Literature DB >> 3411055

Ultrasonic backscatter from flowing whole blood. I: Dependence on shear rate and hematocrit.

Y W Yuan1, K K Shung.   

Abstract

Previous results show that ultrasonic backscatter from red blood cells (RBCs) suspended in saline is a function of hematocrit and frequency and that it can be affected by flow disturbance. The experimental data agree well with the theories. In the present article, results on ultrasonic backscatter from flowing whole blood are reported. Studies have been conducted on porcine, bovine, and human blood. Ultrasonic backscatter of flowing whole blood differs from that of RBC suspensions in that it is shear-rate dependent, which means that it is a function of spatial position of the blood in the flow conduit. Moreover, the results indicate that it is also species dependent. This behavior can be readily understood when red cell aggregation is considered.

Entities:  

Mesh:

Year:  1988        PMID: 3411055     DOI: 10.1121/1.397238

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  12 in total

1.  A system-based approach to modeling the ultrasound signal backscattered by red blood cells.

Authors:  I Fontaine; M Bertrand; G Cloutier
Journal:  Biophys J       Date:  1999-11       Impact factor: 4.033

2.  Simulation of ultrasound backscattering by red cell aggregates: effect of shear rate and anisotropy.

Authors:  Isabelle Fontaine; David Savéry; Guy Cloutier
Journal:  Biophys J       Date:  2002-04       Impact factor: 4.033

3.  Assessment of blood echogenicity as an alternative measure to erythrocyte sedimentation rate.

Authors:  T Kallio
Journal:  BMJ       Date:  1991-07-13

4.  Comparison between minimum lumen cross-sectional area and intraluminal ultrasonic intensity analysis using integrated backscatter intravascular ultrasound for prediction of functionally significant coronary artery stenosis.

Authors:  Hironori Takami; Shinjo Sonoda; Yoshitaka Muraoka; Toshiya Miura; Akiyoshi Shimizu; Reo Anai; Yoshinori Sanuki; Tetsu Miyamoto; Yasushi Oginosawa; Yoshihisa Fujino; Yuki Tsuda; Masaru Araki; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2018-07-30       Impact factor: 2.037

5.  Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties.

Authors:  Alvin I Chen; Max L Balter; Melanie I Chen; Daniel Gross; Sheikh K Alam; Timothy J Maguire; Martin L Yarmush
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

6.  Microfluidic-based speckle analysis for sensitive measurement of erythrocyte aggregation: A comparison of four methods for detection of elevated erythrocyte aggregation in diabetic rat blood.

Authors:  Eunseop Yeom; Sang Joon Lee
Journal:  Biomicrofluidics       Date:  2015-04-03       Impact factor: 2.800

7.  Effect of erythrocyte aggregation on hematocrit measurement using spectral-domain optical coherence tomography.

Authors:  Xiangqun Xu; Lingfeng Yu; Zhongping Chen
Journal:  IEEE Trans Biomed Eng       Date:  2008-12       Impact factor: 4.538

8.  Transesophageal echocardiographic determinants of embolism in nonrheumatic atrial fibrillation.

Authors:  R Mitusch; V Lange; U Stierle; B Maurer; A Sheikhzadeh
Journal:  Int J Card Imaging       Date:  1995-03

9.  Three-dimensional Transesophageal Echocardiography Demonstration of Left Atrial Appendage Echocontrast Regression after 6 Months Therapy with Dabigatran and not with Warfarin.

Authors:  Domenico Vestito; Delia Desantis; Paolo Colonna
Journal:  J Cardiovasc Echogr       Date:  2016 Apr-Jun

10.  Quantitative Assessment of First Annular Pulley and Adjacent Tissues Using High-Frequency Ultrasound.

Authors:  Yi-Hsun Lin; Tai-Hua Yang; Shyh-Hau Wang; Fong-Chin Su
Journal:  Sensors (Basel)       Date:  2017-01-07       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.