Literature DB >> 34142502

[Three-dimensional printed drill guide template assisting percutaneous pedicle screw fixation for multiple-level thoracolumbar fractures].

Baifang Zeng1,2, Chao Wu1,2, Tao Li2, Xiangyu Wang2, Qing Shang3.   

Abstract

OBJECTIVE: To evaluate the feasibility and safety of three-dimensional (3D) printed drill guide template-assisted percutaneous pedicle screw fixation for multiple-level thoracolumbar fractures.
METHODS: Clinical data of 19 patients with multilevel thoracolumbar fracture without nerve injury who underwent surgical treatment between May 2017 and January 2019 were retrospectively analyzed. There were 9 males and 10 females and their age ranged from 22 to 63 years, with an average age of 43.6 years. Injury cause included traffic accident injury in 12 cases, and fall from height injury in 7 cases. A total of 40 fractured vertebrae were involved in T 10 to L 3 levels. According to AO classification, there were 29 fractures of type A1, 9 fractures of type A2, and 2 fractures of type A3. According to TANG Sanyuan classification, multiple-segment thoracolumbar fractures were classified as 17 cases of type ⅠA, 1 case of type ⅠB, and 1 case of type ⅡC. The time from injury to operation was 2-6 days, with an average of 3.1 days. The 3D-printed universal drill guide template was used for assisting percutaneous pedicle screw fixation during operation. Intraoperative blood loss, average operation time and fluoroscopy frequency of each screw were recorded. Visual analogue scale (VAS) score was used to evaluate the improvement of low back pain before operation, at 3 days after operation, and at last follow-up. According to the CT at 3 days after operation, the Gertzbein and Robbins scales were used to evaluate the accuracy of screw insertion (the grade A and grade B were regarded as accuracy, the grade A was regarded as excellent of screw insertion). The Cobb angle in sagittal plane of the fracture segment was measured, and the percentage of anterior edge of injured vertebral height was calculated. The consistency of the inclination of bilateral pedicle screws were analyzed postoperatively, and compared the angle of the intraoperative guide plate with the inclination of screw to verify the effectiveness of the guide plate in controlling the inclination.
RESULTS: All the 19 patients completed the operation successfully, and the intraoperative blood loss was 44-67 mL, with an average of 54.3 mL. The average operation time for each screw insertion was 7.3-11.1 minutes, with an average of 9.6 minutes. The average fluoroscopy frequency of each screw insertion was 1.6-2.5 times, with an average of 2.0 times. No spinal cord, nerve root injury, infection, and other complications occurred. All patients were followed up 24-38 months, with an average of 28.7 months. The accuracy of pedicle screws was evaluated by using Gertzbein and Robbins scales: 145 screws were grade A and 11 screws were grade B. The accuracy of screw insertion was 100% and the excellent rate was 92.9%. The CT data at 3 days after operation showed no significant difference in the inclination between the left and right screws in the same vertebral body ( t=0.93, P=0.36). There was no significant difference between the angle of guide plate and the screw inclination ( P>0.05). The VAS score, Cobb angle in sagittal plane, and the percentage of anterior edge of injured vertebral height were significantly improved at 3 days after operation and at last follow-up, and the VAS score was declined at last follow-up compared with 3 days after operation, all showing significant differences ( P<0.05). There was no significant difference in the sagittal Cobb angle and the percentage of anterior edge of injured vertebral height between two postoperative time points ( P>0.05). At last follow-up, no internal fixators were loosened or broken, and all fractures healed well.
CONCLUSION: For the multiple-level thoracolumbar fractures, 3D-printed drill guide template assisting percutaneous pedicle screw fixation can reduce the operation time, intraoperative blood loss, and fluoroscopy frequency and the screw insertion is accurate and has a good reduction effect.

Entities:  

Keywords:  Multiple-level thoracolumbar fractures; drill guide template; minimally invasive technique; pedicle screw; three-dimensional printing

Mesh:

Year:  2021        PMID: 34142502      PMCID: PMC8218182          DOI: 10.7507/1002-1892.202012081

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  15 in total

1.  Multiple level noncontiguous fractures of the spine.

Authors:  Dimitrios S Korres; Petros J Boscainos; Panayiotis J Papagelopoulos; Ioannis Psycharis; George Goudelis; Konstantinos Nikolopoulos
Journal:  Clin Orthop Relat Res       Date:  2003-06       Impact factor: 4.176

2.  [ON COMPLICATED FRACTURES OF THE SPINE].

Authors:  A M KOSVEN
Journal:  Ortop Travmatol Protez       Date:  1965-04

3.  Accuracy of pedicular screw placement in vivo.

Authors:  S D Gertzbein; S E Robbins
Journal:  Spine (Phila Pa 1976)       Date:  1990-01       Impact factor: 3.468

4.  Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation.

Authors:  Tetsuro Ohba; Shigeto Ebata; Koji Fujita; Hironao Sato; Hirotaka Haro
Journal:  Eur Spine J       Date:  2016-03-08       Impact factor: 3.134

Review 5.  AOSpine Classification Systems (Subaxial, Thoracolumbar).

Authors:  Klaus J Schnake; Gregory D Schroeder; Alexander R Vaccaro; Cumhur Oner
Journal:  J Orthop Trauma       Date:  2017-09       Impact factor: 2.512

6.  Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations.

Authors:  Go Yoshida; Koji Sato; Tokumi Kanemura; Toshiki Iwase; Daisuke Togawa; Yukihiro Matsuyama
Journal:  Asian Spine J       Date:  2016-08-16

7.  Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study.

Authors:  Jun-Song Yang; Baorong He; Fang Tian; Tuan-Jiang Liu; Peng Liu; Jia-Nan Zhang; Shi-Chang Liu; Yuan Tuo; Lei Chu; Ding-Jun Hao
Journal:  Med Sci Monit       Date:  2019-04-04

8.  Percutaneous Pedicle Screw Placement Aided by a New Drill Guide Template Combined with Fluoroscopy: An Accuracy Study.

Authors:  Chao Wu; Jiayan Deng; Tao Li; Lun Tan; Dechao Yuan
Journal:  Orthop Surg       Date:  2020-03-04       Impact factor: 2.071

9.  Percutaneous Pedicle Screw Fixation in Thoracolumbar Fractures: Comparison of Results According to Implant Removal Time.

Authors:  Ho-Seok Oh; Hyoung-Yeon Seo
Journal:  Clin Orthop Surg       Date:  2019-08-12

10.  Percutaneous short-segment pedicle instrumentation assisted with O-arm navigation in the treatment of thoracolumbar burst fractures.

Authors:  Peng Yang; Kangwu Chen; Kai Zhang; Jiajia Sun; Huilin Yang; Haiqing Mao
Journal:  J Orthop Translat       Date:  2019-12-05       Impact factor: 5.191

View more
  1 in total

1.  Effect of Minimally Invasive Internal Arch Nailing Surgery on Tissue Traumatic Stress Response in Patients with Vertebral Fractures.

Authors:  Zuzhong Zhou; Zhixiang Chen; Liang Gao; Qizhao Sun; Wen Tang
Journal:  Contrast Media Mol Imaging       Date:  2022-08-16       Impact factor: 3.009

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.