The microbiological load and microbiome of the Dutch dental unit; 'please, hold your breath'.

Michel A Hoogenkamp1, Bernd W Brandt2, Alexa M G A Laheij3, Johannes J de Soet2, Wim Crielaard2.   

Abstract

Dental unit water systems are prone to biofilm formation. During use of the dental unit, clumps of biofilm slough off and can subsequently be aerosolized and inhaled by both patient and staff, potentially causing infections. The aim of this study was to determine the microbial load and microbiome of dental unit water, in the Netherlands, and the factors influencing these parameters. In total, 226 dental units were sampled and heterotrophic plate counts (HPC) were determined on the traditional effluent sample. Of all dental units, 61% exceeded the recommended microbiological guidelines of 100 colony forming units per milliliter. In addition, the microbiome, with additional q-PCR analysis for specific species, was determined on an effluent sample taken immediately after an overnight stagnancy period, in which the biofilm is in its relaxed state. These relaxed biofilm samples showed that each dental unit had a unique microbiome. Legionella spp., amoeba and fungi were found in 71%, 43% and 98% of all units, respectively. The presence of amoeba was positively associated with nine bacterial biomarkers and correlated positively with bacterial and fungal DNA and Legionella spp. concentrations, but not with HPC. Only when adhering to disinfection protocols, statistically significant effects on the microbial load and microbiome were seen. The relaxed biofilm sample, in combination with molecular techniques gives better insight in the presence of opportunistic pathogens when compared to the heterotrophic plate counts. Infection control measures should focus on biofilm analysis and control in order to guarantee patient safety.
Copyright © 2021 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Amoeba; Biofilm; Dental unit; Fungi; Legionella; Microbiome

Mesh:

Year:  2021        PMID: 34058484     DOI: 10.1016/j.watres.2021.117205

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Assessment of microbiota diversity in dental unit waterline contamination.

Authors:  Yun Dang; Qian Zhang; Jing Wang; Qian Wang; Meng Han; Yuting Niu; Hua Li; Xiue Li
Journal:  PeerJ       Date:  2022-01-06       Impact factor: 3.061

2.  16S rDNA sequencing and metadata of Dutch dental unit water.

Authors:  Michel A Hoogenkamp; Bernd W Brandt; Alexa M G A Laheij; Johannes J de Soet; Wim Crielaard
Journal:  Data Brief       Date:  2021-06-12

3.  The truth is in the eye of the beholder; opportunistic pathogens in the dental unit.

Authors:  M A Hoogenkamp; A M G A Laheij; J J de Soet
Journal:  J Hosp Infect       Date:  2021-06-01       Impact factor: 3.926

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.