Mechanical performance of the standard Orthofix external fixator.

E Y Chao1, T J Hein.   

Abstract

Static and fatigue tests of the standard Orthofix unilateral external fixator (Orthofix SRL, Verona, Italy) were performed. Under similar fixation configurations, the Orthofix device offered higher bending stiffness in both directions, equal torsional stiffness, and lower axial stiffness when compared to the Hoffmann-Vidal quadrilateral frame with full pins. The bending resistance of the Orthofix ball joint was found to be proportional to its locking cam tightening torque. After applying 2 million loading cycles to the bone ends fixed by the device, the overall stiffness characteristics of the frame did not change significantly. Repetitive manual tightening and loosening of the ball joint caused abrasive wear on the cam and bushing surfaces. The locking position of the cam migrated for a mean of 45 degrees. After 50 cycles of tightening and bending to failure, the ball joint locking strength was reduced by 20% to 25%, but the stiffness did not change. Wear and stripping of the seat of the fixator body locking screw and the pin fixation screw threads were also noted. Based on the test results, the standard Orthofix device could be re-used, but certain fixator components must be inspected and replaced. The ball joint locking cam and fixation screws required periodic tightening during clinical application to prevent loss of frame stiffness under repetitive loading. Modifications of the fixator design are recommended to improve its mechanical performance.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3405906     DOI: 10.3928/0147-7447-19880701-09

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Source of the slippage in the universal joints of the Hoffmann external fixator.

Authors:  F L Drijber; J B Finlay; T K Moroz; C H Rorabeck
Journal:  Med Biol Eng Comput       Date:  1990-01       Impact factor: 2.602

2.  Comparison of the mechanical performance of three types of unilateral, dynamizable external fixators. An experimental study.

Authors:  R A Jaskulka; E Egkher; B Wielke
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

3.  Drug loading and release of Tobramycin from hydroxyapatite coated fixation pins.

Authors:  Mirjam Lilja; Jan Henrik Sörensen; Ulrika Brohede; Maria Astrand; Philip Procter; Jörg Arnoldi; Hartwig Steckel; Maria Strømme
Journal:  J Mater Sci Mater Med       Date:  2013-06-19       Impact factor: 3.896

4.  Prospective Evaluation of Role of Limb Reconstruction System (Rail External Fixator) in Open Fractures and Infected Non-union of Femur.

Authors:  Hemant Singh Chahar; Mayur Gupta; Vinod Kumar; Rohit Yadav; Jaydeep Patel; Chandra Prakash Pal
Journal:  J Orthop Case Rep       Date:  2021
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.