| Literature DB >> 34119358 |
Parijat Das1, Sudipto Mondal2, Soumik Pal2, Samadrita Roy2, Anju Vidyadharan2, Rajneesh Dadwal2, Sanjay Bhattacharya2, Deepak Kumar Mishra3, Mammen Chandy4.
Abstract
BACKGROUND: The selection of appropriate kit and PCR equipment for the detection of SARS CoV-2 is critically important in view of many options available in the diagnostic market. Since last year many molecular products are available for COVID-19 diagnostics., some of these diagnostics have become commercially available for healthcare workers and clinical laboratories. However, the diagnostic technologies have specific limitations and reported several false-positive and false-negative cases, especially during the early stages of kit development and use. The current article addresses these and other relevant questions important to the medical microbiologists running or aspiring to run COVID diagnostic services using PCR and related technologies.Entities:
Keywords: CBNAAT; COVID; Isothermal amplification; RT-PCR; SARS-CoV-2
Mesh:
Year: 2021 PMID: 34119358 PMCID: PMC8189747 DOI: 10.1016/j.ijmmb.2021.05.012
Source DB: PubMed Journal: Indian J Med Microbiol ISSN: 0255-0857 Impact factor: 0.985
Country wise summary of COVID RT-PCR protocols published by public health and research labs.
| Country | Institute | Gene targets | Reference |
|---|---|---|---|
| Charité | RdRP, E, N | ||
| China CDC | ORF1ab and N | ||
| HKU | ORF1b-nsp14, N | ||
| National Institute of Infectious Diseases, | Pancorona and multiple targets, | ||
| National Institutes of Health | N | ||
| Principal Scientific Adviser to the Government of India | RdRp, E and N. | ||
| US CDC | Three targets in N | ||
| Institut Pasteur, Paris | Two targets in RdRP |
CDC, Centres for Disease Control and Prevention; ORF, open reading frame.
Principal Scientific Adviser to the Government of India; update effective from April 11, 2020.
CDC updates effective from March 15, 2020.
List of conventional SARS CoV-2 RT-PCR kits.
| Manufacturer Details | Country of manufacturer | Regulatory status | Target Gene | Single tube multiplex/Multitube multiplex | PCR time | Instrument Compatibility | Pack Size | Reporter dye |
|---|---|---|---|---|---|---|---|---|
| International Manufacturer | ||||||||
| Altona Diagnostics | Germany | USA FDA EUA; CE-IVD | E gene, S gene with IC | SINGLE | 2.15 h | ABI 7500, Roche LightCycler® 480, RGQ, QuantStudio 5 R, CFX96, | 384 Rxn | FAM, JOE, Cy5 |
| Seegene | South Korea | USA FDA EUA; CE-IVD; | E gene, RdRP gene, N gene with IC | SINGLE | 1.30 h | CFX 96 (BioRad) | 50/100 Rxn | FAM, CalRed 610, Quasar 670, HEX |
| SD Biosensor | Republic of Korea | USA EUA; CE-IVD; | ORF1ab,E gene with IC | SINGLE | 1.30 h | LightCycler 480 or CFX96Dx System, ABI 7500 | 96 Rxn | FAM, JOE/VIC/HEX, Cy5 |
| BGI | China | USA EUA; CE-IVD; | ORF1ab region, β-Actin | SINGLE | 3 h | ABI 7500,Roche LightCycler 480,QuantStudio 5 | 50 Rxn | FAM/VIC (NOTspecified) |
| ABI (Applied bio systems) | USA | No web information | ORF1ab,S,N with IC | SINGLE | 1.10hrs | ABI 7500,QuantStudio 5 | 96 Rxn | FAM, VIC, ABY, JUN |
| ADT Biotech SdnBhd | Malaysia | RUO | E gene, RdRP gene with IC | SINGLE | 2.15 h | Rotor-Gene 3000/6000,Rotor-Gene Q5/6 plexPlatform,ABI 7500,CFx96 | 48 Rxn | FAM,HEX |
| OSANG Health Care | Republic of Korea | FDA EUA,CE-IVD | E, RdRP, N with IC | SINGLE (Single gene) | 2.15 h | CFX96Dx System, ABI 7500 | 100 Rxn | FAM,TexasRed,JOE/VIC,Cy5 |
| Gene Matrix | California, USA | USA FDA EUA | N, RdRP | SINGLE | 3 h | CFX96Dx, ABI 7500 | 96 Rxn | FAM, HEX |
| Accelerate Technologies Pte Ltd | Singapore | RUO | Not Specified | SINGLE | 2.30 h | CFX96Dx | 200 Rxn | FAM, HEX |
| Daan Gene Co. Ltd., | China | CE-IVD; China | ORF1ab, N | SINGLE | 1.30 h | LightCycler480 Ⅱ, ABI 7500 | 24/48/96 Rxn | FAM,VIC,Cy5 |
| JN MedsysPte Ltd, | Singapore | USA EUA, CE IVD Philippines | N1, N2 and RNase P | SINGLE | 1.35 Hrs | QS3 | 100 RX | FAM |
| Kogene Biotech | Korea | CE-IVD | E, RdRP | TWO | No web information | CFX 96, ABI 7500, PowerAmp 96 | 50/100Rxn | FAM, JOE (VIC/HEX) |
| LabGenomics, | South Korea | USA FDA EUA | E, RdRP | TWO | 2.30Hrs | CFX 96, ABI 7500 | 100 RX | :FAM and HEX (VIC), Cy5 |
| OSANG Health Care | South Korea | CE IVD, USA FDA EUA | E, RdRP, N | SINGLE | 2 Hrs | CFX 96, ABI 7501 | 100 RX | FAM,Texas Red, JOE/VIC,Cy5 |
| Primer Design, | UK | CE IVD/RUO∗ | N, RdRP | SINGLE | No web information | Roche LightCycler 480 II,CFX 96, ABI 7500 | 96 Rxn | FAM, VIC/HEX |
| Sansure Biotech Inc., | China | CE IVD, USA FDA EUA | ORF1ab, N | SINGLE | 2.30 Hrs | ABI 7500 | 24/48 Rxn | FAM, ROX, Cy5 |
| ZyBioInc, | China | USA FDA EUA | No web information | No web information | No web information | No web information | 32 Rxn | No web information |
| MY LAB | India | DGCI India | RdRp, E gene | THREE | 2 h | ABI 7500, RGQ, QS 5 R, CFX instrument (Bio-Rad) | 50 and 100 Rxn | FAM (RdRP) VIC/HEX (E and RNAseP) |
| KILPEST (BLACKBIO) | India | DGCI India | E, RdRP, N with IC | SINGLE/TWO | 1.10hrs | ABI 7500, RGQ, QuantStudio 3 | 100 Rxn | FAM, HEX |
| Helini Biomolecules | India | CE IVD, ICMR | RdRp and ORF gene | SINGLE | 1.35 Hrs | Agilent, Bio-Rad, Roche Lightcycler-96, RocheZ480/Cobas-480, ABI 7500, | 25/50/100 Rxn | FAM & HEX & Cy5 |
| GCC Biotech | India | ICMR | RdRP gene, N gene with IC | SINGLE | 1.35 Hrs | RGQ,QuantStudio 3 | 100/200/500 Rxn | No web information |
Isothermal DNA Amplification Technologies compared to PCR (a non isothermal method).
| Property | PCR | NASBA | SMART | SDA | RCA | LAMP | HDA | SPLA |
|---|---|---|---|---|---|---|---|---|
| + | + | + | + | + | + | + | + | |
| + | + | + | + | + | + | + | + | |
| 94, 55–60, 72 | 37–42 | 41 | 37 | 37 | 60–65 | Room temp, 37, 60-65 | 45,50 | |
| Simple | Simple | Complex | Complex | Simple | Complex | Simple | Simple | |
| 1 | 2–3 | 2–3 | 2 | 1 | 1 | 2 | 3 | |
| + | + | – | – | – | – | + | – | |
| Gel electrophoresis, Real-time | Gel electrophoresis, Real-time, ECL | Gel electrophoresis, Real-time, | Gel electrophoresis, Real-time, | Gel electrophoresis, Real-time, | Gel electrophoresis, Real-time, turbidity | Gel electrophoresis, Real-time, ELISA | Bioanalyzer |
• PCR: polymerase chain reaction; NASBA-nucleic acid sequence based amplification; SMART- Simple Method to Amplify RNA Targets; SDA-strand displacement amplification; RCA-recombinase polymerase amplification; LAMP- loop mediated isothermal amplification; HDA- Helicase Dependent Amplification; SPLA - Single-primer-limited amplification.
Potential reasons for COVID RT-PCR test discrepancy.
Differences in pre-analytical variables: Sample collection kit Viral transport media Swab type How diligently the sample is collected Sometimes the collector is afraid to collect sample properly; sometime the patient gags or does not cooperate; sometimes the tonsil and posterior pharyngeal wall or mid inferior portion of inferior turbinate cannot be easily reached) Sample transport conditions Sample storage conditions Timing of the test (samples taken in relation to symptom; sample taken in relation to sub-clinical infection duration) Differences in analytical variables: RNA extraction method Spin column extraction Magnetic bead extraction Automated RNA extraction instrument and kit type PCR kit used: we use three different kits: Seegene, Altona, True PCR; Every kit may have differences in Genes detected Analytical sensitivity (Limit of detection) Clinical sensitivity and specificity Differences in Post analytical variables: CT cut-off used to call positive (True PCR: 35; Seegene 40; Altona 45) Number of genes and type of genes for calling a sample positive Sometimes the borderline cases just over the cut-off may be called positive or vice versa |
List of cartridge-based molecular test for detection of COVID-19.
| Manufacturer | Test kit | Diagnostic equipment | Instrument throughput | Separate Viral RNA extraction required? | COVID 19 viral gene targets | Test per kit | Time to results |
|---|---|---|---|---|---|---|---|
| Moderate Complexity and available to Hospital Laboratories | |||||||
| BioFire | 1) Film Array 2.0 | Low | No | 3 | 6-test kit or 30-test kit | 0.83 h | |
| ePlex SARSCoV-2 Test | GenMarkePlex | Low | No | Not disclosed | 12 Tests | 2 h | |
| Simplexa | LIAISON MDx | Low | No | 2 | 24 Tests | 1.5 h | |
| cobas SARSCoV-2 | Options: | High | No | 2 | 192 Tests | 3.5 h | |
| Respiratory | QIAstat-Dx | Low | No | 2 | 6 tests | 1.10 h | |
| BioGX SARSCoV-2 | BD Max | Low to Moderate | No | 2 | 24tests | 3 h | |
| ARIES SARSCoV-2 | Luminex ARIES | Low | No | 2 | 24tests | 2 h | |
| Accula SARSCov-2 Test | Low | No | 1 | 25 Tests | 0.5 h | ||
| Xpert Xpress | Low to High | No | 2 | 10 Tests | 0.75 h | ||
| Abbott | ID NOW | ID NOW | Low | No | 1 | 24 Tests | 0.25 h |
| Panther Fusion | Panther | Moderate to High | No | 2 | 96 Test | 2.5 h | |
| NeuMoDx | Options: | Moderate to High | No | 2 | 96 Test | 1.5 h | |