Literature DB >> 34019228

The first real-time intrafraction target position monitoring in pancreas SBRT on an Elekta linear accelerator.

Sankar Arumugam1,2,3, Darren Pavey4, Andrew Oar5, Lois Holloway6,7,8,9, Mark Sidhom10, Mark Lee10.   

Abstract

To perform implanted fiducial based real-time target position monitoring in pancreas stereotactic body radiotherapy (SBRT) using the x-ray imaging system available in a Elekta linear accelerator. An in-house system was developed and clinically utilised for real-time target position monitoring of pancreas SBRT delivery. The developed system was used for the target position monitoring of a pancreas cancer patient treated in free breathing treatment within the study entitled 'Mfolfirinox And STEreotactic Radiotherapy for Patients with Locally Advanced paNcreas cancer (MASTERPLAN): a feasibility study' (ACTRN 12617001642370) consisting of five treatment fractions. The clinical efficacy of the system was studied by performing a retrospective cumulative dose assessment of delivered dose using observed position deviations. The developed system identified two events of baseline shifts in target position that exceeded the accepted tolerance level of ± 3 mm from reference planned position. The retrospective dose assessment study showed that if the position deviations were not detected and corrected for, the maximum dose to duodenum would have increased from 34.6 to 38.8 Gy. The first real-time position monitoring in pancreas SBRT on an Elekta linear accelerator was successfully performed. The developed system was shown to improve the safety and accuracy of SBRT delivery.

Entities:  

Keywords:  Dosimetric impact; Online position monitoring; Position deviation; SBRT

Year:  2021        PMID: 34019228     DOI: 10.1007/s13246-021-01007-0

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  12 in total

1.  In reply to Kumar et al.

Authors:  Hong Ge; Jing Cai; Christopher Kelsey; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-09-01       Impact factor: 7.038

Review 2.  Motion management in gastrointestinal cancers.

Authors:  Hassan Abbas; Bryan Chang; Zhe Jay Chen
Journal:  J Gastrointest Oncol       Date:  2014-06

3.  Quantifying ITV instabilities arising from 4DCT: a simulation study using patient data.

Authors:  Sara St James; Pankaj Mishra; Fred Hacker; Ross I Berbeco; John H Lewis
Journal:  Phys Med Biol       Date:  2012-02-17       Impact factor: 3.609

4.  Impact of 4D-(18)FDG-PET/CT imaging on target volume delineation in SBRT patients with central versus peripheral lung tumors. Multi-reader comparative study.

Authors:  Alin Chirindel; Sonja Adebahr; Daniel Schuster; Tanja Schimek-Jasch; Daniel H Schanne; Ursula Nemer; Michael Mix; Philipp Meyer; Anca-Ligia Grosu; Thomas Brunner; Ursula Nestle
Journal:  Radiother Oncol       Date:  2015-06-23       Impact factor: 6.280

5.  Evaluating and reporting dysphagia in trials of chemoirradiation for head-and-neck cancer.

Authors:  Iris Gluck; Felix Y Feng; Teresa Lyden; Marc Haxer; Francis Worden; Douglas B Chepeha; Avraham Eisbruch
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-09-23       Impact factor: 7.038

6.  Significance of intra-fractional motion for pancreatic patients treated with charged particles.

Authors:  Vania Batista; Daniel Richter; Naved Chaudhri; Patrick Naumann; Klaus Herfarth; Oliver Jäkel
Journal:  Radiat Oncol       Date:  2018-06-25       Impact factor: 3.481

7.  Intrafraction tumor motion during deep inspiration breath hold pancreatic cancer treatment.

Authors:  Chuan Zeng; Weijun Xiong; Xiang Li; Marsha Reyngold; Richard M Gewanter; John J Cuaron; Ellen D Yorke; Tianfang Li
Journal:  J Appl Clin Med Phys       Date:  2019-04-01       Impact factor: 2.102

8.  Using adaptive magnetic resonance image-guided radiation therapy for treatment of inoperable pancreatic cancer.

Authors:  Soumon Rudra; Naomi Jiang; Stephen A Rosenberg; Jeffrey R Olsen; Michael C Roach; Leping Wan; Lorraine Portelance; Eric A Mellon; Anna Bruynzeel; Frank Lagerwaard; Michael F Bassetti; Parag J Parikh; Percy P Lee
Journal:  Cancer Med       Date:  2019-04-01       Impact factor: 4.452

Review 9.  MR-guidance in clinical reality: current treatment challenges and future perspectives.

Authors:  S Corradini; F Alongi; N Andratschke; C Belka; L Boldrini; F Cellini; J Debus; M Guckenberger; J Hörner-Rieber; F J Lagerwaard; R Mazzola; M A Palacios; M E P Philippens; C P J Raaijmakers; C H J Terhaard; V Valentini; M Niyazi
Journal:  Radiat Oncol       Date:  2019-06-03       Impact factor: 3.481

10.  Efficacy and feasibility of stereotactic radiotherapy after folfirinox in patients with locally advanced pancreatic cancer (LAPC-1 trial).

Authors:  Mustafa Suker; Joost J Nuyttens; Ferry A L M Eskens; Brigitte C M Haberkorn; Peter-Paul L O Coene; Erwin van der Harst; Bert A Bonsing; Alexander L Vahrmeijer; J Sven D Mieog; Rutger Jan Swijnenburg; Daphne Roos; B Groot Koerkamp; Casper H J van Eijck
Journal:  EClinicalMedicine       Date:  2019-11-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.