Alin Chirindel1, Sonja Adebahr1, Daniel Schuster2, Tanja Schimek-Jasch2, Daniel H Schanne3, Ursula Nemer4, Michael Mix4, Philipp Meyer4, Anca-Ligia Grosu1, Thomas Brunner1, Ursula Nestle5. 1. Department of Radiation Oncology, University Medical Center Freiburg, Germany; German Cancer Consortium (DKTK), Heidelberg, Partner Site Freiburg, Germany. 2. Department of Radiation Oncology, University Medical Center Freiburg, Germany. 3. Department of Radiation Oncology, Massachusetts General Hospital, Boston, USA. 4. Department of Nuclear Medicine, University Medical Center Freiburg, Germany. 5. Department of Radiation Oncology, University Medical Center Freiburg, Germany; German Cancer Consortium (DKTK), Heidelberg, Partner Site Freiburg, Germany. Electronic address: ursula.nestle@uniklinik-freiburg.de.
Abstract
PURPOSE: Evaluation of the effect of co-registered 4D-(18)FDG-PET/CT for SBRT target delineation in patients with central versus peripheral lung tumors. METHODS: Analysis of internal target volume (ITV) delineation of central and peripheral lung lesions in 21 SBRT-patients. Manual delineation was performed by 4 observers in 2 contouring phases: on respiratory gated 4DCT with diagnostic 3DPET available aside (CT-ITV) and on co-registered 4DPET/CT (PET/CT-ITV). Comparative analysis of volumes and inter-reader agreement. RESULTS: 11 cases of peripheral and 10 central lesions were evaluated. In peripheral lesions, average CT-ITV was 6.2 cm(3) and PET/CT-ITV 8.6 cm(3), resembling a mean change in hypothetical radius of 2 mm. For both CT-ITVs and PET/CT-ITVs inter reader agreement was good and unchanged (0.733 and 0.716; p=0.58). All PET/CT-ITVs stayed within the PTVs derived from CT-ITVs. In central lesions, average CT-ITVs were 42.1 cm(3), PET/CT-ITVs 44.2 cm(3), without significant overall volume changes. Inter-reader agreement improved significantly (0.665 and 0.750; p<0.05). 2/10 PET/CT-ITVs exceeded the PTVs derived from CT-ITVs by >1 ml in average for all observers. CONCLUSION: The addition of co-registered 4DPET data to 4DCT based target volume delineation for SBRT of centrally located lung tumors increases the inter-observer agreement and may help to avoid geographic misses.
PURPOSE: Evaluation of the effect of co-registered 4D-(18)FDG-PET/CT for SBRT target delineation in patients with central versus peripheral lung tumors. METHODS: Analysis of internal target volume (ITV) delineation of central and peripheral lung lesions in 21 SBRT-patients. Manual delineation was performed by 4 observers in 2 contouring phases: on respiratory gated 4DCT with diagnostic 3DPET available aside (CT-ITV) and on co-registered 4DPET/CT (PET/CT-ITV). Comparative analysis of volumes and inter-reader agreement. RESULTS: 11 cases of peripheral and 10 central lesions were evaluated. In peripheral lesions, average CT-ITV was 6.2 cm(3) and PET/CT-ITV 8.6 cm(3), resembling a mean change in hypothetical radius of 2 mm. For both CT-ITVs and PET/CT-ITVs inter reader agreement was good and unchanged (0.733 and 0.716; p=0.58). All PET/CT-ITVs stayed within the PTVs derived from CT-ITVs. In central lesions, average CT-ITVs were 42.1 cm(3), PET/CT-ITVs 44.2 cm(3), without significant overall volume changes. Inter-reader agreement improved significantly (0.665 and 0.750; p<0.05). 2/10 PET/CT-ITVs exceeded the PTVs derived from CT-ITVs by >1 ml in average for all observers. CONCLUSION: The addition of co-registered 4DPET data to 4DCT based target volume delineation for SBRT of centrally located lung tumors increases the inter-observer agreement and may help to avoid geographic misses.
Authors: Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov Journal: Med Phys Date: 2017-05-18 Impact factor: 4.071
Authors: Michael MacManus; Sarah Everitt; Tanja Schimek-Jasch; X Allen Li; Ursula Nestle; Feng-Ming Spring Kong Journal: Transl Lung Cancer Res Date: 2017-12
Authors: Charlotte S van der Vos; Daniëlle Koopman; Sjoerd Rijnsdorp; Albert J Arends; Ronald Boellaard; Jorn A van Dalen; Mark Lubberink; Antoon T M Willemsen; Eric P Visser Journal: Eur J Nucl Med Mol Imaging Date: 2017-07-08 Impact factor: 9.236