Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips.

Takehito Hananouchi1,2, Soshi Uchida3, Yusuke Hashimoto4, Funakoshi Noboru5, Stephen K Aoki6.   

Abstract

Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip labrum. However, hip labrum stiffness in vivo and in cadavers has not been directly compared. The purpose of this study was to compare in vivo and cadaveric hip labrum stiffness during pull-probing with a force sensor. We measured the resistance force of the hip labrum in ten patients during hip arthroscopy (i.e., in vivo) and compared it with ten cadavers, both intact and detached from the acetabulum, using a surgical knife. We confirmed a partial labral tear (i.e., not detached fully from the rim) at an antero-superior potion in all of the patients. The mean highest resistance levels for the hip labrum in the patients (4.7 N) were significantly lower than the intact cadaveric labrum (8.3 N), and slightly higher than the detached labrum (4.2 N). In this study, the stiffness of the cadaveric labrum tissue was similar to that of the in-vivo hip labrum.

Entities:  

Keywords:  cadaver tissue; hip labrum; probing device; tissue resistance

Year:  2021        PMID: 34072623     DOI: 10.3390/biomimetics6020035

Source DB:  PubMed          Journal:  Biomimetics (Basel)        ISSN: 2313-7673


  11 in total

1.  Smart tool for force measurements during knee arthroscopy: in vivo human study.

Authors:  G Chami; J Ward; D Wills; R Phillips; K Sherman
Journal:  Stud Health Technol Inform       Date:  2006

2.  Transferring simulated arthroscopic skills to the operating theatre: a randomised blinded study.

Authors:  N R Howells; H S Gill; A J Carr; A J Price; J L Rees
Journal:  J Bone Joint Surg Br       Date:  2008-04

3.  Probing forces of menisci: what levels are safe for arthroscopic surgery.

Authors:  Gabriëlle J M Tuijthof; Tim Horeman; Matthias U Schafroth; Leendert Blankevoort; Gino M M J Kerkhoffs
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-03       Impact factor: 4.342

4.  A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy.

Authors:  Takehito Hananouchi
Journal:  J Vis Exp       Date:  2020-05-01       Impact factor: 1.355

5.  Proposed Referential Index to Resect Femoroacetabular Cam-Type Impingement During Arthroscopy Using a Cadaveric Hip Model.

Authors:  Shinya Yamasaki; Yusuke Hashimoto; Shozaburo Terai; Junsei Takigami; Shinji Takahashi; Hiroaki Nakamura
Journal:  Arthroscopy       Date:  2015-02-19       Impact factor: 4.772

6.  Hip arthroscopy and the anterolateral portal: avoiding labral penetration and femoral articular injuries.

Authors:  Stephen Kenji Aoki; James Thomas Beckmann; James Derek Wylie
Journal:  Arthrosc Tech       Date:  2012-08-17

7.  Quantitative evaluation of capsular and labral resistances in the hip joint using a probing device.

Authors:  Takehito Hananouchi; Stephen Kenji Aoki
Journal:  Biomed Mater Eng       Date:  2019       Impact factor: 1.300

8.  Systematic review of the current status of cadaveric simulation for surgical training.

Authors:  H K James; A W Chapman; G T R Pattison; D R Griffin; J D Fisher
Journal:  Br J Surg       Date:  2019-10-01       Impact factor: 6.939

9.  Arthroscopic Double Shoelace Capsular Plication Technique for the Treatment of Borderline Hip Dysplasia Associated With Capsular Laxity.

Authors:  Kazuha Kizaki; Akihisa Hatakeyama; Hajime Utsunomiya; Marc J Philippon; Soshi Uchida
Journal:  Arthrosc Tech       Date:  2019-07-30

10.  A Useful Combination of Quantitative Ultrashort Echo Time MR Imaging and a Probing Device for Biomechanical Evaluation of Articular Cartilage.

Authors:  Takehito Hananouchi; Yanjun Chen; Saeed Jerban; Masaru Teramoto; Yajun Ma; Erik W Dorthe; Eric Y Chang; Jiang Du; Darryl D D'Lima
Journal:  Biosensors (Basel)       Date:  2021-02-17
View more
  1 in total

1.  The Resistance Force of the Anterior Cruciate Ligament during Pull Probing Is Related to the Mechanical Property.

Authors:  Takehito Hananouchi; Tomoyuki Suzuki; Erik W Dorthe; Jiang Du; Darryl D D'Lima
Journal:  Bioengineering (Basel)       Date:  2021-12-23
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.