| Literature DB >> 34022903 |
Shuang Wu1, Xiaolu Shi1, Qiongcheng Chen1, Yixiang Jiang1, Le Zuo1, Lei Wang1, Min Jiang1, Yiman Lin1, Shisong Fang1, Bo Peng1, Weihua Wu1, Hui Liu1, Renli Zhang1, Patrick S L Kwan1, Qinghua Hu2.
Abstract
BACKGROUND: SARS-CoV-2 is a newly emerged coronavirus, causing the coronavirus disease 2019 (COVID-19) outbreak in December, 2019. As drugs and vaccines of COVID-19 remain in development, accurate virus detection plays a crucial role in the current public health crisis. Quantitative real-time reverse transcriptase-polymerase chain reaction (RT-qPCR) kits have been reliably used for detection of SARS-CoV-2 RNA since the beginning of the COVID-19 outbreak, whereas isothermal nucleic acid amplification-based point-of-care automated kits have also been considered as a simpler and rapid alternative. However, as these kits have only been developed and applied clinically within a short timeframe, their clinical performance has not been adequately evaluated to date. We describe a comparative study between a newly developed cross-priming isothermal amplification (CPA) kit (Kit A) and five RT-qPCR kits (Kits B-F) to evaluate their sensitivity, specificity, predictive values and accuracy.Entities:
Keywords: COVID-19; Cross-priming isothermal amplification (CPA); Nucleic acid detection; Real-time reverse transcriptase PCR (RT-qPCR); SARS-CoV-2
Mesh:
Substances:
Year: 2021 PMID: 34022903 PMCID: PMC8140580 DOI: 10.1186/s12941-021-00443-w
Source DB: PubMed Journal: Ann Clin Microbiol Antimicrob ISSN: 1476-0711 Impact factor: 3.944
Parameters for each of the six nucleic acid amplification kits evaluated
| Kit | Target | Volume (uL) | Results interpretation | LOD (copies/mL) | Ref | ||
|---|---|---|---|---|---|---|---|
| sample | RNA | Positive | Negative | ||||
| A | ORF 1ab, N | 500 | / | Tt a ≤ 40 | No Tt value | 1000 | Y |
| B | ORF 1ab, N | / | 5 | Ct ≤ 38 | No Ct value or Ct > 38 | 1000 | N |
| C | ORF 1ab, N | / | 5 | Ct ≤ 35 | Ct > 38 | 500 | N |
| D | ORF 1ab | / | 10 | Ct ≤ 32 | FAM: No Ct value VIC/HEX: Ct ≤ 32 | 100 | Y |
| E | ORF 1ab, N | / | 4 | Ct < 38 | No Ct value or Ct = 45 | 300 | N |
| F | ORF 1ab, N | / | 5 | Ct ≤ 40 | No Ct value or Ct > 40 | 500 | Y |
aTt value is unique to the CPA kit (Kit A) and represents the time when fluorescence value exceeds the threshold line
Performance characteristics of six nucleic acid amplification kits for the detection of SARS-CoV-2 using clinical diagnostic reports as the reference standard
| No. of RT-qPCR result | No. of clinical diagnostic report | Sensitivity | Specificity | PPV | NPV | Diagnostic accuracy | Kappa | ||
|---|---|---|---|---|---|---|---|---|---|
| Positive | Negative | (95% CI) | (95% CI) | (95% CI) | (95% CI) | (95% CI) | |||
| A | Positive | 26 | 0 | 100 (87.1–100) | 100 (87.1–100) | 100 (87.1–100) | 100 (87.1–100) | 100 | 1 |
| Negative | 0 | 26 | (93.1–100) | (p < 0.001) | |||||
| B | Positive | 23 | 0 | 100 (85.7–100) | 89.7 (73.6–96.4) | 88.5 (71.0–96.0) | 100 (87.1–100) | 94.2 | 0.885 |
| Negative | 3 | 26 | (84.4–98.0) | (p < 0.001) | |||||
| C | Positive | 25 | 0 | 100 (86.7–100) | 96.3 (81.7–99.3) | 96.2 (81.1–99.3) | 100 (87.1–100) | 98.1 | 0.962 |
| Negative | 1 | 26 | (89.9–99.7) | (p < 0.001) | |||||
| D | Positive | 18 | 0 | 100 (82.4–100) | 76.5 (60.0–87.6) | 69.2 (50.0–83.5) | 100 (87.1–100) | 84.6 | 0.692 |
| Negative | 8 | 26 | (72.5–92.0) | (p < 0.001) | |||||
| E | Positive | 20 | 0 | 100 (83.9–100) | 81.3 (64.7–91.1) | 76.9 (57.6–89.0) | 100 (87.1–100) | 88.5 | 0.769 |
| Negative | 6 | 26 | (77.0–94.6) | (p < 0.001) | |||||
| F | Positive | 24 | 0 | 100 (86.2–100) | 92.9 (77.4–98.0) | 92.3 (75.9–97.9) | 100 (87.1–100) | 96.15 | 0.923 |
| Negative | 2 | 26 | (87.0–98.9) | (p < 0.001) | |||||
Reproducibility of five RT-qPCR kits (Kits B–F)
| Kit | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | Mean(℃) | SD | CV(%) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B | 34.56 | 33.80 | 34.79 | 35.49 | 34.37 | 33.99 | 35.32 | 33.43 | 33.72 | 34.39 | 0.72 | 2.09 |
| C | 31.72 | 30.38 | 31.90 | 31.61 | 32.41 | 31.85 | 30.35 | 32.31 | 31.61 | 31.57 | 0.74 | 2.34 |
| D | 34.54 | 34.34 | 34.36 | 35.77 | 33.19 | 33.45 | 33.88 | 33.26 | 33.06 | 33.98 | 0.87 | 2.57 |
| E | 32.74 | 31.78 | 33.03 | 32.55 | 31.99 | 32.66 | 32.61 | 32.99 | 33.91 | 32.70 | 0.62 | 1.89 |
| F | 36.15 | 36.54 | 36.34 | 36.87 | 37.22 | 36.81 | 36.29 | 36.61 | 36.95 | 36.64 | 0.35 | 0.95 |