all 18 patients with a defibrillation threshold less than or equal to 15 J. Only 11 of the 15 (73%) patients with a defibrillation threshold greater than or equal to 20 J (p less than 0.04) had VF terminated postoperatively. In all 4 patients in whom the AICD failed to terminate induced VF, the energy difference between the AICD rating and the defibrillation threshold was less than or equal to 10 J. Among the 14 patients with a difference of less than or equal to 10 J between the AICD energy rating and the defibrillation threshold, there were no significant differences between the 4 patients with and the 10 without successful VF termination with respect to the duration of VF induced postoperatively or the AICD lead system. In summary, failure to terminate VF with the AICD is not uncommon (27%) when the defibrillation threshold approaches the energy delivering capacity of the AICD.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3414516     DOI: 10.1016/0002-9149(88)90965-4

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

1.  [Single- and dual-chamber ICDs: Are there still significant differences compared to pacemakers with regard to implantation and follow-up?].

Authors:  M Stockburger
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

2.  Incidence and clinical predictors of low defibrillation safety margin at time of implantable defibrillator implantation.

Authors:  Zhongwei Cheng; Mintu Turakhia; Ronald Lo; Anurag Gupta; Paul C Zei; Henry H Hsia; Amin Al-Ahmad; Paul J Wang
Journal:  J Interv Card Electrophysiol       Date:  2012-03-06       Impact factor: 1.900

3.  Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.

Authors:  Yoav Michowitz; Nicolas Lellouche; Tahmeed Contractor; Tara Bourke; Isaac Wiener; Eric Buch; Noel Boyle; Malcolm Bersohn; Kalyanam Shivkumar
Journal:  Europace       Date:  2011-01-19       Impact factor: 5.214

4.  [Influence of waveform and configuration of electrodes on the defibrillation threshold of implantable cardioverter-defibrillators].

Authors:  M Block; D Hammel; G Breithardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

5.  Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention.

Authors:  Sachin Kumar Amruthlal Jain; Hamid Ghanbari; Rayan Hourani; Timothy R Larsen; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2013-01-20       Impact factor: 1.900

Review 6.  Defibrillation Testing During ICD Implantation - Should we or Should we Not?

Authors:  Justin Hayase; Noel G Boyle
Journal:  J Atr Fibrillation       Date:  2017-02-28

7.  Subcutaneous Implantable Cardioverter Defibrillators Implantation Without Defibrillation Threshold Testing: A Single Center Experience.

Authors:  Bandar Al-Ghamdi; Azam Shafquat; Nadiah Alruwaili; Shisamma Emmanual; Mohamed Shoukri; Yaseen Mallawi
Journal:  Cardiol Res       Date:  2017-12-22

8.  Orthostatic increase in defibrillation threshold leading to defibrillation failure and prolonged cardiac arrest in a sitting position: Lessons from a patient's near-fatal experience.

Authors:  Xiaoke Liu; Samuel Asirvatham; G Glenn Kabell
Journal:  HeartRhythm Case Rep       Date:  2016-03-28

9.  Effect of induced ventricular fibrillation and shock delivery on brain natriuretic peptide measured serially following a predischarge ICD test.

Authors:  Marco Budeus; Emanuel Salibassoglu; Anna Maria Schymura; Nico Reinsch; Heinrich Wieneke; Stefan Sack; Raimund Erbel
Journal:  Indian Pacing Electrophysiol J       Date:  2007-10-22

10.  Defibrillation testing of the implantable cardioverter defibrillator: when, how, and by whom?

Authors:  Luis A Pires
Journal:  Indian Pacing Electrophysiol J       Date:  2007-08-01