Literature DB >> 34120421

Evaluation of Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters in Obstructive Sleep Apnoea Patients.

Qi Zhe Ngoo1, Nazihatul Fikriah A1, Baharudin A2, Wan Hazabbah Wh1.   

Abstract

PURPOSE: To study the retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters in obstructive sleep apnoea (OSA) patients and their relationship with severity of the disease.
METHODS: A cross-sectional, hospital-based study. Fifty-four OSA subjects and 54 controls were recruited. Candidate that fulfil the criteria with normal ocular examinations then proceed with spectrum domain Cirrus optical coherence tomography examinations. ONH parameters and RNFL thickness were evaluated. Apnoea-hypopnoea index (AHI) of the OSA group were obtained from the medical record.
RESULTS: In OSA, mean of average RNFL thickness was 93.87 µm, standard deviation (SD) = 9.17, p = 0.008 (p < 0.05) while superior RNFL thickness was 113.59 µm, SD = 16.29, p ≤ 0.001 (p < 0.05). RNFL thickness fairly correlate with severity of the disease (AHI), superior RNFL with R = 0.293, R2 = 0.087, p = 0.030 (p < 0.05), and nasal RNFL R = 0.292, R2 = 0.085, p = 0.032. No significant difference and correlation observed on ONH parameters. In control group, mean of average RNFL thickness was 98.96 µm, SD = 10.50, p = 0.008 (p < 0.05) while superior RNFL thickness was 125.76 µm, SD = 14.93, p ≤ 0.001 (p < 0.05).
CONCLUSIONS: The mean of the average and superior RNFL thickness were significantly lower in the OSA group compare to control. Regression analysis showed RNFL thickness having significantly linear relationship with the AHI, specifically involving the superior and nasal quadrant.

Entities:  

Keywords:  Apnea; Apnoea-hypopnoea index; Optic disk; Optic nerve ischemia; Retina

Year:  2021        PMID: 34120421      PMCID: PMC8200590          DOI: 10.3341/kjo.2020.0019

Source DB:  PubMed          Journal:  Korean J Ophthalmol        ISSN: 1011-8942


Obstructive sleep apnoea (OSA) syndrome is characterized by repetitive episodes of upper airway obstruction that occur during sleep, usually associated with a reduction in blood oxygen saturation [1]. The prevalence in Asian populations ranges from 3.57% to 15.5% [2-5]. Over the past two decades various studies have found the link between OSA and systemic diseases such as heart failure [6], diabetes mellitus [7], cognitive impairment [8], and ocular diseases; non arteritic anterior ischaemic optic neuropathy [9-11], glaucoma [12-15], retinal vein occlusion [16] and, central serous chorioretinopathy [17,18]. Chronic oxygen deprivation in OSA may results in activation of the sympathetic pathway, vascular endothelial dysfunction, increased oxidative stress, and inflammation, which may contribute to the initiation and progression of vascular diseases. It is postulated that there is a reduction of ocular perfusion pressure and decreased oxygenation to the optic nerve, causing ischaemia particularly to the sensitive ganglion cell layer resulting in optic neuropathy in OSA patients [19]. Optical coherence tomography (OCT) provides measurement of the thickness of the retinal nerve fiber layer (RNFL) and optic nerve head (ONH) parameters. RNFL thickness and ONH changes may reflect the changes that occur due to hypoxia in OSA. It was found that RNFL thinning was observed in OSA patients [20,21]. Theoretically, the severity of OSA will result in thinner RNFL and ONH parameter changes based on the severity of the hypoxia. However, there are also studies that have not been able to demonstrate the difference in the RNFL and ONH parameters changes in OSA [22,23]. Our study aimed to compare the difference between mean RNFL thickness and ONH parameters in OSA patients and control. We also examined the potential relationship between RNFL thickness and ONH parameters and severity of OSA. We were also taking into consideration other factors that can also contribute to RNFL thinning; age, gender, obesity and smoking, which has not much been addressed in previous studies.

Materials and Methods

This observational cross-sectional study was conducted between May 2015 and February 2017. This was a prospective study. This study obtained ethical approval from the Human Research Ethics Committee of Universiti Sains Malaysia (USM/JEPeM/15050160) and was conducted in accordance with the Declaration of Helsinki for human research. All patients recruited has given their consent to participate in this study and for future publication of data.

Patient selection

Recruitment of OSA patients was conducted in the Department of Ophthalmology. A total of 54 OSA patients were recruited. Both newly diagnosed OSA and known cases on treatment with continuous positive airway pressure therapy (CPAP) were recruited. OSA was diagnosed based on apnoea-hypopnoea index (AHI) on polysomnogram. AHI of ≥5 events/hr was diagnosed of having sleep apnoea. The severity of OSA was divided into mild (AHI 5–15), moderate (16–30), and severe (>30). The control group consists of 54 individuals presented to Ophthalmology clinic without history of sleep apnoea and were selected based on simple random sampling method. Only OSA patients and control subject who have best corrected visual acuity of at least 6 / 12 using the Snellen chart and clear ocular media with refractive error of not more than +/− 6.0 diopters were included in this study. Subject who had a pre-existing optic neuropathy or optic disc hypoplasia, retinopathy, maculopathy, history of trauma or previous ocular surgery, and systemic disease of neurological and demyelinating diseases were excluded. All participants who consented to take part in the study undergo thorough ocular examinations and fundus evaluation via slit lamp biomicroscopy (Topcon, Tokyo, Japan). Intraocular pressure measurement was performed to rule out ocular pathology, which would have precluded participation in the study. Intraocular pressure was assessed with air-puff tonometer to ensure minimal manipulation to the cornea surface in order to prevent artifact on the OCT images. All participants were then subjected for OCT examinations for the right eye.

OCT

OCT examinations was performed using Cirrus OCT (Carl Zeiss Meditec, Dublin, CA, USA) using the fast RNFL scan protocol. The tests were performed by a single and well-trained operator. Only the test or repeated test that yielded signal strength of ≥6 / 10 was taken for interpretations to ensure accuracy of the results. Measurement was taken on right eye which include average RNFL thickness, rim area, disc area, average cup/disc ratio, vertical cup/disc ratio, cup volume and RNFL thickness in four quadrant (superior, inferior, nasal, and temporal).

Statistical analysis

Data analysis was performed using the IBM SPSS Statistics ver. 22 (IBM Corp., Armonk, NY, USA). Descriptive analysis was used for the mean values and standard deviation (SD). All values will be tested for normal distribution in both groups. For demographic data, they will be tested for comparison of age, race and gender. The Student t-test, Pearson chi-square and Fisher exact test were used to analyse the demographic data. All p-values of <0.05 were considered statistically significant. Independent t-test were used to compare the means of ONH parameters and RNFL thickness between study group and control. A p-value of <0.05 was considered as significant. Pearson correlation were used to determine the correlations of ONH parameters and RNFL thickness and the AHI in the OSA group. The strength of association was determined and p-value of <0.05 was considered significant. General guidelines for assigning strength of association by Cohen will be used. Multivariate analysis of covariant (MANCOVA) analysis was done to perform regression analysis of systemic factors such as hypertension, diabetes, dyslipidemia, use of CPAP therapy and ocular factors of axial length and refractive error against the effect in RNFL thickness.

Results

There were a total of 108 participants. Among them 71 were male while 37 of them were female. The age of the participants ranged from 22 to 78 years. OSA patients have higher body mass index, more medical comorbidities and less number of active smoker compared to control subjects in Table 1. There were two OSA patients on CPAP therapy. The mean refractive error of both groups were equal at −0.04. OSA patients has a slighter longer axial length at 23.01. Both groups had normal mean intraocular pressure at 15.3 for OSA patients and 14.7 for control patients. The mean RNFL values of OSA patients and controls are shown in Table 2. We observed a significant difference in the mean of average RNFL thickness with p = 0.008 and superior thickness with p ≤ 0.001 between the control and study group.
Table 1

Demographic data of OSA subjects and control

OSA (n = 54)Control (n = 54)p-value
Mean age (yr)45.69 ± 11.4142.54 ± 13.130.186*
Sex
 Male35 (32.4)36 (33.3)0.839
 Female19 (17.6)18 (16.7)
Race
 Malay48 (44.4)49(45.4)0.750
 Chinese6 (5.6)5 (4.6)
Mean BMI33.04 ± 6.2925.94 ± 3.22<0.001*
Smoking status
 Non-smoker50 (46.3)37 (34.3)0.003
 Smoker4 (3.7)17 (15.7)
Medical problem
 Diabetes mellitus9 (7.4)8 (8.3)0.792
 Hypertension19 (17.8)11 (10.3)0.075
 Dyslipidemia18 (16.8)10 (9.3)0.069
 Heart disease2 (1.9)0 (0.0)0.150
On CPAP therapy2 (1.9)0 (0.0)0.150
Refractive error (diopters)−0.04 ± 0.19−0.04 ± 0.191.000*
Axial length23.01 ± 0.5422.96 ± 0.670.670*
Intraocular pressure15.30 ± 0.4214.70 ± 0.390.710*

Values are presented as number or mean ± standard deviation; The mean RNFL values of OSA patients and controls are shown in Table 2; We observed a significant difference in the mean of average RNFL thickness with p = 0.008 and superior thickness with p ≤ 0.001 between the control and study group.

OSA = obstructive sleep apnoea; BMI = body mass index; CPAP = continuous positive airway pressure therapy.

Independent t-test;

Pearson chi-square test;

Fisher exact test.

Table 2

Comparing mean of RNFL thickness of right eye in OSA patient and control

RNFL thickness (μm)OSA (n = 54)Control (n = 54)tMeans difference95% confidence intervaldfp-value
Average93.87 ± 9.1798.96 ± 10.502.6865.0931.333–8.852104.120.008*
Superior113.59 ± 16.29125.76 ± 14.934.04712.1676.206–18.127105.20<0.001*
Inferior123.06 ± 17.79126.80 ± 16.021.1483.741−2.719–10.200104.870.253
Nasal69.65 ± 9.6171.04 ± 11.210.6911.389−2.595–5.373103.590.490
Temporal67.87 ± 14.2072.09 ± 12.781.6244.222−0.932–9.376104.850.107

Values are presented as mean ± standard deviation unless otherwise indicated.

RNFL = retinal nerve fiber layer; OSA = obstructive sleep apnoea.

Independent t-test.

MANCOVA was performed to look into the possibilities of diabetes mellitus, hypertension, dyslipidemia and CPAP therapy becoming covariates affecting our results in Table 3. The MANCOVA analysis showed that the age, body mass index, smoking, diabetes mellitus, hypertension, dyslipidemia and CPAP therapy were not the confounder affecting the thickness of RNFL in our study. For ocular factors such as axial length and refractive error, we found out that they were not confounding factors affecting RNFL thickness in our study. In our statistical analysis, all the independent variables were tested for multicollinearity and was found to be not significant.
Table 3

Multivariate analysis of covariant of right eye RNFL thickness in obstructive sleep apnoea subject and control

EffectValueFHypothesis dfError dfPartial eta squaredSignificance
Age0.9100.90110.0091.000.9000.536
BMI0.9500.47710.0091.000.5000.901
Smoking0.8411.72210.0091.000.1590.088
Diabetes mellitus0.9210.70510.0091.000.0720.718
Hypertension0.9010.99610.0091.000.0990.453
Dyslipidemia0.8271.90010.0091.000.1730.055
CPAP therapy0.4251.42210.0091.000.1250.652
Refractive power−0.0210.37710.0091.000.0040.426
Axial length0.8500.82210.0091.000.5000.567

RNFL = retinal nerve fiber layer; BMI = body mass index; CPAP = continuous positive airway pressure therapy.

Table 4 showed that there was no significant difference between mean of ONH parameters of OSA subjects and control.
Table 4

Comparing mean of ONH parameters of right eye in OSA patient and control

ONH parametersOSA (n = 54)Control (n = 54)tMeans difference95% confidence intervaldfp-value*
RNFL symmetry (%)87.07 ± 8.1883.67 ± 9.921.9473.407−6.879–0.640102.300.054
Rim area1.303 ± 0.2141.346 ± 0.2321.0020.043−0.042–0.128105.340.319
Disc area2.023 ± 0.3312.123 ± 0.4211.3730.100−0.044–0.244100.460.173
Average CDR0.567 ± 0.1080.563 ± 0.1630.1460.004−0.567–0.04991.8700.884
Vertical CDR0.522 ± 0.1190.524 ± 0.1620.0610.002−0.053–0.05697.400.952
Cup volume0.170 ± 0.1190.214 ± 0.1551.6360.436−0.009–0.096106.000.105

Values are presented as mean ± standard deviation unless otherwise indicated.

ONH = optic nerve head; OSA = obstructive sleep apnoea; RNFL = retinal nerve fiber layer; CDR = cup to disc ratio.

Independent t-test.

Table 5 showed that there was a significantly fair negative correlation between AHI and RNFL thickness among the subject in the OSA group in the superior R = 0.295, R2 = 0.087, r = −0.295, p = 0.030 (p < 0.05) and nasal quadrant R = 0.292, R2 = 0.085, r = − 0.292, p = 0.032 (p < 0.05). However, none of the ONH parameters had significant linear relationship with the AHI among subjects in the OSA group.
Table 5

Correlation between the RNFL thickness of right eye and apnoea-hypopnoea index in the obstructive sleep apnoea patients

RR2Frp-value
RNFL thickness
 Average0.2280.0522.845−0.2280.980
 Superior0.2950.0874.962−0.2950.030*
 Inferior0.0430.0020.097−0.0430.756
 Nasal0.2920.0854.852−0.2920.032*
 Temporal0.1020.0100.548−0.1020.463
ONH parameters
 Rim area0.0290.0010.0430.0290.836
 Disc area0.2480.0623.4100.2480.070
 Average CDR0.2460.0603.3480.2460.073
 Vertical CDR0.2530.0643.5680.2530.064
 Cup volume0.0530.0030.1470.0530.703

RNFL = retinal nerve fiber layer; ONH = optic nerve head; CDR = cup to disc ratio.

Simple linear regression and Pearson correlation (p < 0.05).

Discussion

OSA is a sleep-related condition which causes a decrease in the arterial oxygen saturation and a rise in the carbon dioxide saturation during sleep. Many authors hypothesized that chronic oxygen deprivation is responsible for the underlying pathophysiology of the disease, resulting in generalized sympathetic activation and metabolic dysregulation, subsequently leading to the increase risk of cardiovascular and cerebrovascular diseases [24-26]. In ocular tissues, the same pathophysiology occurs, causing a reduction of ocular perfusion pressure and decreased and ischaemia to the ganglion cell layer, leading to optic neuropathy. Our result showed a significant difference in the average RNFL thickness with a mean difference of 5.093, p = 0.008 (<0.05) and superior thickness with a mean difference of 12.167, p < 0.001 (p < 0.05) between the control and study group. This is similar to the results of Sagiv et al. [21] who found significant thinning of RNFL in all quadrants except nasally in moderate to severe OSA subjects and Lin et al. [27] found significant thinning in the superior quadrant. Likewise, similar findings were also reported by Kargi et al. [28]. Our findings are in contrast to the findings of Adam et al. [22] and Nowak et al. [23], who found no significant changes in RNFL thickness in OSA. Kargi et al. [28] demonstrated that decreased ocular perfusion secondary to hypoxia and vasospasm may lead to RNFL thinning. Although many researchers found a relatively thinner RNFL in OSA subjects, the quadrant involved were not similar. We think that this is due to the possibility that some sub-clinical papilledema may actually happen in the early part of the disease [29]. When the oedema of the ganglion cell layer resolved, the resolution of the oedema may not be symmetrical or occurred at the same time in all quadrant, hence asymmetrical thinning of the quadrant RNFL happen. We went a step further by performing a multivariate analysis of covariant to determine whether our significant result was also contributed by any confounding factor. It has been shown in previous study that RNFL thickness was reduced in diabetes mellitus, hypertension, dyslipidemia, increased body mass index, age, smoking habit and CPAP therapy [30-32]. In our study, any of the above factors were not found to be a confounder. For ocular parameters, such as refractive error and axial length, our study analysis showed that they were not confounding factors as well. We found no significant difference with regards to ONH parameters between OSA and control. This is similar to the study by Lin et al, who found no significant differences of ONH parameters between OSA and controls. Contrary to the findings by Casas et al. [20], they found larger disc area in her OSA group of patients while Huseyinoglu et al. [31] found that nerve head volume in his mild and moderate OSA group had higher reading compared to control group and decrease in severe group compare to control. They postulated that this probably happen due to optic disc had already pass-through stage of subtle oedema in the mild and moderate group and move into the stage of reduction of RNFL thickness with axonal loss in severe group. We have almost half of our sample in the severe group, therefore the supposedly increase volume in the mild and moderate group had been compensated by the reduction in the thickness in our severe group, hence probably normalising or reducing our mean difference. Our regression analysis showed a fair significant negative direct linear relationship between the RNFL thickness in the superior and nasal quadrant with the AHI. For every increment of 1 AHI index, the decrement of 0.295 micron occur in the superior quadrant and 0.292 micron in the nasal quadrant. These results are similar to studies by Lin et al. [27], Moghimi et al. [33], and Sagiv et al. [21] who also found correlation between the nasal quadrant and severity, but they used respiratory disturbance index instead of AHI [34]. However, in our study, there are no significant correlations and associations between any of the ONH parameters and AHI. We concluded that abnormalities in ONH parameters occur secondary to RNFL loss; thus, RNFL changes may be a more sensitive marker of hypoxia in OSA compared to the optic changes of nerve head parameters. Due to limited number of patient available to participate in our study, this study also include patients who were newly diagnosed as well as those who were already on treatment with CPAP. Therefore, the result may not be as accurate as taking only a newly diagnosed OSA, as the RNFL thickness had also been shown to be decreasing after treatment with CPAP therapy [33]. It was postulated to occur secondary to CPAP therapy causes increased in intraocular pressure at night [35,36], therefore, these group of patients may have higher risk of developing glaucoma. In future, this limitation may be overcome by taking only the newly diagnosed OSA before the initiation of any treatment. We are unable to determine the exact duration of the OSA. However, majority of our subjects were diagnosed to have OSA within 2 years of diagnosis when we performed OCT examination on them. It is possible that the greater the severity and longer duration of the hypoxia, the greater the RNFL alterations. Furthermore, a referral bias could be present since patients were referred for snoring and, therefore, they might not be representative of the entire OSA population which might be mostly undiagnosed. It is possible that the greater the severity with longer duration of the hypoxia will result in greater the RNFL alterations. Our sample size of 54 patients was not enough to represent OSA population as a whole and to overcome the short duration of diagnosis of the patients. In future cohort, we planned to extend the study to 5 years to include patients with longer duration of OSA, therefore enabling us to include the duration as part of the analysis. Our study is a cross-sectional, prospective study. There were no comparison done or follow up to actually look at the changes in all of the studied parameters over time. We suggest that in future, another study to be done on these patients in order to evaluate the possible changes on the RNFL thickness as well as ONH parameters in these patients. Our study is limited by the presence of medical problem in our control. We were unable to fully exclude those with medical problem from becoming our control group. Therefore, the result may be confounded by the presence of these factors. We suggest that if similar study will be carried out in the future should, the control group should be selected among those without medical problem. Our study showed that OSA patients have reduced RNFL thickness in the average and superior quadrant compared to controls. A significant fair direct negative correlation exists between superior quadrant as well as nasal quadrant of RNFL with the severity of the disease, measured by the AHI. Further evaluations and long term follow up may be needed in future in order to monitor the progression of RNFL thinning in this group of patients.
  35 in total

Review 1.  Obstructive sleep apnea and cardiovascular disease: role of the metabolic syndrome and its components.

Authors:  Girardin Jean-Louis; Ferdinand Zizi; Luther T Clark; Clinton D Brown; Samy I McFarlane
Journal:  J Clin Sleep Med       Date:  2008-06-15       Impact factor: 4.062

2.  Retinal and optic nerve evaluation by optical coherence tomography in adults with obstructive sleep apnea-hypopnea syndrome (OSAHS).

Authors:  Paula Casas; Francisco J Ascaso; Eugenio Vicente; Gloria Tejero-Garcés; María I Adiego; José A Cristóbal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-03       Impact factor: 3.117

3.  Sympathetic over activity in the etiology of hypertension of obstructive sleep apnea.

Authors:  Eugene C Fletcher
Journal:  Sleep       Date:  2003-02-01       Impact factor: 5.849

4.  Excessive daytime sleepiness among Japanese public transportation drivers engaged in shiftwork.

Authors:  Shoichi Asaoka; Kazuyoshi Namba; Satoru Tsuiki; Yoko Komada; Yuichi Inoue
Journal:  J Occup Environ Med       Date:  2010-08       Impact factor: 2.162

5.  Papilledema and obstructive sleep apnea syndrome.

Authors:  V A Purvin; A Kawasaki; R D Yee
Journal:  Arch Ophthalmol       Date:  2000-12

Review 6.  Glaucoma and obstructive sleep apnoea syndrome.

Authors:  Omar Faridi; Sung Chul Park; Jeffrey M Liebmann; Robert Ritch
Journal:  Clin Exp Ophthalmol       Date:  2012-04-24       Impact factor: 4.207

7.  Prevalence of glaucoma in patients with obstructive sleep apnoea--a cross-sectional case-series.

Authors:  R E Bendel; J Kaplan; M Heckman; P A Fredrickson; S-C Lin
Journal:  Eye (Lond)       Date:  2007-05-04       Impact factor: 3.775

8.  Cholesterol affects retinal nerve fiber layer thickness in patients with multiple sclerosis with optic neuritis.

Authors:  A Kardys; B Weinstock-Guttman; M Dillon; M W Masud; N Weinstock; N Mahfooz; J K Lang; A Weinstock; N Lincoff; R Zivadinov; M Ramanathan
Journal:  Eur J Neurol       Date:  2013-04-14       Impact factor: 6.089

9.  Obstructive sleep apnea in patients with central serous chorioretinopathy.

Authors:  Patrik Kloos; Irene Laube; Adelheid Thoelen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-06-11       Impact factor: 3.117

10.  Impact of Obstructive Sleep Apnoea on Heart Failure with Preserved Ejection Fraction.

Authors:  Takuo Arikawa; Shigeru Toyoda; Akiko Haruyama; Hirohisa Amano; Shu Inami; Naoyuki Otani; Masashi Sakuma; Isao Taguchi; Shichiro Abe; Koichi Node; Teruo Inoue
Journal:  Heart Lung Circ       Date:  2015-10-18       Impact factor: 2.975

View more
  1 in total

1.  Assessment of the Effectiveness of Obstructive Sleep Apnea Treatment Using Optical Coherence Tomography to Evaluate Retinal Findings.

Authors:  Gloria Tejero-Garcés; Francisco J Ascaso; Paula Casas; Maria I Adiego; Peter Baptista; Carlos O'Connor-Reina; Eugenio Vicente; Guillermo Plaza
Journal:  J Clin Med       Date:  2022-02-03       Impact factor: 4.241

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.