The truth is in the eye of the beholder; opportunistic pathogens in the dental unit.

M A Hoogenkamp1, A M G A Laheij2, J J de Soet3.   

Abstract

Entities:  

Year:  2021        PMID: 34087259      PMCID: PMC8758131          DOI: 10.1016/j.jhin.2021.05.014

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


× No keyword cloud information.
Infection control measures in the dental office are meant to reduce the risk of cross-contamination. A known source of cross-contamination is the dental unit. This medical device is prone to biofilm formation as the potable water used to cool the rotating instruments and ultrasonic devices contains micro-organisms. Once adhered to the tubing surface, these waterborne micro-organisms form a matrix-encapsulated biofilm. This biofilm subsequently acts as a scaffold for the incorporation of bloodborne pathogens, introduced into the unit due to failing anti-retraction valves [1]. When released from the biofilm, these water- and bloodborne micro-organisms may be aerosolized and subsequently inhaled or ingested by patients and dental staff. Immunocompromised patients run a risk from exposure to these micro-organisms. With the current COVID-19 pandemic, a new population of patients has arisen with long-term pulmonary complications, making prevention of bacterial and fungal aerosol exposure of prime importance [2,3]. To prevent exposure to these micro-organisms, infection control protocols are in place. Within the Netherlands, infection control guidelines are issued to ensure microbiological water quality in the dental unit: dentists perform a bi-annual risk assessment, based on an effluent water sample [4]. This sample, collected 30 s post flushing, is analysed using heterotrophic plate counts (HPC) to determine the number of viable bacteria. Units are deemed safe to use if the HPC are <100 cfu/mL. Additional testing for legionella has to be performed when >104 cfu/mL are detected and practices must halt patient treatment when >100 cfu/L Legionella spp. are found. In a recent study on 213 dental units, we showed that 84 units contained HPC <100 cfu/mL, while 54 units contained >104 cfu/mL [5]. Additional to the regular effluent water sample, a ‘proxy’ biofilm sample was taken. This sample, taken after an overnight stagnancy period and prior to any flushing or hygiene measures, was analysed using molecular techniques. We found that, besides bacteria, 98% and 43% of the units contained fungal and amoeba DNA, respectively. Of the units containing HPC <104 cfu/mL, 65% contained >2000 genomic units per litre Legionella spp. Even units without detectable HPC contained considerable concentrations of Legionella spp. Microbiome analysis revealed the presence of bacterial genera frequently associated with community-acquired pneumonia [5]. The risk assessment for dental units is primarily based on the HPC and less on the presence of (opportunistic) pathogens. Hydrodynamic principles, however, drive a favourable outcome of the water quality. During use, the fluid column in the lumen of the tubing is replaced with relatively clean input water, while creating a hydrodynamic boundary layer on the tubing wall with little or no exchange of micro-organisms between the biofilm and the effluent. Hence, a microbiological evaluation of the effluent, immediately after flushing, would more likely reflect the microbiological quality of the input water. Biofilm sloughing, the random process in which high numbers of potentially pathogenic micro-organisms detach from the biofilm, is also unlikely to be detected due to the low sampling frequency. These factors, combined with the use of suboptimal growth media, make a risk assessment using HPC questionable [6,7]. In our view, a risk assessment should be based on the ‘proxy’ biofilm sample using, for instance, molecular techniques. Biofilms contain a factor of 102–103 more cells than the effluent, and opportunistic pathogens, such as legionella, reside preferably in the biofilm [8,9]. This alternative sample, taken from the stagnant water column, before flushing and hygiene measures, contains micro-organisms which diffused or migrated from the biofilm, in its relaxed state, into the lumen. Additionally, the sudden increase in shear stress at sampling gives the highest chance of biofilm clumps sloughing off [10]. Whereas more research would be needed to establish new risk thresholds, the ‘proxy’ biofilm sample does give the best prediction of the worst-case scenario to which a patient can be subjected. In our view, this risk assessment, together with strict adherence to infection control guidelines, is needed to guarantee patient safety. If no changes are made, continued use of a post-flush effluent in combination with HPC may result in the dentist believing that the dental unit is safe to use, while in reality exposing vulnerable patients to the risk of contracting pulmonary infections.

Conflict of interest statement

None declared.

Funding sources

None.
  8 in total

1.  An in-vitro dynamic flow model for translational research into dental unit water system biofilms.

Authors:  Michel A Hoogenkamp; Bernd W Brandt; Johannes J de Soet; Wim Crielaard
Journal:  J Microbiol Methods       Date:  2020-02-24       Impact factor: 2.363

2.  Long-term persistence of infectious Legionella with free-living amoebae in drinking water biofilms.

Authors:  Mohamed Shaheen; Candis Scott; Nicholas J Ashbolt
Journal:  Int J Hyg Environ Health       Date:  2019-04-27       Impact factor: 5.840

3.  The microbiological load and microbiome of the Dutch dental unit; 'please, hold your breath'.

Authors:  Michel A Hoogenkamp; Bernd W Brandt; Alexa M G A Laheij; Johannes J de Soet; Wim Crielaard
Journal:  Water Res       Date:  2021-05-06       Impact factor: 11.236

4.  In vitro modeling of dental water line contamination and decontamination.

Authors:  D A Spratt; J Latif; L L Montebugnoli; M Wilson
Journal:  FEMS Microbiol Lett       Date:  2004-06-15       Impact factor: 2.742

5.  Impact of a risk management plan on Legionella contamination of dental unit water.

Authors:  Erica Leoni; Laura Dallolio; Francesca Stagni; Tiziana Sanna; Giovanni D'Alessandro; Gabriela Piana
Journal:  Int J Environ Res Public Health       Date:  2015-02-23       Impact factor: 3.390

6.  Water Quality as a Predictor of Legionella Positivity of Building Water Systems.

Authors:  David Pierre; Julianne L Baron; Xiao Ma; Frank P Sidari; Marilyn M Wagener; Janet E Stout
Journal:  Pathogens       Date:  2019-12-13

Review 7.  Biofilm dispersion: The key to biofilm eradication or opening Pandora's box?

Authors:  Jasper Wille; Tom Coenye
Journal:  Biofilm       Date:  2020-06-01

8.  COVID-19 associated pulmonary aspergillosis.

Authors:  Philipp Koehler; Oliver A Cornely; Bernd W Böttiger; Fabian Dusse; Dennis A Eichenauer; Frieder Fuchs; Michael Hallek; Norma Jung; Florian Klein; Thorsten Persigehl; Jan Rybniker; Matthias Kochanek; Boris Böll; Alexander Shimabukuro-Vornhagen
Journal:  Mycoses       Date:  2020-05-15       Impact factor: 4.377

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.