| Literature DB >> 34092217 |
Attila G Sipos1, Krisztina Pákozdy1, Szilvia Jäger2, Kindra Larson3, Peter Takacs3, Bence Kozma4.
Abstract
BACKGROUND: The basic principle of vaginal laser therapy is the rejuvenation of the affected tissue. Zinc and copper are essential nutritional trace elements and have a key role in connective tissue homeostasis. We aimed to investigate the effect of vaginal, fractional CO2 laser treatment on cervicovaginal lavage (CVL) zinc and copper levels.Entities:
Keywords: CO2 laser; Cervicovaginal fluid; Copper; Fractional laser; Vagina; Zinc
Year: 2021 PMID: 34092217 PMCID: PMC8180012 DOI: 10.1186/s12905-021-01379-1
Source DB: PubMed Journal: BMC Womens Health ISSN: 1472-6874 Impact factor: 2.809
The operating parameters of ICP-OES 5100 (Agilent Technologies)
| ICP-OES operating parameters | |
|---|---|
| Repetition | 3 |
| Pump speed | 15 rpm |
| Uptake time | 20 s, fast pump |
| Rinse time | 30 s, fast pump |
| Read time | 10 s |
| RF energy | 1.20 kW |
| Stabilization time | 7 s |
| View mode | SVDV |
| view height | 0 mm |
| Nebulizer gas | 0.70 l/min |
| Plasma gas | 12.0 l/min |
Clinical and demographic characteristics
| Variable | Mean ± SD |
|---|---|
| Number of women, N | 29 |
| Age (years) | 58.24 ± 8.60 |
| Gravida | 2.38 ± 1.32 |
| Para | 1.90 ± 0.77 |
| Last menstrual period (years) | 11 ± 8 |
| Body Mass Index (kg/m2) | 26.40 ± 5.06 |
Vaginal Health Index (VHI) and Visual Analog Scale (VAS) for vaginal dryness before and 4 weeks after the 1st, 2nd, and 3rd treatment with CO2 vaginal laser
| CO2 laser treatment | P-value | ||||||
|---|---|---|---|---|---|---|---|
| Baseline | After 1st | After 2nd | After 3rd | Baseline versus 1st | Baseline versus 2nd | Baseline versus 3rd | |
| VHI | 13.03 ± 4.49 | 15.55 ± 4.35 | 17.79 ± 4.57 | 19.38 ± 4.39 | < 0.01 | < 0.01 | < 0.01 |
| VAS | 6.59 ± 2.86 | 4.17 ± 3.02 | 2.45 ± 2.43 | 1.41 ± 1.94 | < 0.01 | < 0.01 | < 0.01 |
Cervicovaginal lavage zinc and copper levels before and 4 weeks after the 1st, 2nd, and 3rd treatment with CO2 vaginal laser
| CO2 laser treatment | P-value | ||||||
|---|---|---|---|---|---|---|---|
| Baseline | After 1st | After 2nd | After 3rd | Baseline versus 1st | Baseline versus 2nd | Baseline versus 3rd | |
| Zinc (mg/L) | 0.06 ± 0.04 | 0.07 ± 0.05 | 0.10 ± 0.09 | 0.07 ± 0.07 | NS | < 0.01 | NS |
| Copper (mg/L) | 0.006 ± 0.006 | 0.006 ± 0.008 | 0.006 ± 0.007 | 0.005 ± 0.005 | NS | NS | NS |