Brian Gullett1, Johanna Aurell2, William Mitchell1, Jennifer Richardson3.
Abstract
Aerial emission sampling of four natural gas boiler stack plumes was conducted using an unmanned aerial system (UAS) equipped with a lightweight sensor-sampling system (the "Kolibri") for measurement of nitrogen oxide (NO), and nitrogen dioxide (NO2), carbon dioxide (CO2), and carbon monoxide (CO). Flights (n=22) ranged from 11 to 24min in duration at two different sites. The UAS was maneuvered into the plumes with the aid of real-time CO2 telemetry to the ground operators and, at one location, a second UAS equipped with an infrared-visible camera. Concentrations were collected and recorded at 1Hz. The maximum CO2, CO, NO, and NO2 concentrations in the plume measured were 10000, 7, 27, and 1.5 ppm, respectively. Comparison of the NO x emissions between the stack continuous emission monitoring systems and the UAS-Kolibri for three boiler sets showed an average of 5.6% and 3.5% relative difference for the run-weighted and carbon-weighted average emissions, respectively. To our knowledge, this is the first evidence of the accuracy performance of UAS-based emission factors against a source of known strength.Entities:
Year: 2021 PMID: 34122665 PMCID: PMC8193813 DOI: 10.5194/amt-14-975-2021
Source DB: PubMed Journal: Atmos Meas Tech ISSN: 1867-1381 Impact factor: 4.176
UAS–Kolibri target analytes and methods.
| Analyte | Instrument, manufacturer data link | Frequency | Cal. gases (ppm) | Cal. gases (ppm) |
|---|---|---|---|---|
| CO2 | SenseAir CO2 Engine K30, NDIR[ | Continuous, 1 Hz[ | 408, 990 | 392, 996, 5890 |
| CO | E2v EC4-500-CO, electrochemical cell | Continuous, 1Hz | 0[ | 0, 9.9, 51.8 |
| NO | NO-D4, electrochemical cell | Continuous, 1Hz | 0, 2.1, 41.4 | 0, 2.1, 40.4 |
| NO2 | NO2-D4, electrochemical cell | Continuous, 1Hz | 0, 2.1, 10.4 | 0, 1.9, 10.4 |
Non-dispersive infrared.
Hz –hertz.
Zero (0) cal. gas: air.
Figure 1.Dow UAS with Kolibri attached to the undercarriage.
CEMS instruments at both Dow locations.
| Gas measured | Midland CEMS | St. Charles CEMS |
|---|---|---|
| O2 | Gaus model 4705 | ABB/Magnos 106 |
| NO | Thermo model 42i-HL | ABB/Limas 11 |
Figure 2.Example of UAS–Kolibri-measured plume concentrations from the St. Charles west boiler. Data reported at 1Hz.
Midland UAS–Kolibri sampling data and emission factors. Time is indicated in US Central Standard Time (GMT−6).
| Date | Flight | Flight time (hh:mm:ss) | NO2 | NO | NO | Avg. CO2 | ||
|---|---|---|---|---|---|---|---|---|
| Up | Down | Total | ||||||
| 11/14/2018 | 1 | 10:29:00 | 10:43:00 | 00:14:00 | 201 | 618 | 819 | 1213 |
| 11/14/2018 | 2 | 11:13:04 | 11:28:28 | 00:15:24 | 186 | 624 | 810 | 1138 |
| 11/14/2018 | 3 | 12:54:17 | 13:08:47 | 00:14:30 | 230 | 659 | 889 | 2948 |
| 11/14/2018 | 5 | 13:27:40 | 13:42:05 | 00:14:25 | 99 | 570 | 669 | 4658 |
| 11/15/2018 | 6 | 10:24:20 | 10:39:30 | 00:15:10 | 61 | 394 | 454 | 3703 |
| 11/15/2018 | 7 | 10:41:36 | 10:52:40 | 00:11:04 | 84 | 397 | 481 | 3983 |
| 11/15/2018 | 8 | 10:55:10 | 11:10:10 | 00:15:00 | 126 | 398 | 524 | 4781 |
| Average | 00:14:13 | 141 | 523 | 664 | 3203 | |||
| SD | 00:01:28 | 65 | 121 | 179 | 1514 | |||
| RSD (%) | 10 | 46 | 23 | 27 | 47 | |||
Flight no. 4 was excluded from calculations as CO was observed, which originated from a cycling second boiler.
St. Charles east stack UAS–Kolibri sampling data and emission factors. Time is indicated in US Central Daylight Time (GMT–5).
| Date | Flight | Flight time (hh:mm:ss) | NO2 | NO | NO | Avg. CO2 | ||
|---|---|---|---|---|---|---|---|---|
| Up | Down | Total | ||||||
| 07/23/2019 | 1 | 09:49:00 | 10:07:00 | 00:18:00 | 1 | 1442 | 1442 | 2305 |
| 07/23/2019 | 2 | 10:12:00 | 10:34:00 | 00:22:00 | 15 | 1461 | 1476 | 2526 |
| 07/23/2019 | 3 | 10:45:00 | 11:08:00 | 00:23:00 | 5 | 1534 | 1539 | 785 |
| 07/23/2019 | 4 | 11:11:00 | 11:31:00 | 00:20:00 | 101 | 1684 | 1785 | 1082 |
| 07/23/2019 | 5 | 11:52:00 | 12:01:00 | 00:09:00 | 107 | 2110 | 2217 | 1923 |
| Average | 00:20:45 | 30 | 1530 | 1560 | 1675 | |||
| SD | 00:02:13 | 47 | 110 | 155 | 869 | |||
| RSD (%) | 11 | 155 | 7.2 | 9.9 | 52 | |||
Flight no. 5 was not included in the average as elevated CO concentrations were detected, likely from other sources in the facility.
St. Charles west stack UAS–Kolibri sampling data and emission factors. Time is indicated in US Central Daylight Time (GMT–5).
| Date | Flight | Flight time (hh:mm:ss) | NO2 | NO | NO | Avg. CO2 | ||
|---|---|---|---|---|---|---|---|---|
| Up | Down | Total | ||||||
| 07/24/2019 | 1 | 07:31:00 | 07:49:00 | 00:18:00 | 25 | 1366 | 1391 | 3221 |
| 07/24/2019 | 2 | 07:52:00 | 08:16:00 | 00:24:00 | 49 | 1263 | 1312 | 3503 |
| 07/24/2019 | 3 | 08:19:00 | 08:38:00 | 00:19:00 | 87 | 1420 | 1507 | 3415 |
| 07/24/2019 | 4 | 09:23:00 | 09:46:00 | 00:23:00 | 65 | 1341 | 1406 | 4509 |
| 07/24/2019 | 5 | 09:49:00 | 10:11:00 | 00:22:00 | 47 | 1296 | 1343 | 4813 |
| 07/24/2019 | 6 | 10:16:00 | 10:36:00 | 00:20:00 | 52 | 1299 | 1351 | 3773 |
| 07/24/2019 | 7 | 10:38:00 | 11:00:00 | 00:22:00 | 53 | 1316 | 1369 | 4194 |
| 07/24/2019 | 8 | 11:51:00 | 12:13:00 | 00:22:00 | 90 | 1460 | 1549 | 3129 |
| 07/24/2019 | 9 | 13:17:00 | 13:39:00 | 00:22:00 | 47 | 1464 | 1511 | 3606 |
| Average | 00:21:20 | 57 | 1358 | 1416 | 3796 | |||
| SD | 00:01:56 | 21 | 74 | 86 | 586 | |||
| RSD (%) | 9 | 36 | 5.5 | 6.0 | 15 | |||
Multi-run average stack CEMS data.
| Midland | St. Charles | ||
|---|---|---|---|
| East boiler | West boiler | ||
| O2 (%) | 8.2 | 4.9 | 4.5 |
| NO | 15.7 | 50.4 | 42.9 |
| Fuel rate | 39.3 × 106 kJ h−1 | 155.2 × 106 kJ h−1 | 177.8 × 106 kJ h−1 |
Comparison of average NO emission factors from CEMS and UAS–Kolibri.
| Run-averaged NO | |||
|---|---|---|---|
| Midland | St. Charles | ||
| East boiler | West boiler | ||
| CEMS | 612 ± 10 | 1555 ± 50 | 1303 ± 29 |
| UAS–Kolibri | 664 ± 179 | 1560 ± 155 | 1416 ± 86 |
| RPD: CEM & UAS–Kolibri, % | 8.2 | 0.3 | 8.3 |