Accuracy of respiratory inductive plethysmographic cross-sectional areas.

H L Watson1, D A Poole, M A Sackner.   

Abstract

The present study was undertaken to evaluate whether the respiratory inductive plethysmograph (RIP) 1) reflects changes of cross-sectional area enclosed by its transducer band in the presence of deformations of shape or whether it 2) has a stable base line. Testing of RIP was carried out with a device incorporating a thermally compensated oscillator and digital demodulatory circuitry. This system, introduced to commerce in 1983, superceded the nonthermal compensated oscillatory and analog demodulator circuitry first used in 1977. Testing the effects of changing cross-sectional area was accomplished by stretching a standard RIP transducer band around wooden dowels placed in holes on a peg board grid to form 23 curved and 5 rectangular shapes. The output voltage from RIP was linear for both the curved and rectangular shapes for changes of cross-sectional area within a physiological range. However, the regression line of voltage vs. cross-sectional area for the rectangular shapes was parallel and slightly displaced from the regression line for the curved shapes due to mutual coupling of inductance in the corners. Base-line drift from a RIP transducer band stretched to enclose an elliptical shape was less than 2.5 mV over a 12-h observation period. Current RIP technology accurately reflects changes of cross-sectional area of physiological shapes and has a stable base line.

Entities:  

Mesh:

Year:  1988        PMID: 3403473     DOI: 10.1152/jappl.1988.65.1.306

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  7 in total

1.  Signal processing technique for non-invasive real-time estimation of cardiac output by inductance cardiography (thoracocardiography).

Authors:  G B Bucklar; V Kaplan; K E Bloch
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

Review 2.  Breathing pattern analysis.

Authors:  M J Tobin
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

3.  Ambulatory abdominal inductance plethysmography: towards objective assessment of abdominal distension in irritable bowel syndrome.

Authors:  M J Lewis; B Reilly; L A Houghton; P J Whorwell
Journal:  Gut       Date:  2001-02       Impact factor: 23.059

4.  Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study.

Authors:  G Roopa Manjunatha; K Rajanna; D Roy Mahapatra; M M Nayak; Uma Maheswari Krishnaswamy; R Srinivasa
Journal:  J Clin Monit Comput       Date:  2013-06-16       Impact factor: 2.502

5.  Continuous non-invasive monitoring of tidal volumes by measurement of tidal impedance in neonatal piglets.

Authors:  Florian Kurth; Fabienne Zinnow; Alexandra Prakapenia; Sabrina Dietl; Stefan Winkler; Sascha Ifflaender; Mario Rüdiger; Wolfram Burkhardt
Journal:  PLoS One       Date:  2011-06-07       Impact factor: 3.240

6.  Time to Lung Volume Stability After Pressure Change During High-Frequency Oscillatory Ventilation.

Authors:  David G Tingay; Nicholas Kiraly; John F Mills; Peter A Dargaville
Journal:  Crit Care Explor       Date:  2021-06-14

7.  Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems.

Authors:  Zhengbo Zhang; Jiewen Zheng; Hao Wu; Weidong Wang; Buqing Wang; Hongyun Liu
Journal:  Sensors (Basel)       Date:  2012-09-27       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.